Sealing Behavior in Transcatheter Bicuspid and Tricuspid Aortic Valves Replacement Through Patient-Specific Computational Modeling

被引:10
作者
Liu, Xianbao [1 ]
Fan, Jiaqi [1 ]
Mortier, Peter [2 ]
He, Yuxin [1 ]
Zhu, Qifeng [1 ]
Guo, Yuchao [1 ]
Lin, Xinping [1 ]
Li, Huajun [1 ]
Jiang, Jubo [1 ]
Rocatello, Giorgia [2 ]
Oliveira, Vanda [2 ]
Dezutter, Tim [2 ]
Sondergaard, Lars [3 ]
Wang, Jian'an [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 2, Dept Cardiol, Sch Med, Hangzhou, Peoples R China
[2] FEops, Ghent, Belgium
[3] Rigshosp, Dept Cardiol, Copenhagen, Denmark
基金
欧盟地平线“2020”;
关键词
transcatheter aortic valve replacement; bicuspid aortic valve; patient-specific computational modeling; sealing behavior; paravalvular leakage; IMPLANTATION; CLASSIFICATION; COREVALVE; STENOSIS; RAPHE; TAVI;
D O I
10.3389/fcvm.2021.732784
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) can provide unique insights in device-patient interaction. Aims: This study was to compare transcatheter aortic valve sealing behavior in patients with bicuspid aortic valves (BAV) and tricuspid aortic valves (TAV) through patient-specific computational modeling. Methods: Patient-specific computer simulation was retrospectively performed with FEops HEARTguide for TAVR patients. Simulation output was compared with postprocedural computed tomography and echocardiography to validate the accuracy. Skirt malapposition was defined by a distance larger than 1 mm based on the predicted device-patient interaction by quantifying the distance between the transcatheter heart valve (THV) skirt and the surrounding anatomical regions. Results: In total, 43 patients were included in the study. Predicted and observed THV frame deformation showed good correlation (R-2 >= 0.90) for all analyzed measurements (maximum diameter, minimum diameter, area, and perimeter). The amount of predicted THV skirt malapposition was strongly linked with the echocardiographic grading of paravalvular leakage (PVL). More THV skirt malapposition was observed for BAV cases when compared to TAV cases (22.7 vs. 15.5%, p < 0.05). A detailed analysis of skirt malapposition showed a higher degree of malapposition in the interleaflet triangles section for BAV cases as compared to TAV patients (11.1 vs. 5.8%, p < 0.05). Conclusions: Patient-specific computer simulation of TAVR can accurately predict the behavior of the Venus A-valve. BAV patients are associated with more malapposition of the THV skirt as compared to TAV patients, and this is mainly driven by more malapposition in the interleaflet triangle region.
引用
收藏
页数:11
相关论文
共 27 条
[1]   A simple method to visualize the bicuspid aortic valve pathology by cardiac computed tomography [J].
Amoretti, Francesca ;
Cerillo, Alfredo Giuseppe ;
Mariani, Massimiliano ;
Stefano, Pierluigi .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (02) :195-198
[2]   Patient-Specific Computer Modeling to Predict Aortic Regurgitation After Transcatheter Aortic Valve Replacement [J].
de Jaegere, Peter ;
De Santis, Gianluca ;
Rodriguez-Olivares, Ramon ;
Bosmans, Johan ;
Bruining, Nico ;
Dezutter, Tim ;
Rahhab, Zouhair ;
El Faquir, Nahid ;
Collas, Valerie ;
Bosmans, Bart ;
Verhegghe, Benedict ;
Ren, Claire ;
Geleinse, Marcel ;
Schultz, Carl ;
van Mieghem, Nicolas ;
De Beule, Matthieu ;
Mortier, Peter .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (05) :508-512
[3]   First-in-Human Experience With Patient-Specific Computer Simulation of TAVR in Bicuspid Aortic Valve Morphology [J].
Dowling, Cameron ;
Firoozi, Sami ;
Brecker, Stephen J. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (02) :184-192
[4]   Patient-Specific Computer Simulation of Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Morphology [J].
