A Glucose Biosensor Based on Direct Electron Transfer of Glucose Oxidase on PEDOT Modified Microelectrode

被引:43
作者
Chen, Junhao [1 ]
Zheng, Xiaoyuan [1 ]
Li, Yulin [1 ]
Zheng, Haitao [1 ]
Liu, Yanjun [1 ]
Suye, Shin-ichiro [2 ]
机构
[1] Tiangong Univ, Sch Chem & Chem Engn, Tianjin 300380, Peoples R China
[2] Univ Fukui, Grad Sch Engn, Dept Appl Chem & Biotechnol, Fukui 9108507, Japan
关键词
WALLED CARBON NANOTUBES; DIRECT ELECTROCHEMISTRY; HYDROGEN-PEROXIDE; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); POLYPYRROLE; REDOX; FABRICATION; ADSORPTION; COMPOSITE; MECHANISM;
D O I
10.1149/1945-7111/ab7e26
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Implantable glucose biosensor based on poly (3,4-ethylenedioxythiophene) (PEDOT) modified carbon fiber (CF) microelectrode was fabricated for the first time. Main appeal of this work was the immobilization of glucose oxidase (GOx) on PEDOT film by electrostatic interaction, which resulted in the direct electron transfer (DET) between the active sites of enzyme and electrode in the help of PEDOT. The sensor exhibited selective response to glucose in the presence of some common interference. The biosensor operates at a low potential of -0.65 V vs Ag/AgCl, and the amperometric response was linear over range from 0.5 mM to 15 mM for glucose with a sensitivity of 8.5 mu A.cm(-2).mM(-1). The Michaelis-Menten constant was calculated as 6.5 mM, and the sensor retain 81.3% sensitivity after 60 d storage. Moreover, the extremely simple process of DET construction could be potentially extended for the mass production. (C) 2020 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.
引用
收藏
页数:8
相关论文
共 53 条
[1]   Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode [J].
Amatatongchai, Maliwan ;
Sroysee, Wongduan ;
Chairam, Sanoe ;
Nacapricha, Duangjai .
TALANTA, 2017, 166 :420-427
[2]   Towards direct enzyme wiring: a theoretical investigation of charge carrier transfer mechanisms between glucose oxidase and organic semiconductors [J].
Bagdziunas, Gintautas ;
Ramanavicius, Arunas .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2019, 21 (06) :2968-2976
[3]   New CNT/poly(brilliant green) and CNT/poly(3,4-ethylenedioxythiophene) based electrochemical enzyme biosensors [J].
Barsan, Madalina M. ;
Pifferi, Valentina ;
Falciola, Luigi ;
Brett, Christopher M. A. .
ANALYTICA CHIMICA ACTA, 2016, 927 :35-45
[4]   Identifying the n=2 reaction mechanism of FAD through voltammetric simulations [J].
Cable, M ;
Smith, ET .
ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) :299-306
[5]   An amperometric glucose biosensor based on PEDOT nanofibers [J].
Cetin, Merih Zeynep ;
Camurlu, Pinar .
RSC ADVANCES, 2018, 8 (35) :19724-19731
[6]   Direct electron transfer of glucose oxidase and dual hydrogen peroxide and glucose detection based on water-dispersible carbon nanotubes derivative [J].
Chen, Hsiao-Chien ;
Tu, Yi-Ming ;
Hou, Chung-Che ;
Lin, Yu-Chen ;
Chen, Ching-Hsiang ;
Yang, Kuang-Hsuan .
ANALYTICA CHIMICA ACTA, 2015, 867 :83-91
[7]   High Catalytic Activity of Au-PEDOT Nanoflowers toward Electrooxidation of Glucose [J].
Dash, Sthitaprajna ;
Munichandraiah, N. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (11) :H858-H865
[8]   Improved glucose label-free biosensor with layer-by-layer architecture and conducting polymer poly(3,4-ethylenedioxythiophene) [J].
David, Melinda ;
Barsan, Madalina M. ;
Brett, Christopher M. A. ;
Florescu, Monica .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 :3227-3234
[9]  
de Levie R., 1963, Electrochim. Acta, V8, P751, DOI [DOI 10.1016/0013-4686(63)80042-0, 10.1016/0013-4686(63)80042-0]
[10]   Polypyrrole nanotube array sensor for enhanced adsorption of glucose oxidase in glucose biosensors [J].
Ekanayake, E. M. I. Mala ;
Preethichandra, D. M. G. ;
Kaneto, Keiichi .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (01) :107-113