Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo

被引:39
作者
Vliegenthart, R
Song, B
Hofman, A
Witteman, JCM
Oudkerk, M
机构
[1] Univ Groningen, Univ Groningen Hosp, Dept Radiol, NL-9713 GZ Groningen, Netherlands
[2] Erasmus MC, Daniel Den Hoed Clin, Dept Epidemiol, Rotterdam, Netherlands
[3] Erasmus MC, Daniel Den Hoed Clin, Dept Biostat, Rotterdam, Netherlands
[4] 1 Univ Hosp, Dept Radiol, Chengdu, Peoples R China
关键词
coronary vessels; calcification; CT;
D O I
10.1148/radiol.2292021305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of electron-beam computed tomography (CT) with 3.0- and 1.5-mm section thickness for calcium quantification and the prevalence of coronary calcifications with each. MATERIALS AND METHODS: Electron-beam CT images were acquired with nonoverlapping 1.5- and 3.0-mm section thickness. Scans were obtained in an anthropomorphic thorax phantom with calcium cylinders of different sizes and densities, as well as in 1,302 study participants. A calcified lesion was defined as a minimum of 2 pixels (area, 0.52 mm(2)) with a minimum attenuation of 130 HU. The calcified lesions were quantified by means of a volumetric method with isotropic interpolation. From the phantom scans mean volume scores, SDs, and measurement variations were calculated. From the participant scans, median volume scores and interquartile ranges were calculated. Participants were classified in categories based on cutoff levels for volume score quartiles for the 1.5-mm scans. An intraclass correlation coefficient (K value) was calculated as a measure of correlation between categories. RESULTS: In the phantom, deviations of calculated volumes from the true cylinder volumes and measurement variations were generally higher for the 3.0-mm protocol than for the 1.5-mm protocol. In the participants, the median volume score was 100 mm(3) (interquartile range, 11-409 mm(3)) for the 3.0-mm protocol and 144 mm(3) (interquartile range, 35-513 mm(3)) for the 1.5-mm protocol. Agreement between classifications of volume scores for the 1.5- and 3.0-mm scans was good (K = 0.62, P <.001). Compared with the quartile classification for the 1.5-mm scan, however, classifications for 370 (28%) participants were put in a different category with the 3.0-mm protocol. CONCLUSION: In a phantom, electron-beam CT scans with 3.0-mm section thickness yield less accurate estimates of calcified volume than do 1.5-mm scans. Electron-beam CT protocols with thinner sections considerably affect classification of individuals on the basis of the amount of coronary calcification depicted. (C) RSNA, 2003.
引用
收藏
页码:520 / 525
页数:6
相关论文
共 45 条
  • [41] Electron beam CT versus 16-slice spiral CT: how accurately can we measure coronary artery calcium volume?
    Jun Horiguchi
    Yun Shen
    Yuji Akiyama
    Nobuhiko Hirai
    Kousuke Sasaki
    Minoru Ishifuro
    Katsuhide Ito
    European Radiology, 2006, 16 : 374 - 380
  • [42] Iterative Image Reconstruction Techniques for CT Coronary Artery Calcium Quantification: Comparison with Traditional Filtered Back Projection in Vitro and in Vivo
    Schindler, Andreas
    Vliegenthart, Rozemarijn
    Schoepf, U. Joseph
    Blanke, Philipp
    Ebersberger, Ullrich
    Cho, Young Jun
    Allmendinger, Thomas
    Vogt, Sebastian
    Raupach, Rainer
    Fink, Christian
    Saam, Tobias
    Bamberg, Fabian
    Nikolaou, Konstantin
    Apfaltrer, Paul
    RADIOLOGY, 2014, 270 (02) : 387 - 393
  • [43] Performance assessment of an artificial intelligence-based coronary artery calcium scoring algorithm in non-gated chest CT scans of different slice thickness
    Yin, Kejie
    Chen, Wenping
    Qin, Guochu
    Liang, Jing
    Bao, Xue
    Yu, Hongming
    Li, Hui
    Xu, Jianhua
    Chen, Xingbiao
    Wang, Yujie
    Savage, Rock H.
    Schoepf, U. Joseph
    Mu, Dan
    Zhang, Bing
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (08) : 5708 - 5720
  • [44] Coronary Artery Calcium Scoring Does Not Add Prognostic Value to Standard 64-Section CT Angiography Protocol in Low-Risk Patients Suspected of Having Coronary Artery Disease
    Kwon, Sung Woo
    Kim, Young Jin
    Shim, Jaemin
    Sung, Ji Min
    Han, Mi Eun
    Kang, Dong Won
    Kim, Ji-Ye
    Choi, Byoung Wook
    Chang, Hyuk-Jae
    RADIOLOGY, 2011, 259 (01) : 92 - 99
  • [45] Coronary Computed Tomography Angiography-Based Calcium Scoring In Vitro and In Vivo Validation of a Novel Virtual Noniodine Reconstruction Algorithm on a Clinical, First-Generation Dual-Source Photon Counting-Detector System
    Emrich, Tilman
    Aquino, Gilberto
    Schoepf, U. Joseph
    Braun, Franziska M.
    Risch, Franka
    Bette, Stefanie J.
    Woznicki, Piotr
    Decker, Josua A.
    O'Doherty, Jim
    Brandt, Verena
    Allmendinger, Thomas
    Nowak, Tristan
    Schmidt, Bernhard
    Flohr, Thomas
    Kroencke, Thomas J.
    Scheurig-Muenkler, Christian
    Varga-Szemes, Akos
    Schwarz, Florian
    INVESTIGATIVE RADIOLOGY, 2022, 57 (08) : 536 - 543