In vitro assessment of heart valve bioprostheses by cardiovascular magnetic resonance: four-dimensional mapping of flow patterns and orifice area planimetry

被引:16
作者
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ]
Dieringer, Matthias A. [1 ,2 ]
Greiser, Andreas [3 ]
Schulz-Menger, Jeanette [1 ,2 ]
机构
[1] Med Univ Berlin, Working Grp Cardiovasc Magnet Resonance Imaging, Expt & Clin Res Ctr, D-13125 Berlin, Germany
[2] HELIOS Klinikum Berlin Buch, Dept Cardiol & Nephrol, D-13125 Berlin, Germany
[3] Siemens AG, Healthcare Sect, Erlangen, Germany
关键词
Heart valves; Heart valve prosthesis; Magnetic resonance imaging; Blood flow velocity; Hemodynamics; SMALL AORTIC ANNULUS; PHASE-CONTRAST MRI; PERICARDIAL BIOPROSTHESIS; CLINICAL-OUTCOMES; BLOOD-FLOW; HANCOCK-II; REPLACEMENT; PROSTHESES; POSITION; STANDARDS;
D O I
10.1016/j.ejcts.2010.12.040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The hemodynamics in proximity to stented aortic bioprostheses still differ from that under physiological conditions. This may prevent desired cardiac remodeling and promote aortic diseases. Further improvements in prosthetic technology require an accurate survey of the flow conditions on the prosthetic level and in the ascending aorta. Cardiovascular magnetic resonance (CMR) may have the potential to provide more information by determining the prosthetic orifice area and visualizing the intravascular flow dynamics. We tested the feasibility to better characterize the hemodynamics of various stented bioprostheses in a pulsatile flow phantom by using CMR. Methods: The custom-made model consisting of a commercially available pump generating pulsatile flow, a tube system filled with a glycerin-water mixture, and a handcrafted bulbar-shaped cylinder holding the bioprostheses and simulating the aortic root, was located in a clinical 1.5 T CMR system. In this study, 10 stented aortic bioprostheses were investigated (Perimount (R) 21, 23; Mitroflow (R) 19, 25; Hancock (R) 21, 23, 25; Mosaic (R) 21; Epic Supra (R) 21, 23). The prosthetic orifice area was visualized using steady-state free-precession cine imaging (spatial/temporal resolution 1.3 x 1.3 x 5 mm(3)/ 29 ms), quantified by manual planimetry and compared with published transthoracic echocardiographic data. Time-resolved three-dimensional phase-contrast flow mapping (1.8 x 1.8 x 3 mm(3)/45 ms) was applied to analyze the transprosthetic flow pattern. Results: Visualization of the prosthetic orifice area and the transprosthetic flow pattern was feasible in all prostheses. All orifice areas obtained by CMR in vitro were within one standard deviation of the mean of the published reference values obtained by echocardiography in vivo. Turbulent flow with vortex formation occurred both in proximity to the prosthesis and on the 'ascending aortic' level. Larger prosthetic sizes led to decreased flow velocities, but not mandatorily to less turbulences. Conclusions: CMR allowed for a detailed interrogation of the fluid dynamics of various heart valve bioprostheses in a pulsatile flow model. It is an attractive tool to define proprietary reference values of the orifice area under standardized conditions and provides novel information regarding the flow pattern in proximity to the prosthesis. (C) 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:736 / 742
页数:7
相关论文
共 25 条
[1]   Opening and closing kinematics of fresh and calcified aortic valve prostheses: An in vitro study [J].
Bakhtiary, Farhad ;
Dzemali, Omer ;
Steinseiffer, Ulrich ;
Schmitz, Christof ;
Glasmacher, Birgit ;
Moritz, Anton ;
Kleine, Peter .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (03) :657-662
[2]  
Bleiziffer S, 2009, J HEART VALVE DIS, V18, P95
[3]   Carpentier-Edwards Perimount Magna valve versus Medtronic Hancock II: A matched hemodynamic comparison [J].
Borger, Michael A. ;
Nette, A. Franka ;
Maganti, Manjula ;
Feindel, Christopher M. .
ANNALS OF THORACIC SURGERY, 2007, 83 (06) :2054-2059
[4]   Hemodynamic and clinical outcomes with the Biocor valve in the aortic position: An 8-year experience [J].
Bottio, T ;
Rizzoli, G ;
Thiene, G ;
Nesseris, G ;
Casarotto, D ;
Gerosa, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (06) :1616-1623
[5]  
Bottio Tomaso, 2008, Interact Cardiovasc Thorac Surg, V7, P750, DOI 10.1510/icvts.2008.182469
[6]   Hemodynamic comparison of Bioprostheses for complete supra-annular position in patients with small aortic annulus [J].
Botzenhardt, F ;
Eichinger, WB ;
Bleiziffer, S ;
Guenzinger, R ;
Wagner, IM ;
Bauernschmitt, R ;
Lange, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (12) :2054-2060
[7]   Mid-term hemodynamic and clinical results of the stented porcine Medtronic Mosaic valve in aortic position [J].
Botzenhardt, F ;
Gansera, B ;
Kemkes, BM .
THORACIC AND CARDIOVASCULAR SURGEON, 2004, 52 (01) :34-41
[8]   Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: Changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database [J].
Brown, James M. ;
O'Brien, Sean M. ;
Wu, Changfu ;
Sikora, Jo Ann H. ;
Griffith, Bartley P. ;
Gammie, James S. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :82-90
[9]   Late results of heart valve replacement with the Hancock II bioprosthesis [J].
David, TE ;
Ivanov, J ;
Armstrong, S ;
Feindel, CM ;
Cohen, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (02) :268-278
[10]   Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis [J].
Dellgren, G ;
David, TE ;
Raanani, E ;
Armstrong, S ;
Ivanov, J ;
Rakowski, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (01) :146-154