Optimum Configuration of Cannulated Compression Screws for the Fixation of Unstable Femoral Neck Fractures: Finite Element Analysis Evaluation

被引:32
作者
Li, Jiantao [1 ]
Wang, Menglin [2 ]
Zhou, Jianfeng [3 ]
Han, Lin [4 ]
Zhang, Hao [1 ]
Li, Chen [5 ]
Li, Lianting [6 ]
Hao, Ming [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Orthopaed, 28 Fuxing Rd, Beijing 100853, Peoples R China
[2] Peking Univ, Hosp 3, Dept Otolaryngol Head & Neck Surg, Beijing 100191, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Dept Emergency, 28 Fuxing Rd, Beijing 100853, Peoples R China
[4] Second Mil Med Univ, Grad Sch, Shanghai 200433, Peoples R China
[5] Tianjin Hosp, Dept Orthopaed, 406 Jiefang Rd, Tianjin 300211, Peoples R China
[6] Third Peoples Hosp Qingdao, Dept Orthopaed, 29 Yongping Rd, Qingdao 266041, Peoples R China
关键词
COMPOSITE FEMUR; REMOVAL; COMPLICATIONS; DEVICES; RISK;
D O I
10.1155/2018/1271762
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objectives. In the present study, we evaluated the mechanical outcome of different configurations of cannulated compression screws for the fixation of Pauwels type III femoral neck fracture and the stress distribution around the holes corresponding to fixation protocol after screws removal. Methods. The Pauwels type III of femoral neck fracture was created in 3-matic software and the models of cannulated compression screws were constructed using UG-NX software. Five fixation systems were assembled to the fracture models. Abaqus software was used to perform the process of finite element analysis. Values of stress distribution, maximum stress, model principal strains of proximal fragment, and stress distribution around the holes of femur model were recorded. Results. Stress of cannulated compression screws was intensely focused on the middle area of the screw near the fragment of each group. Inverted triangle model showed the highest peak stress on screws under different phases of load. Each screw dispersed some stresses, but at least one underwent the peak stress. Fracture model fixed by inverted triangle configuration showed the lowest volume of yielding strain in the proximal fragment. The area of higher stress around the holes was largest after triangle screws removal when compared with other four models. Conclusions. Our study indicated that different cannulated compression screws fixation configurations for the unstable femoral neck fractures showed the different mechanical efficiency. Inverted triangular configuration showed the mechanical advantage and being less likely to cutout. The fixation strategy of triangle configuration was least recommended if patients tended to remove the implants.
引用
收藏
页数:10
相关论文
共 27 条
  • [1] Biases in a randomized comparison of three types of screw fixation in displaced femoral neck fractures
    Alho, A
    Austdal, S
    Benterud, JG
    Blikra, G
    Lerud, P
    Raugstad, TS
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (05): : 463 - 468
  • [2] IMPLANT HOLDING POWER OF THE FEMORAL-HEAD - A CADAVER STUDY OF FRACTURE SCREWS
    BENTERUD, JG
    HUSBY, T
    GRAADAHL, O
    ALHO, A
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01): : 47 - 49
  • [3] Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis
    Chen, WP
    Tai, CL
    Shih, CH
    Hsieh, PH
    Leou, MC
    Lee, MS
    [J]. CLINICAL BIOMECHANICS, 2004, 19 (03) : 255 - 262
  • [4] Crowell RR, 1985, T 31 ORTHOP RES SOC, V10
  • [5] Estrada LS, 2002, CLIN ORTHOP RELAT R, P110
  • [6] Mechanical Evaluation of Large-Size Fourth-Generation Composite Femur and Tibia Models
    Gardner, Matthew P.
    Chong, Alexander C. M.
    Pollock, Anthony G.
    Wooley, Paul H.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) : 613 - 620
  • [7] Does bone compaction around the helical blade of a proximal femoral nail antirotation (PFNA) decrease the risk of cut-out? A SUBJECT-SPECIFIC COMPUTATIONAL STUDY
    Goffin, J. M.
    Pankaj, P.
    Simpson, A. H. R. W.
    Seil, R.
    Gerich, T. G.
    [J]. BONE & JOINT RESEARCH, 2013, 2 (05): : 79 - 83
  • [8] The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw: A subject-specific finite element study
    Goffin, Jerome M.
    Pankaj, Pankaj
    Simpson, A. Hamish
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (04) : 596 - 600
  • [9] Experimental validation of finite element model for proximal composite femur using optical measurements
    Grassi, Lorenzo
    Vaananen, Sami P.
    Yavari, Saber Amin
    Weinans, Harrie
    Jurvelin, Jukka S.
    Zadpoor, Amir A.
    Isaksson, Hanna
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 21 : 86 - 94
  • [10] Subtrochanteric femoral fracture following removal of screw for slipped capital femoral epiphysis
    Hafez, MA
    Templeton, PA
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (09): : 953 - 953