Steady-state operating conditions of very long EHVAC cable lines

被引:24
|
作者
Gatta, F. M. [1 ]
Geri, A. [1 ]
Lauria, S. [1 ]
Maccioni, M. [1 ]
机构
[1] Univ Roma La Sapienza, Dept Astronaut Elect & Energet Engn, I-00184 Rome, Italy
关键词
EHVAC cables; Power transmission; Cable ampacity; Shunt compensation; Voltage and reactive power control; Temporary overvoltages;
D O I
10.1016/j.epsr.2011.03.011
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the present paper the authors investigate steady-state capabilities of very long EHVAC underground cable lines, without intermediate compensating stations, installed in meshed networks. Analytical formulas of cable length-loading relationship are presented to this purpose. The study shows that, in optimal operating conditions, most of the ampacity of such long underground cable lines can be exploited for active power transmission. Non-optimal operating envelopes are studied, showing the effect of terminal voltages and line losses on cable utilization and evidencing limited derating under realistic hypotheses. A parametric analysis of loading limits and possible voltage violations along the cable is shown: a simple criterion for optimal utilization of lossy cable lines is also proposed. Line-end shunt compensation requirements for integration of long EHVAC cable lines in transmission networks are then specified. Studies performed for both ideal and real cables and shunt reactors show that active power transmission of 100 km long, 400 kV-50 Hz underground cable lines can attain 90% of their thermal limit, without intermediate compensating stations. Excess reactive power and temporary overvoltages are effectively controlled by line-end compensation around 90%. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1525 / 1533
页数:9
相关论文
共 50 条
  • [1] Steady-state operating conditions of very long EHVAC cable lines: Two case studies
    Gatta, F. M.
    Geri, A.
    Lauria, S.
    Maccioni, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 83 (01) : 160 - 169
  • [2] Steady-state Operation of Very Long EHV AC Cable Lines
    Colla, L.
    Gatta, F. M.
    Geri, A.
    Lauria, S.
    Maccioni, M.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 1569 - +
  • [3] Characterization of the Steady-State Operating Conditions of Tethered Coaxial Turbines
    Williams, Vinson Oliver
    Bryant, Samuel
    Agrawal, Saurabh
    Mazzoleni, Andre P.
    Granlund, Kenneth
    Ramaprabhu, Praveen
    Bryant, Matthew
    2022 OCEANS HAMPTON ROADS, 2022,
  • [4] A simplified steady-state characterization of long AC transmission lines
    Carlos del-Pino-Lopez, Juan
    Cruz-Romero, Pedro
    Gomez-Exposito, Antonio
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [5] CURRENT SHARING IN AN INSULATED MULTISTRAND CABLE IN TRANSIENT AND STEADY-STATE CURRENT CONDITIONS
    FAIVRE, D
    TURCK, B
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (01) : 1048 - 1051
  • [6] Calculating Steady-State Operating Conditions for DFIG-Based Wind Turbines
    Wu, Meng
    Xie, Le
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2018, 9 (01) : 293 - 301
  • [7] CALCULATION OF DYNAMIC RANGE OF A SEMICONDUCTOR LASER UNDER STEADY-STATE OPERATING CONDITIONS
    NOVIKOV, AA
    SUKHOV, G
    RADIO ENGINEERING AND ELECTRONIC PHYSICS-USSR, 1970, 15 (10): : 1924 - &
  • [8] Steady-state cornering equilibria and stabilisation for a vehicle during extreme operating conditions
    Velenis E.
    Frazzoli E.
    Tsiotras P.
    International Journal of Vehicle Autonomous Systems, 2010, 8 (2-4) : 217 - 241
  • [9] Electromagnetic Parameters of Screened Current Conductors in Steady-State Operating Conditions.
    Meerovich, E.A.
    Chal'yan, K.M.
    1600,
  • [10] Steady-state modelling of a HT-PEMFC under various operating conditions
    Rigal, S.
    Turpin, C.
    Jaafar, A.
    Chadourne, N.
    Horde, T.
    Jollys, J. -B.
    PROCEEDINGS OF THE 2019 IEEE 12TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2019, : 439 - 445