Evaluation of diagnostic methods for the detection of Bovine Coronavirus and Rotavirus in faeces of diarrhoeic calves

被引:1
|
作者
Hamedian-Asl, Mohammad [1 ]
Zakian, Amir [2 ]
Azimpour, Saeid [3 ]
Davoodi, Farshid [4 ]
Kahroba, Human [5 ,6 ,7 ]
机构
[1] Islamic Azad Univ, Babol Branch, Sch Vet Med, Babol, Mazandaran, Iran
[2] Lorestan Univ, Fac Vet Med, Dept Clin Sci, Khorramabad, Iran
[3] Islamic Azad Univ, Babol Branch, Fac Vet Med, Dept Clin Sci, Babol, Mazandaran, Iran
[4] Urmia Univ, Fac Vet Med, Dept Surg & Diagnost Imaging, Orumiyeh, Iran
[5] Tabriz Univ, Fac Adv Med Sci, Dept Mol Med, Tabriz, Iran
[6] Maastricht Univ, GROW Sch Oncol & Dev Biol, Dept Toxicogenom, Maastricht, Netherlands
[7] Hasselt Univ, Ctr Environm Sci, Hasselt, Belgium
来源
JOURNAL OF THE HELLENIC VETERINARY MEDICAL SOCIETY | 2022年 / 73卷 / 02期
关键词
calf diarrhoea; rotavirus; bovine coronavirus; immunochromatography; RT-PCR; ENTERIC PATHOGENS; 4; ENTEROPATHOGENS; CALF DIARRHEA; RAPID TEST; PREVALENCE; ELISA; TIME; ETIOLOGY; ANTIGEN; AGENTS;
D O I
10.12681/jhvms.23704
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The purpose of the present study was to evaluate the efficacy of Enzyme-Linked Immunosorbent Assay (ELISA), immunochromatographic (ICG), and reverse transcription-polymerase chain reaction (RT-PCR) methods for the detection of rotavirus (RV) and bovine coronavirus (BCV). Faeces samples were collected from 90 diarrhoeic calves (male and female) up to one month of age and the immune response against RV and BCV infection was as-sessed by using AgELISA, ICG, and RT-PCR. To determine the performance and accuracy of each diagnostic method in comparison to the diagnostic gold standard (RT-PCR) method, different statistical tests including receiver operating characteristic curve (ROC) and concordance correlation were used. Results revealed the prevalence of RV and BCV and RV+BCV according to RT-PCR were equal to 8.89 (95% CI: 6.64-10.07), 14.44 (95% CI: 11.23-6.90), and 2.22 (95% CI: 0.89-3.72), respectively. The best agreement and the highest sensitivity and specificity were obtained be-tween the RT-PCR and AgELISA (100% and 94.3%), and also the ICG test (95% and 94.3%) was less accurate method in comparison to ELISA method for identifying RV and BCV, but a good correlation and concordance between ICG diagnostic techniques and RT-PCR were observed. To put it in a nutshell, our results demonstrate that the AgELISA is the most accurate technique in comparison to RT-PCR, however the ICG assay can help improve the speed of diagnosis RV and BCV infections in dairy field. New scientific strategies for promoting accuracy and transparency of ICG-based technique in early diagnosis of the cause of calf diarrhoea should be used. Altogether, we suggest that positive ICG samples should be tested by AgELISA or RT-PCR techniques to avoid false results in farm animals.
引用
收藏
页码:3951 / 3960
页数:11
相关论文
共 50 条
  • [41] Evaluation of the utility value of three diagnostic methods in the detection of malaria parasites in endemic area
    Ugah, Uchenna Iyioku
    Alo, Moses Nnaemeka
    Owolabi, Jacob Oluwabusuyi
    Okata-Nwali, Oluchi DivineGift
    Ekejindu, Ifeoma Mercy
    Ibeh, Nancy
    Elom, Michael Okpara
    MALARIA JOURNAL, 2017, 16
  • [42] Performance Evaluation of Diagnostic Methods for Schistosoma mansoni Detection in Amhara Region, Northwest Ethiopia
    Fenta, Abebe
    Hailu, Tadesse
    Alemu, Megbaru
    Amor, Arancha
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [43] Detection of rotavirus A in sewage samples using multiplex qPCR and an evaluation of the ultracentrifugation and adsorption-elution methods for virus concentration
    Fumian, Tulio M.
