Diethylhexyl phthalate (DEHP) emission to indoor air and transfer to house dust from a PVC sheet

被引:28
|
作者
Shinohara, Naohide [1 ]
Uchino, Kanako [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Res Inst Sci Safety & Sustainabil RISS, 16-1 Onogawa, Tsukuba, Ibaraki 3058569, Japan
基金
日本学术振兴会;
关键词
DEHP; Emission; Transfer; Particle; Adsorption; Ingestion; EXPOSURE; ASSOCIATION; ESTERS; CHILDREN; FLUX; SYMPTOMS; TOXICITY; ASTHMA; FLEC;
D O I
10.1016/j.scitotenv.2019.134573
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Diethylhexyl phthalate (DEHP) emission to air and transfer to house dust from a polyvinyl chloride (PVC) sheet were quantified for periods of 1, 3, 7, and 14 days using a passive flux sampler (PFS). Japanese Industrial Standards (JIS) test powders class 15 was used as the test house dust in settled weights of 0.3, 1, 3, and 12 mg/cm(2). DEHP concentrations in the surface air on the PVC sheet were estimated as 2.6-3.3 mu g/m(3) according to an emission test without dust. Although DEHP transfer rates from the PVC sheet to the house dust decreased over time, the adsorption did not reach an equilibrium state within 14 days. The transfer rates per dust weight increased with decreasing dust weight on the PVC sheet. The transfer rates per PVC sheet area increased nonlinearly with increasing dust weight on the PVC sheet. DEHP emission from a PVC sheet to air was one to three orders of magnitude lower than DEHP transfer from a PVC sheet to dust. In the case of 0.3 mg/cm(2) of settled house dust for 7 days, the emission rates to air were 35, 15, 9.1, 6.4, and 3.8 mu g/m(2)/h for a diffusion distance of 0.90, 1.85, 2.75, 3.80, and 5.75 mm, respectively, and the transfer rate to dust was 5.3 x 10(2) mu g/m(2)/h (no difference among the five diffusion distances). Compared to residents who clean the floor every day, exposure to DEHP in house dust could be 10 times higher for residents who clean the floor once every two weeks based on the time-weighted average concentrations in house dust. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Release behavior of diethylhexyl phthalate from the polyvinyl-chloride tubing used for intravenous administration and the plasticized PVC membrane
    Takehisa, H
    Naoko, E
    Masahiko, S
    Katsuhide, T
    Moriyuki, O
    Keizoh, S
    Mutsuko, T
    Kenji, K
    Shin'ichiro, N
    Toshio, O
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2005, 297 (1-2) : 30 - 37
  • [32] Novel classification criterion of indoor organic pollutants based on their relative abundances in house dust and indoor air
    Duan, Xingyu
    Zhu, Yujie
    Cao, Jianping
    BUILDING AND ENVIRONMENT, 2025, 270
  • [33] A novel method for assessing indoor di 2-ethylhexyl phthalate (DEHP) contamination and exposure based on dust-phase concentration
    Zhou X.
    Kang L.
    Wang X.
    Meng H.
    Chemosphere, 2024, 349
  • [34] Di-(2-Ethylhexyl) Phthalate (DEHP) in House Dust in Canadian Homes: Behaviors and Associations with Housing Characteristics and Consumer Products
    Zhang, Luyao
    Navaranjan, Garthika
    Takaro, Tim K.
    Bernstein, Sarah
    Jantunen, Liisa
    Lou, Wendy
    Mandhane, Piush J.
    Moraes, Theo J.
    Scott, James A.
    Simons, Elinor
    Turvey, Stuart E.
    Subbarao, Padmaja
    Brook, Jeffrey R.
    INDOOR AIR, 2023, 2023
  • [35] Investigation on Per- and Polyfluorinated Compounds in Paired Samples of House Dust and Indoor Air from Norwegian Homes
    Haug, Line S.
    Huber, Sandra
    Schabach, Martin
    Becher, Georg
    Thomsen, Cathrine
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (19) : 7991 - 7998
  • [36] Semi volatile organic compounds in indoor air - Scope and limits of the analysis of house dust
    Koerner, W.
    Walker, G.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2013, 73 (03): : 77 - 80
  • [37] Enantiomeric analysis of chiral pesticides in indoor air, perimeter soil and house dust.
    Yingling, AM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U371 - U371
  • [38] Relationships between estimated flame retardant emissions and levels in indoor air and house dust
    Liagkouridis, I.
    Cequier, E.
    Lazarov, B.
    Cousins, A. Palm
    Thomsen, C.
    Stranger, M.
    Cousins, I. T.
    INDOOR AIR, 2017, 27 (03) : 650 - 657
  • [39] PVC dust removal from the air by a new dynamical scrubber
    Zarei, S.
    Jamshidi, E.
    Ebrahimi, A. Afshar
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2010, 49 (11) : 1193 - 1198
  • [40] Phthalate and non- phthalate plasticizers in indoor dust from childcare facilities, salons, and homes across the USA
    Subedi, Bikram
    Sullivan, Kenneth
    Dhungana, Birendra
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254