Application of Monte Carlo simulation to 134Cs standardization by means of 4πβ-γ coincidence system

被引:11
作者
Takeda, MN [1 ]
Dias, MD
Koskinas, MF
机构
[1] IPEN CNEN SP, Div Nucl Phys, Nucl Metrol Lab CRPq, BR-05508000 Sao Paulo, Brazil
[2] Univ Santo Amaro UNISA, Sao Paulo, Brazil
关键词
coincidence; Cs-134; Monte Carlo; simulation; standardization;
D O I
10.1109/TNS.2005.856772
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The methodology recently developed by the Nuclear Metrology Laboratory (LMN) from IPEN, in Sao Paulo, Brazil, for simulating all detection processes in a 4 pi(beta,X) - gamma coincidence system by means of the Monte Carlo technique is described. This procedure makes possible to predict the behavior of the observed activity as a function of the 4 pi beta detector efficiency. The present paper describes its application to the standardization of a typical beta-gamma radionuclide, namely Cs-134. In this approach, information contained in the decay scheme is used for determining the contribution of all radiations emitted by the selected radionuclide to the measured spectra of each detector. This simulation yields the shape of the coincidence spectrum, allowing the choice of suitable gamma-ray energies for which the activity can be obtained with maximum accuracy. The theoretical work applies the MCNP Monte Carlo code to a gas-flow proportional counter with 4 pi detection geometry, coupled to a pair of NaI(TI) crystals. The calculated extrapolation curve showed good agreement when compared to experimental values obtained at the LMN of IPEN.
引用
收藏
页码:1716 / 1720
页数:5
相关论文
共 18 条
[1]   Coincidence system for standardization of radionuclides using a 4π plastic scintillator detector [J].
Baccarelli, AM ;
Dias, MS ;
Koskinas, MF .
APPLIED RADIATION AND ISOTOPES, 2003, 58 (02) :239-244
[2]   EFFICIENCY EXTRAPOLATION METHOD IN COINCIDENCE COUNTING [J].
BAERG, AP .
NUCLEAR INSTRUMENTS & METHODS, 1973, 112 (1-2) :143-150
[3]   ABSOLUTE MEASUREMENT OF RADIOACTIVITY [J].
BAERG, AP .
METROLOGIA, 1967, 3 (04) :105-&
[4]  
Baerg AP., 1966, Metrologia, V2, P23, DOI [10.1088/0026-1394/2/1/006, DOI 10.1088/0026-1394/2/1/006]
[5]  
Campion P.J., 1959, Int. J. Appl. Radiat. Isot., V4, P232
[6]  
DIAS MS, 1978, THESIS U SAO PAULO S
[7]  
Evans R D, 1955, ATOMIC NUCL, P548
[8]   MESURE ABSOLUE DE LACTIVITE DES RADIONUCLIDES PAR LA METHODE DES COINCIDENCES BETA-GAMMA A LAIDE DE DETECTEURS DE GRANDE EFFICACITE - ETUDE DES COINCIDENCES INSTRUMENTALES [J].
GANDY, A .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1961, 11 (01) :75-&
[9]   MESURE ABSOLUE DE LACTIVITE DES RADIONUCLIDES PAR LA METHODE DES COINCIDENCES BETA-GAMMA A LAIDE DE DETECTEURS DE GRANDE EFFICACITE - CORRECTIONS DE TEMPS MORTS [J].
GANDY, A .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1962, 13 (SEP) :501-&
[10]   4PI-BETA-GAMMA COINCIDENCE COUNTING FOR CALIBRATION OF NUCLIDES WITH COMPLEX DECAY SCHEMES [J].
HOUTERMANS, H ;
MIGUEL, M .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1962, 13 (MAR) :137-&