Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography

被引:158
作者
Sukovic, P [1 ]
Clinthorne, NH
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Internal Med, Div Nucl Med, Ann Arbor, MI 48109 USA
关键词
dual energy X-ray transmission tomography; statistical image reconstruction;
D O I
10.1109/42.896783
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a dual-energy (DE) transmission computed tomography (CT) reconstruction method. It is statistically motivated and features nonnegativity constraints in the density domain. A penalized weighted least squares (PWLS) objective function has been chosen to handle the non-Poisson noise added by amorphous silicon (aSi:H) detectors. A Gauss-Seidel algorithm has been used to minimize the objective function. The behavior of the method in terms of bias/standard deviation tradeoff has been compared to that of a DE method that is based on filtered back projection (FBP). The advantages of the DE PWLS method are largest for high noise and/or low flux cases, Qualitative results suggest this as well. Also, the reconstructed images of an object with opaque regions are presented. Possible applications of the method are: attenuation correction for positron emission tomography (PET) images, various quantitative computed tomography (QCT) methods such as bone mineral densitometry (BMD), and the removal of metal streak artifacts.
引用
收藏
页码:1075 / 1081
页数:7
相关论文
共 23 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
MCSHAN, DL ;
MORTON, EJ ;
YORKSTON, J ;
LONGO, MJ ;
STREET, RA .
MEDICAL PHYSICS, 1992, 19 (06) :1455-1466
[3]   ARE HYDROGENATED AMORPHOUS-SILICON ARRAYS USABLE FOR TOMOGRAPHIC IMAGING [J].
CLINTHORNE, NH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1516-1521
[4]   A CONSTRAINED DUAL-ENERGY RECONSTRUCTION METHOD FOR MATERIAL-SELECTIVE TRANSMISSION TOMOGRAPHY [J].
CLINTHORNE, NH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :347-348
[5]  
ENGLER P, 1990, MATER EVAL, V48, P623
[6]   PENALIZED WEIGHTED LEAST-SQUARES IMAGE-RECONSTRUCTION FOR POSITRON EMISSION TOMOGRAPHY [J].
FESSLER, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :290-300
[7]  
FESSLER JA, 1995, 293 U MICH
[8]   Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise [J].
Hsieh, J .
MEDICAL PHYSICS, 1998, 25 (11) :2139-2147
[9]  
KALENDER AW, 1988, IEEE T MED IMAGING, V7, P218
[10]   PROTOTYPE OF DUAL ENERGY X-RAY TOMODENSIMETER FOR LUMBAR SPINE BONE-MINERAL DENSITY-MEASUREMENT - CHOICE OF THE RECONSTRUCTION ALGORITHM AND 1ST EXPERIMENTAL RESULTS [J].
KOTZKI, PO ;
MARIANOGOULART, D ;
ROSSI, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (12) :2253-2265