Cardiac tamponade in catheter ablation of atrial fibrillation: German-wide analysis of 21 141 procedures in the Helios atrial fibrillation ablation registry (SAFER)

被引:74
作者
Bollmann, Andreas [1 ,2 ]
Ueberham, Laura [1 ,2 ]
Schuler, Ekkehard [3 ]
Wiedemann, Michael [4 ]
Reithmann, Christopher [5 ]
Sause, Armin [6 ]
Tebbenjohanns, Juergen [7 ]
Schade, Anja [8 ]
Shin, Dong-In [9 ]
Staudt, Alexander [10 ]
Zacharzowsky, Udo [11 ]
Ulbrich, Michael [12 ]
Wetzel, Ulrike [13 ]
Neuser, Hans [14 ]
Bode, Kerstin [1 ]
Kuhlen, Ralf [2 ,3 ]
Hindricks, Gerhard [1 ,2 ]
机构
[1] Univ Leipzig, Dept Electrophysiol, Helios Heart Ctr Leipzig, Strumpellstr 39, D-04289 Leipzig, Germany
[2] Leipzig Heart Inst, Leipzig, Germany
[3] Helios Kliniken GmbH, Berlin, Germany
[4] Helios Hosp Berlin Buch, Dept Cardiol, Berlin, Germany
[5] Helios Hosp Munchen West, Dept Internal Med 1, Munich, Germany
[6] Helios Univ Hosp Wuppertal, Dept Cardiol, Wuppertal, Germany
[7] Helios Hosp Hildesheim, Dept Cardiol, Hildesheim, Germany
[8] Helios Hosp Erfurt, Dept Cardiol, Erfurt, Germany
[9] Helios Hosp Krefeld, Dept Cardiol, Krefeld, Germany
[10] Helios Hosp Schwerin, Dept Cardiol & Angiol, Schwerin, Germany
[11] Helios Hosp Bad Saarow, Dept Cardiol, Saarow, Germany
[12] Helios Hosp Siegburg, Dept Cardiol, Siegburg, Germany
[13] Helios Hosp Aue, Dept Cardiol, Aue, Germany
[14] Helios Hosp Plauen, Dept Internal Med 2, Plauen, Germany
来源
EUROPACE | 2018年 / 20卷 / 12期
关键词
Atrial fibrillation; Catheter ablation; Pericardial effusion; Cardiac tamponade; Safety outcomes; Administrative data; COMPLICATION RATES; HEALTH-CARE; VOLUME; QUALITY; RISK; OUTCOMES; IMPACT;
D O I
10.1093/europace/euy131
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Catheter ablation is an established therapy in patients with symptomatic atrial fibrillation (AF) with increasing popularity. Pericardial effusion requiring intervention (PE) is one of the most threatening adverse outcomes. The aim of this study was to examine rates of PE after catheter ablation in a large 'real-world' data set in a German-wide hospital network. Methods and results Using ICD and OPS codes, administrative data of 85 Helios hospitals from 2010 to 2017 was used to identify AF catheter ablation cases [Helios atrial fibrillation ablation registry (SAFER)]. PE occurred in 0.9% of 21 141 catheter ablation procedures. Patients with PE were significantly older, to a higher percentage female, had more frequently hypertension, mild liver disease, diabetes with chronic complications, and renal disease. Low hospital volume (<50 procedures per year) and radiofrequency ablation (vs. cryoablation) were significantly associated with PE. Using two logistic regression models, age, female gender, hypertension, mild liver disease, diabetes with chronic complications, renal disease, low hospital volume, and radiofrequency ablation remained independent predictors for PE. Conclusion Overall PE rate was 0.9%. Predictors for PE occurrence involved factors ascribed to the patient (age, gender, comorbidities), the type of catheter ablation (radiofrequency), and the institution (low-volume centres).
引用
收藏
页码:1944 / 1951
页数:8
相关论文
共 29 条
[1]   Trends and predictors of repeat catheter ablation for atrial fibrillation [J].
