3D computed tomography using a microfocus X-ray source: Analysis of artifact formation in the reconstructed images using simulated as well as experimental projection data

被引:18
|
作者
Krimmel, S
Stephan, J
Baumann, J
机构
[1] Tech Univ Munich, Phys Dept E21, D-85748 Garching, Germany
[2] Siemens AG, Corp Technol, D-81730 Munich, Germany
关键词
tomography; feldkamp; simulation; X-ray; nondestructive testing; artifacts;
D O I
10.1016/j.nima.2005.01.171
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The scope of this contribution is to identify and to quantify the influence of different parameters on the formation of image artifacts in X-ray computed tomography (CT) resulting for example, from beam hardening or from partial lack of information using 3D cone beam CT. In general, the reconstructed image quality depends on a number of acquisition parameters concerning the X-ray source (e.g. X-ray spectrum), the geometrical setup (e.g. cone beam angle), the sample properties (e.g. absorption characteristics) and the detector properties. While it is difficult to distinguish the influence of different effects clearly in experimental projection data, they can be selected individually with the help of simulated projection data by varying the parameter set. The reconstruction of the 3D data set is performed with the filtered back projection algorithm according to Feldkamp, Davis and Kress for experimental as well as for simulated projection data. The experimental data are recorded with an industrial microfocus CT system which features a focal spot size of a few micrometers and uses a digital flat panel detector for data acquisition. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:399 / 407
页数:9
相关论文
共 50 条
  • [1] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    Roth, Don
    MATERIALS EVALUATION, 2020, 78 (02) : 203 - 212
  • [2] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    Roth, Don (don.roth@bhge.com), 1600, American Society for Nondestructive Testing (78): : 203 - 212
  • [3] Non-Destructive Imaging Materials Investigation by Microfocus 3D X-Ray Computed Tomography
    Lima, I.
    Assis, J. T.
    Apoloni, C. R.
    Mendonca de Souza, S. M. F.
    Duarte, M. E. L.
    Lopes, R. T.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1448 - 1453
  • [4] 3D quantification of mineral components and porosity distribution in Westphalian C sandstone by microfocus X-ray computed tomography
    Long, Haili
    Swennen, Rudy
    Foubert, Anneleen
    Dierick, Manuel
    Jacobs, Patric
    SEDIMENTARY GEOLOGY, 2009, 220 (1-2) : 116 - 125
  • [5] X-ray microfocus computed tomography: a powerful tool for structural and functional characterisation of 3D printed dosage forms
    Gioumouxouzis, C. I.
    Katsamenis, O. L.
    Fatouros, D. G.
    JOURNAL OF MICROSCOPY, 2020, 277 (03) : 135 - 139
  • [6] Automated seed testing by 3D X-ray computed tomography
    Porsch, Felix
    SEED SCIENCE AND TECHNOLOGY, 2020, 48 (01) : 73 - 81
  • [7] Characterization of hollow fiber supported Ionic liquid membranes using microfocus X-ray computed tomography
    Dai, Sheng
    Seol, Yongkoo
    Wickramanayake, Shan
    Hopkinson, David
    JOURNAL OF MEMBRANE SCIENCE, 2015, 492 : 497 - 504
  • [8] Characterisation of fibre suspensions using X-ray computed tomography and image analysis
    Ringnér, J
    Rasmuson, A
    NORDIC PULP & PAPER RESEARCH JOURNAL, 2000, 15 (04) : 319 - 325
  • [9] Imaging and Analysis Techniques for Electrical Trees using X-ray Computed Tomography
    Schurch, Roger
    Rowland, Simon M.
    Bradley, Robert S.
    Withers, Philip J.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (01) : 53 - 63
  • [10] Comparison of 3D X-ray tomography with computed tomography in patients with distal extremity fractures
    Falkowski, Anna L.
    Kovacs, Balazs K.
    Schwartz, Fides R.
    Benz, Robyn M.
    Stieltjes, Bram
    Hirschmann, Anna
    SKELETAL RADIOLOGY, 2020, 49 (12) : 1965 - 1975