A Systematic Review on Immediate Loading of Implants Used to Support Overdentures Opposed by Conventional Prostheses: Factors That Might Influence Clinical Outcomes

被引:16
作者
Zygogiannis, Kostas [1 ]
Wismeijer, Daniel [1 ]
Aartman, Irene H. A. [2 ]
Osman, Reham B. [3 ,4 ]
机构
[1] ACTA Gustav Mahlerlaan, Dept Oral Funct & Restorat Dent, Sect Oral Implantol & Prosthodont, Amsterdam, Netherlands
[2] ACTA Gustav Mahlerlaan, Dept Social Dent & Behav Sci, Amsterdam, Netherlands
[3] Acad Centrum Dent Amsterdam ACTA, Dept Oral Implantol & Prosthet Dent, Amsterdam, Netherlands
[4] Cairo Univ, Dept Removable Prosthodont, Giza, Egypt
关键词
dental implants; implant supported/retained overdentures; immediate loading; mandible; systematic review; RETAINED MANDIBULAR OVERDENTURES; MARGINAL BONE LOSS; MINI-IMPLANTS; PROTOCOLS; MULTICENTER;
D O I
10.11607/jomi.4028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Different treatment protocols in terms of number, diameter, and suprastructure design have been proposed for immediately loaded implants that are used to support mandibular overdentures opposed by maxillary conventional dentures. The aim of this study was to investigate the influence of these protocols on survival rates as well as clinical and prosthodontic outcomes. Materials and Methods: Several electronic databases were searched for all relevant articles published from 1966 to June 2014. Only randomized controlled trials and prospective studies with a minimum follow-up of 12 months were selected. The primary outcomes of interest were the success and survival rates of the implants. Prosthodontic complications were also evaluated. Results: Fourteen studies fulfilled the inclusion criteria. Of the studies identified, nine were randomized controlled trials and five were prospective studies. The mean follow-up period was 3 years or less for the vast majority of the studies. The reported survival and success rates were comparable to that of conventional loading for most of the included studies. No specific immediate loading protocol seemed to perform better in terms of clinical and prosthodontic outcomes. Conclusion: Immediate loading protocols of mandibular overdentures seem to be a viable alternative to conventional loading. It was not possible to recommend a specific treatment protocol related to the number, diameter of the implants, and attachment system used. Long-term, well-designed studies comparing different immediate loading modalities could help to establish a protocol that delivers the most clinically predictable, efficient, and cost-effective outcome for edentulous patients in need of implant overdentures.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 48 条
[1]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]   Clinical and Radiographic Evaluation of Implant-Retained Mandibular Overdentures With Immediate Loading [J].
Assad, Ahmed S. ;
Hassan, Susan A. ;
Shawky, Yasser M. ;
Badawy, Magdy M. .
IMPLANT DENTISTRY, 2007, 16 (02) :212-223
[4]  
Attard NJ, 2005, INT J PROSTHODONT, V18, P463
[5]   MINI IMPLANTS FOR DEFINITIVE PROSTHODONTIC TREATMENT: A SYSTEMATIC REVIEW [J].
Bidra, Avinash S. ;
Almas, Khalid .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (03) :156-164
[6]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[7]  
Bulard Ronald A, 2005, Compend Contin Educ Dent, V26, P892
[8]  
Buttel Adrian E, 2012, Schweiz Monatsschr Zahnmed, V122, P392
[9]   Immediate loading of dental implants in the edentulous mandible [J].
Castellon, P ;
Blatz, MB ;
Block, MS ;
Finger, IM ;
Rogers, B .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (11) :1543-1549
[10]  
Chiapasco M, 2004, INT J ORAL MAX IMPL, V19, P76