False Lumen Status in Patients With Acute Aortic Dissection: A Systematic Review and Meta-Analysis

被引:84
作者
Li, Dongze [1 ]
Ye, Lei [1 ]
He, Yarong [1 ]
Cao, Xiaoping [3 ]
Liu, Jining [4 ]
Zhong, Wu [5 ]
Cao, Linghong [6 ]
Zeng, Rui [2 ]
Zeng, Zhi [1 ]
Wan, Zhi [1 ]
Cao, Yu [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Emergency Med, 37 Guoxue Rd, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Cardiol, Chengdu, Peoples R China
[3] North Sichuan Med Coll, Affiliated Hosp, Dept Emergency Med, Nanchong, Peoples R China
[4] Mianyang Cent Hosp, Dept Emergency Med, Mianyang, Peoples R China
[5] Luzhou Med Coll, Affiliated Hosp, Dept Emergency Med, Luzhou, Peoples R China
[6] Zigong 4 Peoples Hosp, Dept Emergency Med, Zigong, Peoples R China
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2016年 / 5卷 / 05期
基金
中国国家自然科学基金;
关键词
aortic dissection; false lumen; meta-analysis; thrombosis; LONG-TERM MORTALITY; INTERNATIONAL REGISTRY; INTRALUMINAL THROMBUS; OUTCOMES; MANAGEMENT; INSIGHTS; SURVIVAL; ANEURYSM;
D O I
10.1161/JAHA.115.003172
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The long-term association between the status of the false lumen and poor patient outcomes in acute aortic dissection (AAD) remains unclear. This systematic review and meta-analysis investigated whether the status of the false lumen was a predictor of poor long-term survival in AAD. Methods and Results-Eleven cohort studies (2924 participants) exploring the association between the false lumen status and long-term outcomes (>1 year) in AAD were included. All studies reported multivariate-adjusted hazard ratios (HRs) with 95% CIs for long-term outcomes, according to false lumen status. Pooled HRs for mortality and aortic events were computed and weighted using generic inverse-variance and random-effect modeling. Residual patent false lumen was an independent predictor of long-term mortality in AAD type A (HR, 1.71; 95% CI, 1.16-2.52; P=0.007) and type B (HR, 2.79; 95% CI, 1.80-4.32; P<0.001). AAD patients with residual patent false lumen exhibited an increased risk of aortic events (HR, 5.43; 95% CI, 2.95-9.99; P<0.001). Partial false lumen thrombosis was independently associated with long-term mortality in type B AAD (HR, 2.24; 95% CI, 1.37-3.65; P=0.001). This association was not observed in AAD type A patients (HR, 1.75; 95% CI, 0.88-3.45; P=0.211). Conclusions-The false lumen status influences late outcomes in AAD. Residual patent false lumen is independently associated with poor long-term survival in AAD. However, only type B AAD patients with partial false lumen thrombosis had an increased late mortality risk.
引用
收藏
页数:10
相关论文
共 36 条
[1]   Outcomes of Patients With Acute Type B (DeBakey III) Aortic Dissection A 13-Year, Single-Center Experience [J].
Afifi, Rana O. ;
Sandhu, Harleen K. ;
Leake, Samuel S. ;
Boutrous, Mina L. ;
Kumar, Varsha, III ;
Azizzadeh, Ali ;
Charlton-Ouw, Kristofer M. ;
Saqib, Naveed U. ;
Nguyen, Tom C. ;
Miller, Charles C., III ;
Safi, Hazim J. ;
Estrera, Anthony L. .
CIRCULATION, 2015, 132 (08) :748-754
[2]   Vascular bed-specific thrombosis [J].
Aird, W. C. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 :283-291
[3]   Effects of the patent false lumen on the long-term outcome Iq of type B acute aortic dissection [J].
Akutsu, K ;
Nejima, J ;
Kiuchi, K ;
Sasaki, K ;
Ochi, M ;
Tanaka, K ;
Takano, T .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (02) :359-366
[4]   False lumen patency as a predictor of late outcome in aortic dissection [J].
Bernard, Y ;
Zimmermann, H ;
Chocron, S ;
Litzler, JF ;
Kastler, B ;
Etievent, JP ;
Meneveau, N ;
Schiele, F ;
Bassand, JP .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (12) :1378-1382
[5]   Early and late outcomes of acute type A aortic dissection: analysis of risk factors in 487 consecutive patients [J].
Chiappini, B ;
Schepens, M ;
Tan, E ;
Amore, AD ;
Morshuis, W ;
Dossche, K ;
Bergonzini, M ;
Camurri, N ;
Reggiani, LB ;
Marinelli, G ;
Di Bartolomeo, R .
EUROPEAN HEART JOURNAL, 2005, 26 (02) :180-186
[6]   A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging [J].
Clough, Rachel E. ;
Waltham, Matthew ;
Giese, Daniel ;
Taylor, Peter R. ;
Schaeffter, Tobias .
JOURNAL OF VASCULAR SURGERY, 2012, 55 (04) :914-923
[7]   Four-dimensional, flow-sensitive magnetic resonance imaging of blood flow patterns in thoracic aortic dissections [J].
Francois, Christopher J. ;
Markl, Michael ;
Schiebler, Mark L. ;
Niespodzany, Eric ;
Landgraf, Benjamin R. ;
Schlensak, Christian ;
Frydrychowicz, Alex .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (05) :1359-1366
[8]   The International Registry of Acute Aortic Dissection (IRAD) - New insights into an old disease [J].
Hagan, PG ;
Nienaber, CA ;
Isselbacher, EM ;
Bruckman, D ;
Karavite, DJ ;
Russman, PL ;
Evangelista, A ;
Fattori, R ;
Suzuki, T ;
Oh, JK ;
Moore, AG ;
Malouf, JF ;
Pape, LA ;
Gaca, C ;
Sechtem, U ;
Lenferink, S ;
Deutsch, HJ ;
Diedrichs, H ;
Robles, JMY ;
Llovet, A ;
Gilon, D ;
Das, SK ;
Armstrong, WF ;
Deeb, GM ;
Eagle, KA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (07) :897-903
[9]  
Higgins J.P.T., 2020, SURGERY, DOI DOI 10.1016/J.SURG.2009.06.030
[10]   4D Flow CMR in Assessment of Valve-Related Ascending Aortic Disease [J].
Hope, Michael D. ;
Hope, Thomas A. ;
Crook, Stephen E. S. ;
Ordovas, Karen G. ;
Urbania, Thomas H. ;
Alley, Marc T. ;
Higgins, Charles B. .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (07) :781-787