Total endovascular repair of an intraoperative stent-graft deployed in the false lumen of Stanford type A aortic dissection: A case report

被引:7
作者
Li, Xu-Ran [1 ]
Tong, Yuan-Hao [1 ]
Li, Xiao-Qiang [1 ]
Liu, Chang-Jian [1 ]
Liu, Chen [1 ]
Liu, Zhao [1 ]
机构
[1] Nanjing Univ, Dept Vasc Surg, Nanjing Drum Tower Hosp, Affiliated Hosp,Med Sch, 321 Zhongshan Rd, Nanjing 210008, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Type A dissection; False lumen stent graft implantation; Endovascular repair; 3D printing; Thoracoabdominal aortic dissection; Case report; METAANALYSIS;
D O I
10.12998/wjcc.v8.i5.954
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND A 46-year-old male underwent ascending aortic replacement, total arch replacement, and descending aortic stent implantation for Stanford type A aortic dissection in 2016. However, an intraoperative stent-graft was deployed in the false lumen inadvertently. This caused severe iatrogenic thoracic and abdominal aortic dissection, and the dissection involved many visceral arteries. CASE SUMMARY The patient had pain in the chest and back for 1 mo. A computed tomography scan showed that the patient had secondary thoracic and abdominal aortic dissection. The ascending aortic replacement, total arch replacement, and descending aortic stent implantation for Stanford type A aortic dissection were performed 2 years prior. An intraoperative stent-graft was deployed in the false lumen. Endovascular aneurysm repair was performed to address this intractable situation. An occluder was used to occlude the proximal end of the true lumen, and a covered stent was used to direct blood flow back to the true lumen. A three-dimensional printing technique was used in this operation to guide pre-fenestration. The computed tomography scan at the 1(st)mo after surgery showed that the thoracic and abdominal aortic dissection was repaired, with all visceral arteries remaining patent. The patient did not develop renal failure or neurological complications after surgery. CONCLUSION The total endovascular repair for false lumen stent-graft implantation was feasible and minimally invasive. Our procedures provided a new solution for stent-graft deployed in the false lumen, and other departments may be inspired by this case when they need to rescue a disastrous stent implantation.
引用
收藏
页码:954 / 962
页数:9
相关论文
共 13 条
[1]  
Chen Y, 2018, J THORACCARDIOVASCSU
[2]   Endovascular Aortic Repair Versus Open Surgical Repair for Descending Thoracic Aortic Disease A Systematic Review and Meta-Analysis of Comparative Studies [J].
Cheng, Davy ;
Martin, Janet ;
Shennib, Hani ;
Dunning, Joel ;
Muneretto, Claudio ;
Schueler, Stephan ;
Von Segesser, Ludwig ;
Sergeant, Paul ;
Turina, Marko .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10) :986-1001
[3]   Endovascular graft deployment in the false lumen of type B dissection [J].
Follis, Fabrizio ;
Filippone, Gianfranco ;
Stabile, Amerigo ;
Montalbano, Giuseppe ;
Floriano, Maria ;
Finazzo, Mario ;
Follis, Marco .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (04) :597-599
[4]   Intravascular Ultrasound-Assisted Endovascular Treatment of Mesenteric Malperfusion in a Multichannel Aortic Dissection With Full True Lumen Collapse [J].
Guo, Baolei ;
Guo, Daqiao ;
Shi, Zhenyu ;
Dong, Zhihui ;
Fu, Weiguo .
JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (01) :83-87
[5]   The International Registry of Acute Aortic Dissection (IRAD) - New insights into an old disease [J].
Hagan, PG ;
Nienaber, CA ;
Isselbacher, EM ;
Bruckman, D ;
Karavite, DJ ;
Russman, PL ;
Evangelista, A ;
Fattori, R ;
Suzuki, T ;
Oh, JK ;
Moore, AG ;
Malouf, JF ;
Pape, LA ;
Gaca, C ;
Sechtem, U ;
Lenferink, S ;
Deutsch, HJ ;
Diedrichs, H ;
Robles, JMY ;
Llovet, A ;
Gilon, D ;
Das, SK ;
Armstrong, WF ;
Deeb, GM ;
Eagle, KA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (07) :897-903
[6]   How to guide stent-graft implantation in type B aortic dissection? Comparison of angiography, transesophageal echocardiography, and intravascular ultrasound [J].
Koschyk, DH ;
Nienaber, CA ;
Knap, M ;
Hofmann, T ;
Kodolitsch, YV ;
Skriabina, V ;
Ismail, M ;
Franzen, O ;
Rehders, TC ;
Dieckmann, C ;
Lund, G ;
Reichenspurner, H ;
Meinertz, T .
CIRCULATION, 2005, 112 (09) :I260-I264
[7]   Treatment of serious complications following endovascular aortic repair for type B thoracic aortic dissection [J].
Liu, Zhao ;
Zhang, Yepeng ;
Liu, Chen ;
Huang, Dian ;
Zhang, Ming ;
Ran, Feng ;
Wang, Wei ;
Shang, Tao ;
Qiao, Tong ;
Zhou, Min ;
Liu, Changjian .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2017, 45 (05) :1574-1584
[8]   Successful endoluminal rescue of an endovascular graft unintentionally deployed in the false lumen of Stanford type B aortic dissection [J].
Ma, Xiang ;
Fu, Weiguo ;
Ma, Yi-Tong ;
Karmacharya, Ujit ;
Zhao, Jun .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (03) :E41-E45
[9]   Editor's Choice - The Impact of Early Pelvic and Lower Limb Reperfusion and Attentive Peri-operative Management on the Incidence of Spinal Cord Ischemia During Thoracoabdominal Aortic Aneurysm Endovascular Repair [J].
Maurel, B. ;
Delclaux, N. ;
Sobocinski, J. ;
Hertault, A. ;
Martin-Gonzalez, T. ;
Moussa, M. ;
Spear, R. ;
Le Roux, M. ;
Azzaoui, R. ;
Tyrrell, M. ;
Haulon, S. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 49 (03) :248-254
[10]   Serious complications following endovascular thoracic aortic stent-graft repair for type B dissection [J].
Neuhauser, Beate ;
Greiner, Andreas ;
Jaschke, Werner ;
Chemelli, Andreas ;
Fraedrich, Gustav .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (01) :58-63