Three-dimensional electrode displacement elastography using the siemens C7F2 foursight four-dimensional ultrasound transducer

被引:46
作者
Bharat, Shyam [1 ,2 ]
Fisher, Ted G. [1 ]
Varghese, Tomy [1 ,2 ]
Hall, Timothy J. [1 ]
Jiang, Jingfeng [1 ]
Madsen, Ernest L. [1 ]
Zagzebski, James A. [1 ]
Lee, Fred T., Jr. [3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
关键词
three-dimensional (3D); four-dimensional (4D); ablation; compression; displacement; elastography; elastogram; elasticity; elasticity imaging; electrode displacement; radio-frequency ablation; strain; strain imaging; ultrasound;
D O I
10.1016/j.ultrasmedbio.2008.01.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Because ablation therapy alters the elastic modulus of tissues, emerging strain imaging methods may enable clinicians for the first time to have readily available, cost-effective, real-time guidance to identify the location and boundaries of thermal lesions. Electrode displacement elastography is a method of strain imaging tailored specifically to ultrasound-guided electrode-based ablative therapies (e.g., radio-frequency ablation). Here tissue deformation is achieved by applying minute perturbations to the unconstrained end of the treatment electrode, resulting in localized motion around the end of the electrode embedded in tissue. In this article, we present a method for three-dimensional (3D) elastographic reconstruction from volumetric data acquired using the C7F2 fourSight four-dimensional ultrasound transducer, provided by Siemens Medical Solutions USA, Inc. (Issaquah, WA, USA). Lesion reconstruction is demonstrated for a spherical inclusion centered in a tissue-mimicking phantom, which simulates a thermal lesion embedded in a normal tissue background. Elastographic reconstruction is also performed for a thermal lesion created in vitro in canine liver using radio-frequency ablation. Postprocessing is done on the acquired raw radio-frequency data to form surface-rendered 3D elastograms of the inclusion. Elastographic volume estimates of the inclusion compare reasonably well with the actual known inclusion volume, with 3D electrode displacement elastography slightly underestimating the true inclusion volume.
引用
收藏
页码:1307 / 1316
页数:10
相关论文
共 33 条
[1]  
BHARAT S, 2005, P 4 INT C ULTR MEAS, P58
[2]  
BHARAT S, 2007, MED PHYS UNPUB
[3]   Contrast-transfer improvement for electrode displacement elastography [J].
Bharat, Shyam ;
Varghese, Tomy .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (24) :6403-6418
[4]  
Boctor E, 2006, LECT NOTES COMPUT SC, V4191, P405
[5]   Acoustic radiation force impulse imaging of thermally- and chemically-induced lesions in soft tissues: Preliminary ex vivo results [J].
Fahey, BJ ;
Nightingale, KR ;
Stutz, DL ;
Trahey, GE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (03) :321-328
[6]   Delta-sigma oversampled ultrasound beamformer with dynamic delays [J].
Freeman, SR ;
Quick, MK ;
Morin, MA ;
Anderson, RC ;
Desilets, CS ;
Linnenbrink, TE ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (02) :320-332
[7]  
Fung Y. G., 1981, BIOMECHANICAL PROPER
[8]   Tumor ablation with radio-frequency energy [J].
Gazelle, GS ;
Goldberg, SN ;
Solbiati, L ;
Livraghi, T .
RADIOLOGY, 2000, 217 (03) :633-646
[9]   Thermal ablation therapy for focal malignancy: A unified approach to underlying principles, techniques, and diagnostic imaging guidance [J].
Goldberg, SN ;
Gazelle, GS ;
Mueller, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :323-331
[10]   Phantom materials for elastography [J].
Hall, TJ ;
Bilgen, M ;
Insana, MF ;
Krouskop, TA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1355-1365