A Comparative Biomechanical Analysis of Stand Alone Versus Facet Screw and Pedicle Screw Augmented Lateral Interbody Arthrodesis: An In Vitro Human Cadaveric Model

被引:17
|
作者
Kretzer, Ryan M. [1 ,2 ]
Molina, Camilo [3 ]
Hu, Nianbin [2 ]
Umekoji, Hidemasa [2 ]
Baaj, Ali A. [4 ]
Serhan, Hassan [5 ]
Cunningham, Bryan W. [2 ]
机构
[1] St Josephs Hosp, Western Neurosurg Ltd, 6567 E Carondelet Dr,Suite 305, Tucson, AZ 85710 USA
[2] St Joseph Med Ctr, Orthopaed Spinal Res Lab, Towson, MD USA
[3] Johns Hopkins Univ, Sch Med, Dept Neurosurg, Baltimore, MD 21205 USA
[4] Univ Arizona, Med Ctr, Div Neurosurg, Tucson, AZ USA
[5] DePuy Spine, Raynham, MA USA
来源
CLINICAL SPINE SURGERY | 2016年 / 29卷 / 07期
关键词
facet screws; pedicle screws; lateral interbody fusion; TRANSLAMINAR FACET; LUMBAR FUSION; COMPLICATIONS; FIXATION; OUTCOMES; SCOLIOSIS; SURGERY; SPINE;
D O I
10.1097/BSD.0b013e3182868ef9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design:Cadaveric biomechanical study.Objective:To investigate the kinematic response of a stand-alone lateral lumbar interbody cage compared with supplemental posterior fixation with either facet or pedicle screws after lateral discectomy.Summary of Background Data:Lateral interbody fusion is a promising minimally invasive fixation technique for lumbar interbody arthrodesis. The biomechanical stability of stand-alone cage placement compared with supplemental posterior fixation with either facet or bilateral pedicle screws remains unclear.Methods:A 6-degree of freedom spine simulator was used to test flexibility in 7 human cadaveric specimens. Flexion-extension, lateral-bending, and axial-rotation were tested in the intact condition, followed by destabilization through a lateral discectomy at L2-L3 and L4-L5. Specimens were then reconstructed at both operative segments in the following sequence: (1) lateral interbody cage placement; (2) either Discovery facet screws or the Viper F2 system using a transfacet-pedicular trajectory randomized to L2-L3 or L4-L5; and (3) removal of facet screw fixation followed by placement of bilateral pedicle screw instrumentation. Acute range of motion (ROM) was quantified and analyzed.Results:All 4 reconstruction groups, including stand-alone interbody cage placement, bilateral Discovery facet screws, the Viper F2 system, and bilateral pedicle screw-rod stabilization, resulted in a significant decrease in acute ROM in all loading modes tested (P<0.05). There were no significant differences observed between the 4 instrumentation groups (P>0.05). Although not statistically significant, the Viper F2 system resulted in greatest reduction of acute ROM in both flexion-extension and axial rotation versus all other treatments (P>0.05).Conclusions:Stand-alone interbody cage placement results in a significant reduction in acute ROM at the operative segment in the absence of posterior supplemental fixation. If added fixation is desired, facet screw placement, including the Viper F2 facet screw system using an integrated compression washer and transfacet-pedicular trajectory, provides similar acute stability to the spinal segment compared with traditional bilateral pedicle screw fixation in the setting of lateral interbody cage deployment.
引用
收藏
页码:E336 / E343
页数:8
相关论文
共 22 条
  • [1] Biomechanical properties of posterior transpedicular-transdiscal oblique lumbar screw fixation with novel trapezoidal lateral interbody spacer: an in vitro human cadaveric model
    Wu, Ai-Min
    Harris, Jonathan A.
    Hao, John C.
    Jenkins, Sean M.
    Chi, Yong-Long
    Bucklen, Brandon S.