Dowling, Cameron ;
Bavo, Alessandra M. ;
El Faquir, Nahid ;
Mortier, Peter ;
de Jaegere, Peter ;
De Backer, Ole ;
Sondergaard, Lars ;
Ruile, Philipp ;
Mylotte, Darren ;
McConkey, Hannah ;
Rajani, Ronak ;
Laborde, Jean-Claude ;
Brecker, Stephen J. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (10)
[5]   Brain Injury After Transcatheter Replacement of Bicuspid Versus Tricuspid Aortic Valves [J].
Fan, Jiaqi ;
Fang, Xian ;
Liu, Chunhui ;
Zhu, Gangjie ;
Hou, Cody R. ;
Jiang, Jubo ;
Lin, Xinping ;
Wang, Lihan ;
He, Yuxin ;
Zhu, Qifeng ;
Ng, Stella ;
Chen, Zexin ;
Hu, Haitao ;
Liu, Xianbao ;
Wang, Jian'an ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (22) :2579-2590
[6]   Transcatheter aortic valve implantation in Asia [J].
Hon, Jimmy Kim Fatt ;
Tay, Edgar .
ANNALS OF CARDIOTHORACIC SURGERY, 2017, 6 (05) :504-509
[7]   A novel supra-annular plane to predict TAVI prosthesis anchoring in raphe-type bicuspid aortic valve disease: the LIRA plane [J].
Iannopollo, Gianmarco ;
Romano, Vittorio ;
Buzzatti, Nicola ;
De Backer, Ole ;
Sondergaard, Lars ;
Merkely, Bela ;
Prendergast, Bernard ;
Giannini, Francesco ;
Colombo, Antonio ;
Latib, Azeem ;
Granada, Juan F. ;
Chieffo, Alaide ;
Montorfano, Matteo .
EUROINTERVENTION, 2020, 16 (03) :259-+
[8]   Supra-annular sizing for transcatheter valve implantation in bicuspid aortic stenosis [J].
Jeger, Raban ;
Reuthebuch, Oliver ;
Fahrni, Gregor ;
Laborde, Jean-Claude ;
Vogel, Rolf ;
Kaiser, Christoph .
POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2018, 14 (02) :187-190
[9]   A Bicuspid Aortic Valve Imaging Classification for the TAVR Era [J].
Jilaihawi, Hasan ;
Chen, Mao ;
Webb, John ;
Himbert, Dominique ;
Ruiz, Carlos E. ;
Rodes-Cabau, Josep ;
Pache, Gregor ;
Colombo, Antonio ;
Nickenig, Georg ;
Lee, Michael ;
Tamburino, Corrado ;
Sievert, Horst ;
Abramowitz, Yigal ;
Tarantini, Giuseppe ;
Alqoofi, Faisal ;
Chakravarty, Tarun ;
Kashif, Mohammad ;
Takahashi, Nobuyuki ;
Kazuno, Yoshio ;
Maeno, Yoshio ;
Kawamori, Hiroyuki ;
Chieffo, Alaide ;
Blanke, Philipp ;
Dvir, Danny ;
Ribeiro, Henrique Barbosa ;
Feng, Yuan ;
Zhao, Zhen-Gang ;
Sinning, Jan-Malte ;
Kliger, Chad ;
Giustino, Gennaro ;
Pajerski, Basia ;
Imme, Sebastiano ;
Grube, Eberhard ;
Leipsic, Jonathon ;
Vahanian, Alec ;
Michev, Iassen ;
Jelnin, Vladimir ;
Latib, Azeem ;
Cheng, Wen ;
Makkar, Raj .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (10) :1145-1158
[10]   Morphological Characteristics of Severe Aortic Stenosis in China: Imaging Corelab Observations From the First Chinese Transcatheter Aortic Valve Trial [J].
Jilaihawi, Hasan ;
Wu, Yongjian ;
Yang, Yuejin ;
Xu, Liang ;
Chen, Mao ;
Wang, Jianan ;
Kong, Xiangqing ;
Zhang, Ruiyan ;
Wang, Moyang ;
Lv, Bin ;
Wang, Wei ;
Xu, Bo ;
Makkar, Raj R. ;
Sievert, Horst ;
Gao, Runlin .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 :752-761