Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo

被引:39
作者
Vliegenthart, R
Song, B
Hofman, A
Witteman, JCM
Oudkerk, M
机构
[1] Univ Groningen, Univ Groningen Hosp, Dept Radiol, NL-9713 GZ Groningen, Netherlands
[2] Erasmus MC, Daniel Den Hoed Clin, Dept Epidemiol, Rotterdam, Netherlands
[3] Erasmus MC, Daniel Den Hoed Clin, Dept Biostat, Rotterdam, Netherlands
[4] 1 Univ Hosp, Dept Radiol, Chengdu, Peoples R China
关键词
coronary vessels; calcification; CT;
D O I
10.1148/radiol.2292021305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of electron-beam computed tomography (CT) with 3.0- and 1.5-mm section thickness for calcium quantification and the prevalence of coronary calcifications with each. MATERIALS AND METHODS: Electron-beam CT images were acquired with nonoverlapping 1.5- and 3.0-mm section thickness. Scans were obtained in an anthropomorphic thorax phantom with calcium cylinders of different sizes and densities, as well as in 1,302 study participants. A calcified lesion was defined as a minimum of 2 pixels (area, 0.52 mm(2)) with a minimum attenuation of 130 HU. The calcified lesions were quantified by means of a volumetric method with isotropic interpolation. From the phantom scans mean volume scores, SDs, and measurement variations were calculated. From the participant scans, median volume scores and interquartile ranges were calculated. Participants were classified in categories based on cutoff levels for volume score quartiles for the 1.5-mm scans. An intraclass correlation coefficient (K value) was calculated as a measure of correlation between categories. RESULTS: In the phantom, deviations of calculated volumes from the true cylinder volumes and measurement variations were generally higher for the 3.0-mm protocol than for the 1.5-mm protocol. In the participants, the median volume score was 100 mm(3) (interquartile range, 11-409 mm(3)) for the 3.0-mm protocol and 144 mm(3) (interquartile range, 35-513 mm(3)) for the 1.5-mm protocol. Agreement between classifications of volume scores for the 1.5- and 3.0-mm scans was good (K = 0.62, P <.001). Compared with the quartile classification for the 1.5-mm scan, however, classifications for 370 (28%) participants were put in a different category with the 3.0-mm protocol. CONCLUSION: In a phantom, electron-beam CT scans with 3.0-mm section thickness yield less accurate estimates of calcified volume than do 1.5-mm scans. Electron-beam CT protocols with thinner sections considerably affect classification of individuals on the basis of the amount of coronary calcification depicted. (C) RSNA, 2003.
引用
收藏
页码:520 / 525
页数:6
相关论文
共 45 条
  • [31] Simple single-section method for measurement of left and right atrial volumes with electron-beam CT
    Budoff, MJ
    Mao, SS
    Wang, SJ
    Bakhsheshi, H
    Brundage, BH
    ACADEMIC RADIOLOGY, 1999, 6 (08) : 481 - 486
  • [32] Coronary microvascular functional reserve:: Quantification of long-term changes with electron-beam CT -: Preliminary results in a porcine model
    Möhlenkamp, S
    Behrenbeck, TR
    Lerman, A
    Lerman, LO
    Pankratz, VS
    Sheedy, PF
    Weaver, AL
    Ritman, EL
    RADIOLOGY, 2001, 221 (01) : 229 - 236
  • [33] Improved reproducibility of coronary artery calcium scoring by electron beam tomography with a new electrocardiographic trigger method
    Mao, SS
    Budoff, MJ
    Bakhsheshi, H
    Liu, SCK
    INVESTIGATIVE RADIOLOGY, 2001, 36 (07) : 363 - 367
  • [34] Effects of window and threshold levels on the accuracy of three-dimensional rendering techniques in coronary artery electron-beam CT angiography
    Lu, B
    Dai, RP
    Jiang, SL
    Bal, H
    He, S
    Zhuang, N
    Sun, XG
    Budoff, MJ
    ACADEMIC RADIOLOGY, 2001, 8 (08) : 754 - 761
  • [35] Baseline heart rate-adjusted electrocardiographic triggering for coronary artery electron-beam CT angiography
    Lu, B
    Zhuang, N
    Mao, SS
    Child, J
    Carson, S
    Budoff, MJ
    RADIOLOGY, 2004, 233 (02) : 590 - 595
  • [36] CORONARY-ARTERY STENOSES - 3-DIMENSIONAL IMAGING WITH ELECTROCARDIOGRAPHICALLY TRIGGERED, CONTRAST AGENT-ENHANCED, ELECTRON-BEAM CT
    MOSHAGE, WEL
    ACHENBACH, S
    SEESE, B
    BACHMANN, K
    KIRCHGEORG, M
    RADIOLOGY, 1995, 196 (03) : 707 - 714
  • [37] Coronary calcium scoring using 16-row multislice computed tomography -: Nonenhanced versus contrast-enhanced studies in vitro and in vivo
    Mühlenbruch, G
    Wildberger, JE
    Koos, R
    Das, M
    Flohr, TG
    Niethammer, M
    Weiss, C
    Günther, RW
    Mahnken, AH
    INVESTIGATIVE RADIOLOGY, 2005, 40 (03) : 148 - 154
  • [38] Relation of Depressive Symptoms With Coronary Artery Calcium Determined by Electron-Beam Computed Tomography (from the Rancho Bernardo Study)
    Bellettiere, John
    Kritz-Silverstein, Donna
    Laughlin, Gail A.
    LaCroix, Andrea Z.
    McEvoy, Linda K.
    Barrett-Connor, Elizabeth
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (03) : 325 - 332
  • [39] Photon Counting Detector CT-Based Virtual Noniodine Reconstruction Algorithm for In Vitro and In Vivo Coronary Artery Calcium Scoring: Impact of Virtual Monoenergetic and Quantum Iterative Reconstructions
    Fink, Nicola
    Zsarnoczay, Emese
    Schoepf, U. Joseph
    Griffith III, Joseph P. P.
    Wolf, Elias V.
    O'Doherty, Jim
    Suranyi, Pal
    Baruah, Dhiraj
    Kabakus, Ismail M.
    Ricke, Jens
    Varga-Szemes, Akos
    Emrich, Tilman
    INVESTIGATIVE RADIOLOGY, 2023, 58 (09) : 673 - 680
  • [40] Electron beam CT versus 16-slice spiral CT: how accurately can we measure coronary artery calcium volume?
    Horiguchi, J
    Shen, Y
    Akiyama, Y
    Hirai, N
    Sasaki, K
    Ishifuro, M
    Ito, K
    EUROPEAN RADIOLOGY, 2006, 16 (02) : 374 - 380