Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry

被引:69
作者
Turpeinen, Ursula [1 ]
Hamalainen, Esa [1 ,2 ]
Stenman, Ulf-Hakan [2 ]
机构
[1] HUSLAB, Lab Womens Clin, Helsinki 00029, Finland
[2] Univ Helsinki, Dept Clin Chem, SF-00100 Helsinki, Finland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 862卷 / 1-2期
关键词
serum aldosterone; LC-MS/MS; ESI; Electrospray ionization mass spectrometry; API; 3000; RIA;
D O I
10.1016/j.jchromb.2007.11.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of serum aldosterone is clinically important in the diagnosis of hypertension.)While isotope dilution gas chromatography-mass spectrometry (ID-GC-MS) provides reliable results, it requires derivatization and is lengthy and time-consuming. Detection by liquid chromatography-mass spectrometry (LC-MS) is a potentially superior method. The analysis utilizes 0.5 mL of serum. The samples were extracted with dichloromethane-ether. The extract was evaporated to dryness and aldosterone was analyzed by LC-MS/MS operating in the negative mode ESI after separation on a reversed-phase column. Aldosterone was also measured by RIA. The calibration curves for analysis of serum aldosterone exhibited consistent linearity and reproducibility in the range of 60-3000 pmol/L. Interassay CVs were 4.3-7.5% at aldosterone concentrations of 97-993 pmol/L. The lower limit of quantitation (LOQ) was 30 pmol/L (signal to noise ratio = 10). The mean recovery of the analyte added to serum ranged from 95 to 102%. The regression equation by LC-MS/MS (x) and RIA (y) method was: y = 1.33x + 185 (r = 0.95; n = 124). Sensitivity and specificity of the LC-MS/MS method for serum aldosterone offer advantages over GC-MS by eliminating derivatization. The novel method is rapid, reliable and simple to perform with a routine LC-MS/MS spectrometer. The sensitivity is adequate for patient samples. Aldosterone concentrations reported by nonextraction RIA were consistently higher than those produced by LC-MS/MS. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 12 条
  • [1] BAYARD F, 1970, J CLIN ENDOCR METAB, V31, P1
  • [2] Aldosterone and renin measurements
    Cartledge, S
    Lawson, N
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 : 262 - 278
  • [3] A reference method for the analysis of aldosterone in blood by high-performance liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry
    Fredline, VF
    Taylor, PJ
    Dodds, HM
    Johnson, AG
    [J]. ANALYTICAL BIOCHEMISTRY, 1997, 252 (02) : 308 - 313
  • [4] PRIMARY ALDOSTERONISM - HYPERTENSION WITH A GENETIC-BASIS
    GORDON, RD
    KLEMM, SA
    TUNNY, TJ
    STOWASSER, M
    [J]. LANCET, 1992, 340 (8812) : 159 - 161
  • [5] Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photo spray ionization tandem mass spectrometry
    Guo, Tiedong
    Taylor, Robert L.
    Singh, Ravinder J.
    Soldin, Steven J.
    [J]. CLINICA CHIMICA ACTA, 2006, 372 (1-2) : 76 - 82
  • [6] Nontraditional aspects of aldosterone physiology
    Ngarmukos, C
    Grekin, RJ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2001, 281 (06): : E1122 - E1127
  • [7] Automated chemiluminescence-immunoassay for aldosterone during dynamic testing: Comparison to radioimmunoassays with and without extraction steps
    Schirpenbach, Caroline
    Seiler, Lysann
    Maser-Gluth, Christiane
    Beuschlein, Felix
    Reincke, Martin
    Bidlingmaier, Martin
    [J]. CLINICAL CHEMISTRY, 2006, 52 (09) : 1749 - 1755
  • [8] DETERMINATION OF STEROID-HORMONES BY THE USE OF ISOTOPE DILUTION MASS SPECTROMETRY - DEFINITIVE METHOD IN CLINICAL-CHEMISTRY
    SIEKMANN, L
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1979, 11 (01) : 117 - 123
  • [9] STABLER TV, 1991, CLIN CHEM, V37, P1987
  • [10] DETERMINATION OF ALDOSTERONE IN HUMAN SERUM BY ISOTOPE-DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY USING A NEW HEPTAFLUOROBUTYRYL DERIVATIVE
    STOCKL, D
    REINAUER, H
    THIENPONT, LM
    DELEENHEER, AP
    [J]. BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (11) : 657 - 664