Haemocompatibility of polymer-coated stainless steel stents as compared to uncoated stents

被引:3
|
作者
Mrowietz, C
Franke, RP
Seyfert, UT
Park, JW
Jung, F
机构
[1] Inst Heart & Circulat Res, D-02977 Hoyerswerda, Germany
[2] Univ Ulm, Dept Biomat, D-89069 Ulm, Germany
[3] Saarlands Univ, Dept Clin Haemostasiol & Transfus Med, Saarbrucken, Germany
[4] Hoyerswerda Hosp, Div Cardiol, Hoyerswerda, Germany
关键词
haemocompatibility; coronary stents; closed-loop; polyphosphazenes;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Acute and subacute stent thrombosis still represent an unsolved problem in connection with endovascular stents. For this reason coatings are tested now with the intention to reduce thrombogenicity of stainless steel surfaces. This comparative study examined whether a polymeric stent coating affected the haemocompatibility of a stainless steel stent. For compatibility testing, coated and non-coated stents were implanted in a low-grade thrombogenic closed-loop system perfused with platelet rich plasma at shear rates far below the threshold value at which shear-rate-induced activation of thrombocytes occurs. After 21 circulations of the filling volume (exposure time: 6.2 min), the number of single circulating platelets in the perfusion system with uncoated stainless steel stents decreased almost twice as much as was the case with polymer-coated stents. This is thought to indicate that more thrombocytes had adhered to the uncoated stainless steel stent, or that the thrombocytes were clustered in circulating aggregates. Parallel to the platelet aggregation/adherence, a release reaction took place, as was evident from the TAT complexes indicating the generation of thrombin. In the case of the implantation of uncoated stainless steel stents, both the number of activated circulating thrombocytes and the level of platelet reactivity (number of thrombocytes circulating in the plasma as aggregates) were notably higher than in the system with polymer-coated stents. At the same time it should be noted that the activation or aggregation is almost wholly attributable to the exogenic surface of the implanted stent, since activation due to the tube system or to shear rate can be excluded (as shown by measurements of the system without a stent). In addition to activation of the thrombocytes, a notable increase in the number of receptors per platelet (significant only in the system with the uncoated stent) took place. This supports both the adherence of the thrombocytes and their readiness to aggregate, since more receptors (docking places for ligands) are available. The better haemocompatibility of the polymer-coated stents, as verified in the laboratory, was also evident under microscopic examination of the explanted stents following the perfusion tests.
引用
收藏
页码:89 / 103
页数:15
相关论文
共 50 条
  • [1] Intense inflammatory reaction to heparin polymer-coated intravascular Palmaz stents in porcine arteries compared to uncoated Palmaz stents
    Goodwin, SC
    Yoon, HC
    Chen, G
    Abdel-Sayed, P
    Costantino, MM
    Bonilla, SM
    Nishimura, E
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 26 (02) : 158 - 167
  • [2] Procedural Performance of Ultrathin, Biodegradable Polymer-Coated Stents Versus Durable Polymer-Coated Stents Based on Intracoronary Imaging
    des Plantes, Annemieke C. Ziedses
    Neleman, Tara
    Forero, Maria N. Tovar
    Visser, Leon
    Scoccia, Alessandra
    Groenland, Frederik T. W.
    Ligthart, Jurgen M. R.
    Boersma, Eric
    Nuis, Rutger-Jan
    den Dekker, Wijnand K.
    Wilschut, Jeroen
    Diletti, Roberto
    Zijlstra, Felix
    Van Mieghem, Nicolas M.
    Daemen, Joost
    JOURNAL OF INVASIVE CARDIOLOGY, 2022, 34 (11): : E811 - E819
  • [3] Paclitaxel polymer-coated stents reduce neointima
    Farb, A
    Heller, PF
    Carter, AJ
    Cheng, L
    Min, DH
    Kolodgie, F
    Froehlich, JP
    Virmani, R
    CIRCULATION, 1997, 96 (08) : 3394 - 3394
  • [4] Intense Inflammatory Reaction to Heparin Polymer Coated Intravascular Palmaz Stents in Porcine Arteries Compared to Uncoated Palmaz Stents
    Scott C. Goodwin
    Hyo-Chun Yoon
    Gary Chen
    Peter Abdel-Sayed
    Mary M. Costantino
    Sheila M. Bonilla
    Earl Nishimura
    CardioVascular and Interventional Radiology, 2003, 26 : 158 - 167
  • [5] Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease
    Airoldi, F
    Colombo, A
    Tavano, D
    Stankovic, G
    Klugmann, S
    Paolillo, V
    Bonizzoni, E
    Briguori, C
    Carlino, M
    Montorfano, M
    Liistro, F
    Castelli, A
    Ferrari, A
    Sgura, F
    Di Mario, C
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04): : 474 - 477
  • [6] BACTERIAL ADHERENCE TO HYDROPHILIC POLYMER-COATED POLYURETHANE STENTS
    JANSEN, B
    GOODMAN, LP
    RUITEN, D
    GASTROINTESTINAL ENDOSCOPY, 1993, 39 (05) : 670 - 673
  • [7] The Surface Modification Methods for Constructing Polymer-Coated Stents
    Fan, Yanqin
    Li, Xiang
    Yang, Ruijie
    INTERNATIONAL JOURNAL OF POLYMER SCIENCE, 2018, 2018
  • [8] Improvement of haemocompatibility of metallic stents by polymer coating
    Lahann, J
    Klee, D
    Thelen, H
    Bienert, H
    Vorwerk, D
    Höcker, H
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (07) : 443 - 448
  • [9] Improvement of haemocompatibility of metallic stents by polymer coating
    J. Lahann
    D. Klee
    H. Thelen
    H. Bienert
    D. Vorwerk
    H. Ho¨cker
    Journal of Materials Science: Materials in Medicine, 1999, 10 : 443 - 448
  • [10] Efficacy of vascular oligonucleotide transfer using polymer-coated stents
    Radke, PW
    Kivela, A
    Vick, T
    Griesenbach, U
    Yla-Hertualla, S
    Alton, EW
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 27E - 28E