    EUROPEAN SPINE JOURNAL, 2017, 26 (11) : 2873 - 2882
  • [2] Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysis
    Choi, Kyung-Chul
    Ryu, Kyeong-Sik
    Lee, Sang-Ho
    Kim, Yeong Hyeon
    Lee, Sung Jae
    Park, Chun-Kun
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [3] Biomechanical Comparison of Stand-Alone and Bilateral Pedicle Screw Fixation for Oblique Lumbar Interbody Fusion Surgery-A Finite Element Analysis
    Fang, Guofang
    Lin, Yunzhi
    Wu, Jiachang
    Cui, Wengang
    Zhang, Shihao
    Guo, Lili
    Sang, Hongxun
    Huang, Wenghua
    WORLD NEUROSURGERY, 2020, 141 : E204 - E212
  • [4] Biomechanical comparison of different techniques in primary spinal surgery in osteoporotic cadaveric lumbar vertebrae: expansive pedicle screw versus polymethylmethacrylate-augmented pedicle screw
    Liu, Da
    Wu, Zi-xiang
    Pan, Xian-ming
    Fu, Suo-chao
    Gao, Ming-xuan
    Shi, Lei
    Lei, Wei
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1227 - 1232
  • [5] Biomechanical properties of posterior transpedicular–transdiscal oblique lumbar screw fixation with novel trapezoidal lateral interbody spacer: an in vitro human cadaveric model
    Ai-Min Wu
    Jonathan A. Harris
    John C. Hao
    Sean M. Jenkins
    Yong-Long Chi
    Brandon S. Bucklen
    European Spine Journal, 2017, 26 : 2873 - 2882
  • [6] Biomechanical Comparison of Multilevel Stand-Alone Lumbar Lateral Interbody Fusion With Posterior Pedicle Screws: An In Vitro Study
    Mok, James M.
    Lin, Ye
    Tafur, Julio Castillo
    Diaz, Roberto Leonardo
    Amirouche, Farid
    NEUROSPINE, 2023, 20 (02) : 478 - 486
  • [7] Biomechanical Stability Afforded by Unilateral Versus Bilateral Pedicle Screw Fixation with and without Interbody Support Using Lateral Lumbar Interbody Fusion
    Godzik, Jakub
    Martinez-del-Campo, Eduardo
    Newcomb, Anna G. U. S.
    Reis, Marco T.
    Perez-Orribo, Luis
    Whiting, Alexander C.
    Singh, Vaneet
    Kelly, Brian P.
    Crawford, Neil R.
    WORLD NEUROSURGERY, 2018, 113 : E439 - E445
  • [8] Oblique lateral interbody fusion stand-alone vs. combined with percutaneous pedicle screw fixation in the treatment of discogenic low back pain
    Wang, Weiheng
    Xiao, Bing
    Wang, Haotian
    Qi, Junqiang
    Gu, Xin
    Yu, Jiangming
    Ye, Xiaojian
    Xu, Guohua
    Xi, Yanhai
    FRONTIERS IN SURGERY, 2022, 9
  • [9] Biomechanical comparison between cortical screw-rod construct versus pedicle screw-rod construct in transforaminal lumbar interbody fusion: A porcine animal study model
    Wei, Chris Chan Yin
    Haw, Sem Sei
    Bashir, Elrofai Suliman
    Beng, Saw Lim
    Shanmugam, Rukmanikanthan
    Keong, Kwan Mun
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01):
  • [10] Biomechanical assessment of anterior lumbar interbody fusion with an anterior lumbosacral fixation screw-plate: Comparison to stand-alone anterior lumbar interbody fusion and anterior lumbar interbody fusion with pedicle screws in an unstable human cadaver model
    Gerber, M
    Crawford, NR
    Chamberlain, RH
    Fifield, MS
    LeHuec, JC
    Dickman, CA
    SPINE, 2006, 31 (07) : 762 - 768