Development of a microfluidic device for determination of cell osmotic behavior and membrane transport properties

被引:35
作者
Chen, Hslu-hung [1 ]
Purtteman, Jester J. P. [1 ]
Heimfeld, Shelly [3 ]
Folch, Albert [1 ,2 ]
Gao, Dayong [1 ,4 ,5 ]
机构
[1] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Fred Hutchinson Canc Res Ctr, Bone Marrow Transplant Program, Seattle, WA 98104 USA
[4] Univ Kentucky, Dept Mech Engn, Lexington, KY 40506 USA
[5] Univ Kentucky, Ctr Biomed Engn, Lexington, KY 40506 USA
基金
美国国家卫生研究院;
关键词
microfluidic; perfusion system; RBL-1; permeability coefficient of water; permeability coefficient of Me2SO; monolayer; soft lithography;
D O I
10.1016/j.cryobiol.2007.08.001
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
An understanding of cell osmotic behavior and membrane transport properties is indispensable for cryobiology research and development of cell-type-specific, optimal cryopreservation conditions. A microfluidic perfusion system is developed here to measure the kinetic changes of cell volume under various extracellular conditions, in order to determine cell osmotic behavior and membrane transport properties. The system is fabricated using soft lithography and is comprised of microfluidic channels and a perfusion chamber for trapping cells. During experiments, rat basophilic leukemia (RBL-1 line) cells were injected into the inlet of the device, allowed to flow downstream, and were trapped within a perfusion chamber. The fluid continues to flow to the outlet due to suction produced by a Hamilton Syringe. Two sets of experiments have been performed: the cells were perfused by (1) hypertonic solutions with different concentrations of non-permeating solutes and (2) solutions containing a permeating cryoprotective agent (CPA), dimethylsulfoxide (Me2SO), plus non-permeating solute (sodium chloride (NaCl)), respectively. From experiment (1), cell osmotically inactive volume (V-b) and the permeability coefficient of water (L,) for RBL cells are determined to be 41% [n = 18, correlation coefficient (r(2)) of 0.903] of original/ isotonic volume, and 0.32 0.05 mu m/min/atm (n = 8, r(2) > 0.963), respectively, for room temperature (22 degrees C). From experiment (2), the permeability coefficient of water (L,) and of Me2SO (P,) for RBL cells are 0.38 +/- 0.09 mu m/min/atm and (0.49 +/- 0.13) x 10(-3) cm/min (n = 5, r(2) > 0.86), respectively. We conclude that this device enables us to: (1) readily monitor the changes of extracellular conditions by perfusing single or a group of cells with prepared media; (2) confine cells (or a cell) within a monolayer chamber, which prevents imaging ambiguity, such as cells overlapping or moving out of the focus plane; (3) study individual cell osmotic response and determine cell membrane transport properties; and (4) reduce labor requirements for its disposability and ensure low manufacturing costs. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:200 / 209
页数:10
相关论文
共 42 条
[1]  
[Anonymous], 1952, PERMEABILITY NATURAL
[2]   Optical trapping, manipulation, and sorting of cells and colloids in microfluidic systems with diode laser bars [J].
Applegate, RW ;
Squier, J ;
Vestad, T ;
Oakey, J ;
Marr, DWM .
OPTICS EXPRESS, 2004, 12 (19) :4390-4398
[3]   PERMEATION OF GLYCEROL AND PROPANE-1,2-DIOL INTO HUMAN PLATELETS [J].
ARNAUD, FG ;
PEGG, DE .
CRYOBIOLOGY, 1990, 27 (02) :107-118
[4]   Volume cytometry: Microfluidic sensor for high-throughput screening in real time [J].
Ateya, DA ;
Sachs, F ;
Gottlieb, PA ;
Besch, S ;
Hua, SZ .
ANALYTICAL CHEMISTRY, 2005, 77 (05) :1290-1294
[5]  
CHAO PG, 2006, AM J PHYSIOL-CELL PH, V291, P718
[6]  
CRITSER JK, 1988, FERTIL STERIL, V50, P314
[7]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[8]   PREVENTION OF OSMOTIC INJURY TO HUMAN SPERMATOZOA DURING ADDITION AND REMOVAL OF GLYCEROL [J].
GAO, DY ;
LIU, J ;
LIU, C ;
MCGANN, LE ;
WATSON, PF ;
KLEINHANS, FW ;
MAZUR, P ;
CRITSER, ES ;
CRITSER, JK .
HUMAN REPRODUCTION, 1995, 10 (05) :1109-1122
[9]  
GAO DY, 1994, J REPROD FERTIL, V102, P385, DOI 10.1530/jrf.0.1020385
[10]   Development of a novel microperfusion chamber for determination of cell membrane transport properties [J].
Gao, DY ;
Benson, CT ;
Liu, C ;
McGrath, JJ ;
Critser, ES ;
Critser, JK .
BIOPHYSICAL JOURNAL, 1996, 71 (01) :443-450