The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study

被引:19
|
作者
Moga, Iustin [1 ,3 ]
Konstantinidis, George [1 ,4 ]
Wong, Ivan Ho-Bun [1 ,2 ]
机构
[1] Nova Scotia Hlth Author, Halifax, NS, Canada
[2] Dalhousie Univ, 5955 Vet Mem Lane, Halifax, NS B3H 2E1, Canada
[3] Nova Scotia Hlth Author, Dept Orthoped Surg, Halifax, NS, Canada
[4] Royal Darwin Hosp, Darwin, NT, Australia
来源
ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE | 2018年 / 6卷 / 09期
关键词
portal safety; cadaveric study; shoulder arthroscopic surgery; shoulder instability; bone loss; Latarjet; anatomic glenoid reconstruction; musculoskeletal nerve; axillary nerve; cephalic vein; subclavian artery; subclavian vein; inside-out; subscapularis split; far medial portal; SHORT-TERM COMPLICATIONS; LATARJET PROCEDURE; SHOULDER ARTHROSCOPY; INSTABILITY;
D O I
10.1177/2325967118795404
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: An arthroscopic technique for anatomic glenoid reconstruction has been proposed for the treatment of glenohumeral bone loss in patients with recurrent shoulder instability. This technique is proposed as an alternative to open techniques as well as to the technically challenging arthroscopic Latarjet procedure. In arthroscopic anatomic glenoid reconstruction, a distal tibial allograft is inserted through a novel far medial portal, superior to the subscapularis tendon and lateral to the conjoint tendon. Purpose: To evaluate the safety of the far medial arthroscopic portal for anatomic glenoid reconstruction in a cadaveric study. Study Design: Descriptive laboratory study. Methods: Ten cadaveric shoulder specimens were dissected after inside-out medial arthroscopic portal insertion in the lateral decubitus position for arthroscopic anatomic glenoid reconstruction. A single observer performed 3 measurements on each specimen with a digital caliper (to the nearest 0.1 mm) from the medial portal to neurovascular structures, and the mean (SD) and the range were calculated. The anthropometric data of the cadaveric specimens were also collected. Results: The mean distances between the far medial arthroscopic portal and sensitive anatomic structures were as follows: 50.79 13.69 mm from the musculocutaneous nerve, 46.28 +/- 9.64 mm from the axillary nerve, 6.71 +/- 8.52 mm from the cephalic vein, and 48.52 +/- 7.22 mm from the subclavian artery and vein. The mean size of the medial arthroscopic portal was 25.60 mm. In all cases, the subscapularis muscle was intact. Conclusion: The far medial arthroscopic portal for anatomic glenoid reconstruction without a subscapularis split presents a minimal risk to most neurovascular structures during bony reconstruction of the glenoid surface in patients with anterior shoulder instability. The only anatomic structure at risk is the cephalic vein, while the axillary and musculocutaneous nerves are at a safe distance away from the portal, based on previous shoulder arthroscopic portal safety studies in the literature. Clinical Relevance: Arthroscopic anatomic glenoid reconstruction using a distal tibial allograft is increasing in popularity for the treatment of anterior shoulder instability with significant bone loss. Being a relatively new technique, the safety of it has yet to be established. This study aimed to demonstrate the safety of a new portal used for arthroscopic anatomic glenoid reconstruction.
引用
收藏
页数:4
相关论文
共 46 条
  • [41] Anatomical relationships of the transmuscular portal to its surrounding structures in arthroscopic treatment of superior labrum anterior posterior lesions: A cadaveric study and preliminary report
    Ozler, Turhan
    Kocadal, Onur
    Zeybek, Gulsah
    Kiray, Amac
    Meric, Gokhan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2021, 55 (01) : 38 - 41
  • [42] Is It Possible to Perform Fifth Carpometacarpal Joint Arthroscopy? Cadaveric Study on Its Feasibility, Safety, and Potential Hazards in Portal Creation
    Koo, Siu Cheong Jeffrey Justin
    Pang, Henry
    Ho, Pak Cheong
    JOURNAL OF WRIST SURGERY, 2023, 12 (02) : 155 - 160
  • [43] ?Nearly off-track lesions?or a short distance from the medial edge of the Hill-Sachs lesion to the medial edge of the glenoid track does not seem to be accurate in predicting recurrence after an arthroscopic Bankart repair in a military population: a case-control study
    Verweij, Lukas P. E.
    van Iersel, Theodore P.
    van Deurzen, Derek F. P.
    van den Bekerom, Michel P. J.
    Floor, Sebastiaan
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (04) : e145 - e152
  • [44] Arthroscopic Bankart repair: how many knotless anchors do we need for anatomic reconstruction of the shoulder?-a prospective randomized controlled study
    Buckup, Johannes
    Welsch, Frederic
    Petchennik, Stanislav
    Klug, Alexander
    Gramlich, Yves
    Hoffmann, Reinhard
    Stein, Thomas
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (05) : 1285 - 1293
  • [45] A Triple-Strand Anatomic Medial Collateral Ligament Reconstruction Restores Knee Stability More Completely Than a Double-Strand Reconstruction: A Biomechanical Study In Vitro
    Miyaji, Nobuaki
    Holthof, Sander R.
    Bastos, Ricardo P. S.
    Ball, Simon, V
    Espregueira-Mendes, Joao
    Williams, Andy
    Amis, Andrew A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (07) : 1832 - 1842
  • [46] A novel transverse talar tunnel achieved less vessel damage and better drilling safety for ATFL reconstruction: a cadaveric study with three-dimensional microCT
    Wang, Dingyu
    Shen, Zhongcheng
    Yang, Shuai
    Zhang, Bo
    Li, Yanzhang
    Fang, Yin
    Jiao, Chen
    Guo, Qinwei
    Zhang, Weiguang
    Jiang, Dong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2020, 12 (12): : 8050 - 8058