Contact atomic force microscopy using piezoresistive cantilevers in load force modulation mode

被引:7
|
作者
Biczysko, P. [1 ]
Dzierka, A. [1 ]
Jozwiak, G. [1 ]
Rudek, M. [1 ]
Gotszalk, T. [1 ]
Janus, P. [2 ]
Grabiec, P. [2 ]
Rangelow, I. W. [3 ]
机构
[1] Wroclaw Univ Technol, Fac Microsyst Elect & Photon, Wroclaw, Poland
[2] Inst Electr Mat Technol, Warsaw, Poland
[3] Ilmenau Univ Technol, Inst Micro & Nanoelect, Dept Micro & Nanoelectr Syst, Fac Elect Engn & Informat Technol, Gustav Kirchhoff Str 1, D-98693 Ilmenau, Germany
关键词
Atomic force microscopy; Piezoresistive probe; Drift free scanning; Load force modulation; PROBE; CALIBRATION; RESOLUTION; ACTUATOR;
D O I
10.1016/j.ultramic.2017.09.002
中图分类号
TH742 [显微镜];
学科分类号
摘要
Scanning probe microscopy (SPM) encompasses several techniques for imaging of the physical and chemical material properties at nanoscale. The scanning process is based on the detection of the deflection of the cantilever, which is caused by near field interactions, while the tip runs over the sample's surface. The variety of deflection detection methods including optical, piezoresistive, piezoelectric technologies has been developed and applied depending on the measurement mode and measurement environment. There are many advantages (compactness, vacuum compatibility, etc.) of the piezoresistive detection method, which makes it very attractive for almost all SPM experiments. Due to the technological limitations the stiffness of the piezoresistive beams is usually higher than the stiffness of the cantilever detected using optical methods. This is the basic constraint for the application of the piezoresistive beams in contact mode (CM) atomic force microscopy (AFM) investigations performed at low load forces (usually less than 20 nN). Drift of the deflection signal, which is related to thermal fluctuations of the measurement setup, causes that the microscope controller compensates the fluctuations instead of compensating the strength of tip-surface interactions. Therefore, it is quite difficult to keep near field interaction precisely at the setpoint level during the whole scanning process. This can lead to either damage of the cantilever's tip and material surface or loosing the contact with the investigated sample and making the measurement unreliable. For these reasons, load force modulation (LoFM) scanning mode, in which the interaction at the tip is precisely controlled at every point of the sample surface, is proposed to enable precise AFM surface investigations using the piezoresistive cantilevers. In this article we describe the developed measurement algorithm as well as proposed and introduced hardware and software solutions. The results of the experiments confirm strong reduction of the AFM entire setup drift. The results demonstrating contactless tip lateral movements are presented. It is common knowledge that such a scanning reduces tip wear. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 208
页数:10
相关论文
共 50 条
  • [21] Force spectroscopy based on temperature controlled atomic force microscope head using piezoresistive cantilevers
    Musevic, I
    Kocevar, K
    Krzic, U
    Carbone, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (04):
  • [22] Vibration analysis of atomic force microscope cantilevers in contact resonance force microscopy using Timoshenko beam model
    Xilong Zhou
    Pengfei Wen
    Faxin Li
    Acta Mechanica Solida Sinica, 2017, 30 (05) : 520 - 530
  • [23] Vibration analysis of atomic force microscope cantilevers in contact resonance force microscopy using Timoshenko beam model
    Xilong Zhou
    Pengfei Wen
    Faxin Li
    Acta Mechanica Solida Sinica, 2017, 30 : 520 - 530
  • [24] Vibration analysis of atomic force microscope cantilevers in contact resonance force microscopy using Timoshenko beam model
    Zhou, Xilong
    Wen, Pengfei
    Li, Faxin
    ACTA MECHANICA SOLIDA SINICA, 2017, 30 (05) : 520 - 530
  • [25] Noise in piezoresistive atomic force microscopy
    Hansen, O
    Boisen, A
    NANOTECHNOLOGY, 1999, 10 (01) : 51 - 60
  • [26] Low temperature force microscopy based on piezoresistive cantilevers operating at a higher flexural mode
    A. Volodin
    C. Van Haesendonck
    Applied Physics A, 1998, 66 : S305 - S308
  • [27] Atomic force microscopy cantilevers for sensitive lateral force detection
    Kageshima, M
    Ogiso, H
    Nakano, S
    Lantz, MA
    Tokumoto, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (6B): : 3958 - 3961
  • [28] Atomic force microscopy cantilevers for sensitive lateral force detection
    Kageshima, Masami
    Ogiso, Hisato
    Nakano, Shizuka
    Lantz, Mark A.
    Tokumoto, Hiroshi
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (6 B): : 3958 - 3961
  • [29] Low temperature force microscopy based on piezoresistive cantilevers operating at a higher flexural mode
    Volodin, A
    Van Haesendonck, C
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1): : S305 - S308
  • [30] Nanomechanical measurements on polymers using contact mode atomic force microscopy
    Lemoine, P
    McLaughlin, JM
    THIN SOLID FILMS, 1999, 339 (1-2) : 258 - 264