Detection of metallic cobalt and chromium liver deposition following failed hip replacement using T2*and R2 magnetic resonance

被引:23
作者
Abdel-Gadir, Amna [1 ,2 ]
Berber, Reshid [3 ]
Porter, John B. [4 ]
Quinn, Paul D. [5 ]
Suri, Deepak [6 ]
Kellman, Peter [7 ]
Hart, Alister J. [3 ]
Moon, James C. [1 ,2 ]
Manisty, Charlotte [1 ,2 ]
Skinner, John A. [3 ]
机构
[1] UCL, Inst Cardiovasc Sci, London, England
[2] St Bartholomews Hosp, Barts Heart Ctr, London, England
[3] Royal Natl Orthoped Hosp, Stanmore, Middx, England
[4] UCL, Dept Hematol, London, England
[5] Diamond Light Source, Harwell Sci & Innovat Campus, Harwell, Berks, England
[6] Whittington Hosp, Dept Gastroenterol, London N19 5NF, England
[7] NHLBI, Med Signal & Image Proc Program, Bldg 10, Bethesda, MD 20892 USA
关键词
MRI; T2*; Metal-on-metal hip; Cobalt; Chromium; Metal loading; IRON OVERLOAD; RESURFACING ARTHROPLASTY; DIAGNOSIS;
D O I
10.1186/s12968-016-0248-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Failed hip prostheses can cause elevated circulating cobalt and chromium levels, with rare reports of fatal systemic organ deposition, including cobalt cardiomyopathy. Although blood cobalt and chromium levels are easily measured, organ deposition is difficult to detect without invasive biopsy. The T2* magnetic resonance (MR) method is used to quantify tissue iron deposition, and plays an important role in the management of iron-loading conditions. Cobalt and chromium, like iron, also affect magnetism and are proposed MR contrast agents. Case Presentation: We describe a case of a 44-year-old male with a failed hip implant and very elevated blood cobalt and chromium levels. Despite normal cardiac MR findings, liver T2* and R2 values were abnormal, triggering tissue biopsy. Liver tissue analysis, including X-ray fluorescence, demonstrated heavy elemental cobalt and chromium deposition in macrophages, and no detectable iron. Conclusions: Our case demonstrates T2* and R2 quantification of liver metal deposition in a patient with a failed hip implant. Further work is needed to investigate the role of T2* and R2 MR in the detection of metal deposition from metal on metal hip prostheses.
引用
收藏
页数:5
相关论文
共 19 条
[1]   Assessment of Iron Overload with T2*Magnetic Resonance Imaging [J].
Anderson, Lisa J. .
PROGRESS IN CARDIOVASCULAR DISEASES, 2011, 54 (03) :287-294
[2]   Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload [J].
Anderson, LJ ;
Holden, S ;
Davis, B ;
Prescott, E ;
Charrier, CC ;
Bunce, NH ;
Firmin, DN ;
Wonke, B ;
Porter, J ;
Walker, JM ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2001, 22 (23) :2171-2179
[3]   Systemic toxicity related to metal hip prostheses [J].
Bradberry, S. M. ;
Wilkinson, J. M. ;
Ferner, R. E. .
CLINICAL TOXICOLOGY, 2014, 52 (08) :837-847
[4]   On T2*Magnetic Resonance and Cardiac Iron [J].
Carpenter, John-Paul ;
He, Taigang ;
Kirk, Paul ;
Roughton, Michael ;
Anderson, Lisa J. ;
de Noronha, Sofia V. ;
Sheppard, Mary N. ;
Porter, John B. ;
Walker, J. Malcolm ;
Wood, John C. ;
Galanello, Renzo ;
Forni, Gianluca ;
Catani, Gualtiero ;
Matta, Gildo ;
Fucharoen, Suthat ;
Fleming, Adam ;
House, Michael J. ;
Black, Greg ;
Firmin, David N. ;
St Pierre, Timothy G. ;
Pennell, Dudley J. .
CIRCULATION, 2011, 123 (14) :1519-1528
[5]  
de Valk B, 2000, Eur J Intern Med, V11, P317, DOI 10.1016/S0953-6205(00)00111-4
[6]   HFE C282Y/H63D Compound Heterozygotes Are at Low Risk of Hemochromatosis-Related Morbidity [J].
Gurrin, Lyle C. ;
Bertalli, Nadine A. ;
Dalton, Gregory W. ;
Osborne, Nicholas J. ;
Constantine, Clare C. ;
McLaren, Christine E. ;
English, Dallas R. ;
Gertig, Dorota M. ;
Delatycki, Martin B. ;
Nicoll, Amanda J. ;
Southey, Melissa C. ;
Hopper, John L. ;
Giles, Graham G. ;
Anderson, Gregory J. ;
Olunyk, John K. ;
Powell, Lawrie W. ;
Allen, Katrina J. .
HEPATOLOGY, 2009, 50 (01) :94-101
[7]   Insufficient Acetabular Version Increases Blood Metal Ion Levels after Metal-on-metal Hip Resurfacing [J].
Hart, Alister J. ;
Skinner, John A. ;
Henckel, Johann ;
Sampson, Barry ;
Gordon, Fabiana .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (09) :2590-2597
[8]   Do Complication Rates Differ by Gender After Metal-on-metal Hip Resurfacing Arthroplasty? A Systematic Review [J].
Haughom, Bryan D. ;
Erickson, Brandon J. ;
Hellman, Michael D. ;
Jacobs, Joshua J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (08) :2521-2529
[9]   Normal values for cardiovascular magnetic resonance in adults and children [J].
Kawel-Boehm, Nadine ;
Maceira, Alicia ;
Valsangiacomo-Buechel, Emanuela R. ;
Vogel-Claussen, Jens ;
Turkbey, Evrim B. ;
Williams, Rupert ;
Plein, Sven ;
Tee, Michael ;
Eng, John ;
Bluemke, David A. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[10]   Unusual Case of Congestive Heart Failure Cardiac Magnetic Resonance Imaging and Histopathologic Findings in Cobalt Cardiomyopathy [J].
Khan, Akbar H. ;
Verma, Rajanshu ;
Bajpai, Ambareesh ;
Mackey-Bojack, Shannon .
CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (06)