MR imaging assessment of changes in renal function with renal artery stent placement in swine

被引:6
作者
Park, Jonathan K.
Rhee, Thomas K.
Cashen, Ty A.
Shin, Wanyong
Resnick, Scott A.
Gehl, James A.
Schirf, Brian E.
Wang, Dingxin
Larson, Andrew C.
Carroll, Timothy J.
Omary, Reed A.
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
D O I
10.1016/j.jvir.2007.08.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively test the hypothesis that magnetic resonance (MR) imaging can detect changes in renal function at the time of renal artery stent placement in a swine model of renal artery stenosis (RAS). MATERIALS AND METHODS: In this animal care and use committee-approved study, hemodynamically significant (>50%) RAS was surgically induced in six pigs. MR imaging was employed for assessment of the anatomic and physiologic changes induced by fluoroscopically guided stent placement. With MR imaging, we assessed changes in renal blood flow (RBF), extraction fraction (EF), and single-kidney glomerular filtration rate (skGFR) during the procedure. Arterial diameter stenosis before and after stent placement was assessed with x-ray digital subtraction angiography (DSA). Mean changes in functional and anatomic parameters were compared with the Wilcoxon matched-pairs test, with an a level of 0.05. RESULTS: There was no significant change in mean RBF after stent deployment (P =.44). Mean EF increased from 0.19 +/- 0.08 before stent placement to 0.31 +/- 0.17 after stent placement (P =.16). Mean skGFR measurements were 25 mL/min +/- 16 before stent placement and 41 mL/min +/- 28 after stent placement (P <.05). According to x-ray DSA measurements, mean stenosis measurements were 60% +/- 12% before stent placement and 24% +/- 16% after stent placement (P <.02). CONCLUSIONS: In swine, MR imaging can detect immediate changes in renal function after radiographically guided stent placement for unilateral RAS. This functional MR technique may have applications in the setting of hybrid MR/x-ray DSA procedure suites.
引用
收藏
页码:1409 / 1416
页数:8
相关论文
共 50 条
[41]   Stent placement in the renal artery: Three-year experience with the Palmaz stent [J].
Henry, M ;
Amor, M ;
Henry, I ;
Ethevenot, C ;
Allaoui, M ;
Tricoche, O ;
Porte, JM ;
Touchot, N .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (03) :343-350
[42]   Renal artery revascularization: percutaneous stent placement is the standard of practice [J].
White, CJ .
VASCULAR MEDICINE, 2002, 7 (01) :3-4
[43]   Ultrasound-Guided Placement of a Renal Artery Stent Using an Intracardiac Probe for Transvascular Imaging [J].
Belohlavek, Marek ;
Jiamsripong, Panupong ;
McMahon, Eileen M. ;
Lombari, Theresa R. ;
Lerman, Lilach O. .
OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2011, 5 :215-217
[44]   Complete resolution of acute renal failure after left renal artery angioplasty and stent placement for total renal artery occlusion [J].
Rehan, Arshad ;
Almanaseer, Yassar ;
Desai, Devang M. ;
Ali, Arshad ;
Yamasaki, Hiroshi .
CARDIOLOGY, 2007, 108 (01) :51-54
[45]   Beneficial effect of renal artery angioplasty and stent placement (RASP) on severe atherosclerotic renal artery stenosis (RAS). [J].
Venkatesan, J ;
Burket, M ;
Cooper, C ;
Brewster, P ;
Kennedy, D ;
Henrich, WL .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 :A1490-A1490
[46]   Noninvasive Assessment of Renal Fibrosis with Magnetization Transfer MR Imaging: Validation and Evaluation in Murine Renal Artery Stenosis [J].
Jiang, Kai ;
Ferguson, Christopher M. ;
Ebrahimi, Behzad ;
Tang, Hui ;
Kline, Timothy L. ;
Burningham, Tyson A. ;
Mishra, Prassana K. ;
Grande, Joseph P. ;
Macura, Slobodan I. ;
Lerman, Lilach O. .
RADIOLOGY, 2017, 283 (01) :77-86
[47]   Diabetes mellitus and long-term impact on renal function in patients with renal artery stenosis receiving percutaneous transluminal renal angioplasty and stent placement [J].
Bromet, DS ;
Venzon, RP ;
Butzel, DW ;
Oswald, K ;
Kavinsky, CJ ;
Schaer, GL ;
Snell, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) :76A-76A
[48]   Mortality and Renal Replacement Therapy after Renal Artery Stent Placement for Atherosclerotic Renovascular Disease [J].
Misra, Sanjay ;
Khosla, Ankaj ;
Allred, Jake ;
Harmsen, William S. ;
Textor, Stephen C. ;
McKusick, Michael A. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (08) :1215-1224
[49]   Usefulness of renal frame count to identify the good responder of renal artery stent placement in patients with atherosclerotic renal artery stenosis with hypertension [J].
Shiba, M. ;
Nakamura, M. ;
Itaya, H. ;
Shinji, H. ;
Makino, K. ;
Nemoto, N. ;
Ito, N. ;
Wada, M. .
EUROPEAN HEART JOURNAL, 2006, 27 :121-121
[50]   Renal changes in Fabry disease: MR and sonographic correlation with renal function [J].
Glass, RB ;
Norton, KI ;
Parsons, RB ;
Rybak, L ;
Eng, CM .
RADIOLOGY, 1999, 213P :464-464