Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry

被引:69
|
作者
Turpeinen, Ursula [1 ]
Hamalainen, Esa [1 ,2 ]
Stenman, Ulf-Hakan [2 ]
机构
[1] HUSLAB, Lab Womens Clin, Helsinki 00029, Finland
[2] Univ Helsinki, Dept Clin Chem, SF-00100 Helsinki, Finland
关键词
serum aldosterone; LC-MS/MS; ESI; Electrospray ionization mass spectrometry; API; 3000; RIA;
D O I
10.1016/j.jchromb.2007.11.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of serum aldosterone is clinically important in the diagnosis of hypertension.)While isotope dilution gas chromatography-mass spectrometry (ID-GC-MS) provides reliable results, it requires derivatization and is lengthy and time-consuming. Detection by liquid chromatography-mass spectrometry (LC-MS) is a potentially superior method. The analysis utilizes 0.5 mL of serum. The samples were extracted with dichloromethane-ether. The extract was evaporated to dryness and aldosterone was analyzed by LC-MS/MS operating in the negative mode ESI after separation on a reversed-phase column. Aldosterone was also measured by RIA. The calibration curves for analysis of serum aldosterone exhibited consistent linearity and reproducibility in the range of 60-3000 pmol/L. Interassay CVs were 4.3-7.5% at aldosterone concentrations of 97-993 pmol/L. The lower limit of quantitation (LOQ) was 30 pmol/L (signal to noise ratio = 10). The mean recovery of the analyte added to serum ranged from 95 to 102%. The regression equation by LC-MS/MS (x) and RIA (y) method was: y = 1.33x + 185 (r = 0.95; n = 124). Sensitivity and specificity of the LC-MS/MS method for serum aldosterone offer advantages over GC-MS by eliminating derivatization. The novel method is rapid, reliable and simple to perform with a routine LC-MS/MS spectrometer. The sensitivity is adequate for patient samples. Aldosterone concentrations reported by nonextraction RIA were consistently higher than those produced by LC-MS/MS. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [31] Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry
    Wang, Dongli
    Stapleton, Heather M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1831 - 1839
  • [32] Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry
    Dongli Wang
    Heather M. Stapleton
    Analytical and Bioanalytical Chemistry, 2010, 397 : 1831 - 1839
  • [33] Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry
    Upreti, Rita
    Homer, Natalie Z. M.
    Naredo, Gregorio
    Cobice, Diego F.
    Hughes, Katherine A.
    Stewart, Laurence H.
    Walker, Brian R.
    Andrew, Ruth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 930 : 121 - 128
  • [34] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the determination of leuprolide in human serum
    Zhan, Yan
    Chen, Xiaoyan
    Zhao, Xiaohua
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27): : 3194 - 3200
  • [35] Quantitative determination of tilmicosin in canine serum by high performance liquid chromatography-tandem mass spectrometry
    Herrera, Michael
    Ding, Haiqing
    McClanahan, Robert
    Owens, Jane G.
    Hunter, Robert P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (01): : 9 - 14
  • [36] High Performance Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Bile Acids in Mouse Serum
    Gao, T.
    Sun, C.
    Tang, H.
    Bi, Y.
    Song, Y.
    Zhang, J.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 79 (02) : 307 - U189
  • [37] Simultaneous determination of eight β-lactam antibiotics in human serum by liquid chromatography-tandem mass spectrometry
    Ohmori, Tomofumi
    Suzuki, Akio
    Niwa, Takashi
    Ushikoshi, Hiroaki
    Shirai, Kunihiro
    Yoshida, Shozo
    Ogura, Shinji
    Itoh, Yoshinori
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (15-16): : 1038 - 1042
  • [38] Simultaneous determination of linezolid and voriconazole serum concentrations using liquid chromatography-tandem mass spectrometry
    Lu, Qiuya
    He, Xiaoshuang
    Fang, Jie
    Shi, Kaifeng
    Hu, Fengmei
    Bian, Xiaolan
    Wang, Xuefeng
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 212
  • [39] Candidate reference measurement procedure for determination of urea in serum by liquid chromatography-tandem mass spectrometry
    Han, Liqiao
    Huang, Xiaoting
    Zhang, Lu
    Zhang, Qiaoxuan
    Wang, Jianbing
    Lin, Haibiao
    Yan, Jun
    Zhuang, Junhua
    Huang, Xianzhang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 : 124 - 129
  • [40] Simultaneous Determination of Cortisol and Cortisone from Human Serum by Liquid Chromatography-Tandem Mass Spectrometry
    Lee, Sanghoo
    Lim, Hwan-Sub
    Shin, Hye-Jin
    Kim, Seol-A
    Park, Jimyeong
    Kim, Hyun-Chul
    Kim, Hyogyeong
    Kim, Hyung Joo
    Kim, Yun-Tae
    Lee, Kyoung-Ryul
    Kim, Young-Jin
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2014, 2014