Al-Hijji, Mohammed A. ;
Deshmukh, Abhishek J. ;
Yao, Xiaoxi ;
Mwangi, Raphael ;
Sangaralingham, Lindsey R. ;
Friedman, Paul A. ;
Asirvatham, Samuel J. ;
Packer, Douglas L. ;
Shah, Nilay D. ;
Noseworthy, Peter A. .
AMERICAN HEART JOURNAL, 2016, 171 (01) :48-55
[2]  
[Anonymous], 2016, FED REG
[3]   Updated National Multicenter Registry on Procedural Safety of Catheter Ablation for Atrial Fibrillation [J].
Bertaglia, Emanuele ;
Stabile, Giuseppe ;
Pappone, Alessia ;
Themistoclakis, Sakis ;
Tondo, Claudio ;
De Sanctis, Valerio ;
Soldati, Ezio ;
Tritto, Massimo ;
Solimene, Francesco ;
Grimaldi, Massimo ;
Zoppo, Franco ;
Pandozi, Claudio ;
Augello, Giuseppe ;
Calo, Leonardo ;
Pappone, Carlo .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (10) :1069-1074
[4]  
Calkins H, 2017, HEART RHYTHM, V14, pE275, DOI [10.1093/europace/eux274, 10.1016/j.hrthm.2017.05.012, 10.1093/europace/eux275]
[5]   Prevalence and Causes of Fatal Outcome in Catheter Ablation of Atrial Fibrillation [J].
Cappato, Riccardo ;
Calkins, Hugh ;
Chen, Shih-Ann ;
Davies, Wyn ;
Iesaka, Yoshito ;
Kalman, Jonathan ;
Kim, You-Ho ;
Klein, George ;
Natale, Andrea ;
Packer, Douglas ;
Skanes, Allan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (19) :1798-1803
[6]   In-Hospital Complications Associated With Catheter Ablation of Atrial Fibrillation in the United States Between 2000 and 2010 Analysis of 93 801 Procedures [J].
Deshmukh, Abhishek ;
Patel, Nileshkumar J. ;
Pant, Sadip ;
Shah, Neeraj ;
Chothani, Ankit ;
Mehta, Kathan ;
Grover, Peeyush ;
Singh, Vikas ;
Vallurupalli, Srikanth ;
Savani, Ghanshyambhai T. ;
Badheka, Apurva ;
Tuliani, Tushar ;
Dabhadkar, Kaustubh ;
Dibu, George ;
Reddy, Y. Madhu ;
Sewani, Asif ;
Kowalski, Marcin ;
Mitrani, Raul ;
Paydak, Hakan ;
Viles-Gonzalez, Juan F. .
CIRCULATION, 2013, 128 (19) :2104-2112
[7]   Measuring quality in electrophysiology [J].
Friedman, Daniel J. ;
Al-Khatib, Sana M. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 47 (01) :5-10
[8]   Is volume related to outcome in health care? A systematic review and methodologic critique of the literature [J].
Halm, EA ;
Lee, C ;
Chassin, MR .
ANNALS OF INTERNAL MEDICINE, 2002, 137 (06) :511-520
[9]   Impact of Structural Heart Disease on the Acute Complication Rate in Atrial Fibrillation Ablation: Results from the German Ablation Registry [J].
Hoffmann, Boris A. ;
Kuck, Karl-Heinz ;
Andresen, Dietrich ;
Spitzer, Stefan G. ;
Hoffmann, Ellen ;
Schumacher, Burghard ;
Eckardt, Lars ;
Brachmann, Johannes ;
Becker, Ruediger ;
Steven, Daniel ;
Rostock, Thomas ;
Juenger, Claus ;
Senges, Jochen ;
Willems, Stephan .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (03) :242-249
[10]   Back to the Future: Volume as a Quality Metric [J].
Jha, Ashish K. .