    Leite, Jose Paulo G.
    Castello, Alejandro A.
    Gaggero, Aldo
    de Caillou, Maria Susana L.
    Miagostovich, Marize P.
    JOURNAL OF VIROLOGICAL METHODS, 2010, 170 (1-2) : 42 - 46
  • [44] Evaluation of glutamic acid decarboxylase (GAD) 65 antibody detection methods for neurological and diabetic investigation in an Australian diagnostic laboratory
    Cecchin, Amelia
    Reynolds, Claire
    Ali, Syed
    Hissaria, Pravin
    PATHOLOGY, 2023, 55 (04) : 538 - 542
  • [45] Comparative evaluation of immunochromatographic rapid diagnostic tests (strip and device) and PCR methods for detection of human hepatitis B surface antigens
    Ansari, Mohammad Hassan Khadem
    Omrani, Mir Davood
    Movahedi, Vahid
    HEPATITIS MONTHLY, 2007, 7 (02) : 87 - 91
  • [46] Diagnostic accuracy of Elisa methods as an alternative screening test to indirect immunofluorescence for the detection of antinuclear antibodies. Evaluation of five commercial kits
    Tonutti, E
    Bassetti, D
    Piazza, A
    Visentini, D
    Poletto, M
    Bassetto, F
    Caciagli, P
    Villalta, D
    Tozzoli, R
    Bizzaro, N
    AUTOIMMUNITY, 2004, 37 (02) : 171 - 176
  • [47] Development and evaluation of a Luminex multiplex serology assay to detect antibodies to bovine herpes virus 1, parainfluenza 3 virus, bovine viral diarrhoea virus, and bovine respiratory syncytial virus, with comparison to existing ELISA detection methods
    Anderson, Steve
    Wakeley, Phil
    Wibberley, Guy
    Webster, Kath
    Sawyer, Jason
    JOURNAL OF IMMUNOLOGICAL METHODS, 2011, 366 (1-2) : 79 - 88
  • [48] Evaluation of the performance of Abbott Panbio™ COVID-19 antigen rapid diagnostic test for the detection of severe acute respiratory syndrome coronavirus 2 at Harar, Eastern Ethiopia
    Teklemariam, Zelalem
    Feleke, Dereje
    Abdurahman, Abdusemed
    Alemayehu, Astawus
    Demissie, Abebaw
    Tufa, Asefa
    Sherefa, Nebiyu
    Mohammed, Abdusemed
    Brhane, Mussie
    Bogale, Kasahun
    FRONTIERS IN MEDICINE, 2023, 10
  • [49] Evaluation of diagnostic methods for the detection of intestinal schistosomiasis in endemic areas with low parasite loads: Saline gradient, Helmintex, Kato-Katz and rapid urine test
    Oliveira, Warllem Junio
    Magalhaes, Fernanda do Carmo
    Saldanha Elias, Andressa Mariana
    de Castro, Vanessa Normandio
    Favero, Vivian
    Lindholz, Catieli Gobetti
    Oliveira, Aureo Almeida
    Barbosa, Fernando Sergio
    Gil, Frederico
    Gomes, Maria Aparecida
    Graeff-Teixeira, Carlos
    Enk, Martin Johannes
    Zech Coelho, Paulo Marcos
    Carneiro, Mariangela
    Negrao-Correa, Deborah Aparecida
    Geiger, Stefan Michael
    PLOS NEGLECTED TROPICAL DISEASES, 2018, 12 (02):
  • [50] Development and evaluation of one-step rRT-PCR and immunohistochemical methods for detection of Rift Valley fever virus in biosafety level 2 diagnostic laboratories
    Drolet, Barbara S.
    Weingartl, Hana M.
    Jiang, Jieyuan
    Neufeld, James
    Marszal, Peter
    Lindsay, Robbin
    Miller, Myrna M.
    Czub, Markus
    Wilson, William C.
    JOURNAL OF VIROLOGICAL METHODS, 2012, 179 (02) : 373 - 382