Diethylhexyl phthalate (DEHP) emission to indoor air and transfer to house dust from a PVC sheet

被引:28
作者
Shinohara, Naohide [1 ]
Uchino, Kanako [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Res Inst Sci Safety & Sustainabil RISS, 16-1 Onogawa, Tsukuba, Ibaraki 3058569, Japan
基金
日本学术振兴会;
关键词
DEHP; Emission; Transfer; Particle; Adsorption; Ingestion; EXPOSURE; ASSOCIATION; ESTERS; CHILDREN; FLUX; SYMPTOMS; TOXICITY; ASTHMA; FLEC;
D O I
10.1016/j.scitotenv.2019.134573
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Diethylhexyl phthalate (DEHP) emission to air and transfer to house dust from a polyvinyl chloride (PVC) sheet were quantified for periods of 1, 3, 7, and 14 days using a passive flux sampler (PFS). Japanese Industrial Standards (JIS) test powders class 15 was used as the test house dust in settled weights of 0.3, 1, 3, and 12 mg/cm(2). DEHP concentrations in the surface air on the PVC sheet were estimated as 2.6-3.3 mu g/m(3) according to an emission test without dust. Although DEHP transfer rates from the PVC sheet to the house dust decreased over time, the adsorption did not reach an equilibrium state within 14 days. The transfer rates per dust weight increased with decreasing dust weight on the PVC sheet. The transfer rates per PVC sheet area increased nonlinearly with increasing dust weight on the PVC sheet. DEHP emission from a PVC sheet to air was one to three orders of magnitude lower than DEHP transfer from a PVC sheet to dust. In the case of 0.3 mg/cm(2) of settled house dust for 7 days, the emission rates to air were 35, 15, 9.1, 6.4, and 3.8 mu g/m(2)/h for a diffusion distance of 0.90, 1.85, 2.75, 3.80, and 5.75 mm, respectively, and the transfer rate to dust was 5.3 x 10(2) mu g/m(2)/h (no difference among the five diffusion distances). Compared to residents who clean the floor every day, exposure to DEHP in house dust could be 10 times higher for residents who clean the floor once every two weeks based on the time-weighted average concentrations in house dust. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 39 条
  • [1] Emission of phthalates from PVC and other materials
    Afshari, A
    Gunnarsen, L
    Clausen, PA
    Hansen, V
    [J]. INDOOR AIR, 2004, 14 (02) : 120 - 128
  • [2] AIST: National Institute of Advanced Industrial Science and Technology, 2016, 2016 EXPL MAT PROD D
  • [3] Exposure to phthalates in house dust and associated allergies in children aged 6-12 years
    Bamai, Yu Ait
    Araki, Atsuko
    Kawai, Toshio
    Tsuboi, Tazuru
    Saito, Ikue
    Yoshioka, Eiji
    Cong, Shi
    Kishi, Reiko
    [J]. ENVIRONMENT INTERNATIONAL, 2016, 96 : 16 - 23
  • [4] DEHP metabolites in urine of children and DEHP in house dust
    Becker, K
    Seiwert, M
    Angerer, J
    Heger, W
    Koch, HM
    Nagorka, R
    Rosskamp, E
    Schlüter, C
    Seifert, B
    Ullrich, D
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2004, 207 (05) : 409 - 417
  • [5] Children's Phthalate Intakes and Resultant Cumulative Exposures Estimated from Urine Compared with Estimates from Dust Ingestion, Inhalation and Dermal Absorption in Their Homes and Daycare Centers
    Beko, Gabriel
    Weschler, Charles J.
    Langer, Sarka
    Callesen, Michael
    Toftum, Jorn
    Clausen, Geo
    [J]. PLOS ONE, 2013, 8 (04):
  • [6] Organophosphate and phthalate esters in air and settled dust - a multi-location indoor study
    Bergh, C.
    Torgrip, R.
    Emenius, G.
    Ostman, C.
    [J]. INDOOR AIR, 2011, 21 (01) : 67 - 76
  • [7] Phthalate exposure and asthma in children
    Bornehag, C. G.
    Nanberg, E.
    [J]. INTERNATIONAL JOURNAL OF ANDROLOGY, 2010, 33 (02): : 333 - 345
  • [8] Phthalates in indoor dust and their association with building characteristics
    Bornehag, CG
    Lundgren, B
    Weschler, CJ
    Sigsgaard, T
    Hagerhed-Engman, L
    Sundell, J
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (10) : 1399 - 1404
  • [9] The association between asthma and allergic symptoms in children and phthalates in house dust:: A nested case-control study
    Bornehag, CG
    Sundell, J
    Weschler, CJ
    Sigsgaard, T
    Lundgren, B
    Hasselgren, M
    Hägerhed-Engman, L
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2004, 112 (14) : 1393 - 1397
  • [10] Emission of Di-2-ethylhexyl phthalate from PVC flooring into air and uptake in dust: Emission and sorption experiments in FLEC and CLIMPAQ
    Clausen, PA
    Hansen, V
    Gunnarsen, L
    Afshari, A
    Wolkoff, P
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (09) : 2531 - 2537