Diagnostic Performance of Diffusion Tensor Imaging with Readout-segmented Echo-planar Imaging for Invasive Breast Cancer: Correlation of ADC and FA with Pathological Prognostic Markers

被引:30
作者
Yamaguchi, Ken [1 ]
Nakazono, Takahiko [1 ]
Egashira, Ryoko [1 ]
Komori, Yoshiaki [2 ]
Nakamura, Jun [3 ]
Noguchi, Tomoyuki [1 ,4 ]
Irie, Hiroyuki [1 ]
机构
[1] Saga Univ, Dept Radiol, Fac Med, 5-1-1 Nabeshima, Saga 8498501, Japan
[2] Siemens Japan KK Res & Collaborat Dept, Tokyo, Japan
[3] Saga Univ, Dept Surg, Fac Med, Saga, Japan
[4] Natl Ctr Global Hlth & Med NCGM, Dept Radiol, Tokyo, Japan
关键词
breast; MRI; diffusion-weighted imaging; readout-segmented echo planar imaging; diffusion tensor imaging; COEFFICIENT VALUES; DUCTAL CARCINOMA; MR MAMMOGRAPHY; 3.0; TESLA; LESIONS; 3T; PARAMETERS; WOMEN;
D O I
10.2463/mrms.mp.2016-0037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the diagnostic performance of readout-segmented echo-planar diffusion tensor imaging (DTI based on rs-EPI) for breast cancer and to determine the correlation between the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values obtained from DTI based on rs-EPI with prognostic markers of invasive breast cancer. Materials and Methods: This retrospective study examined 80 pathologically proven breast lesions (22 benign and 58 malignant lesions) of 80 patients who underwent both diffusion-weighted imaging based on single-shot echo-planar imaging (DWI based on ss-EPI) and DTI based on rs-EPI with b-values of 0 and 1000. We identified and compared the diagnostic performances of the DWI based on ss-EPI and the DTI based on rs-EPI using ADCs by conducting a receiver-operating-characteristics (ROC) analysis. We determined the correlations between the ADCs and the prognostic markers and those of the FA values and the same markers. Results: The median ADCs of the benign and malignant lesions based on the ss-EPI were 1.57 and 1.2 x 10(-3) mm(2)/sec, and those based on the rs-EPI were 1.53 and 1.09 x 10(-3) mm(2)/sec, respectively. The area under the curve on the ROC analysis based on rs-EPI (0.924) was greater than that based on ss-EPI (0.897). There were no significant correlations between the ADCs and the prognostic markers, but there were significant correlations between the FA values and the estrogen receptor status, a proliferative marker, the nuclear grade and the intrinsic subtype. Conclusion: For breast cancer, DTI based on rs-EPI had superior diagnostic performance compared to DWI based on ss-EPI. Compared with the ADCs, the FA values were more closely correlated with prognostic markers of invasive breast cancer.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 50 条
[31]   Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: A comprehensive comparison of image quality in single-shot echo-planar imaging [J].
Zhao, Menglong ;
Liu, Zhuang ;
Sha, Yan ;
Wang, Shenjiang ;
Ye, Xinpei ;
Pan, Yucheng ;
Wang, Shaoyu .
MAGNETIC RESONANCE IMAGING, 2016, 34 (02) :166-172
[32]   Preoperative Localization of Parathyroid Adenomas with Diffusion MR Imaging: Readout-segmented versus Single-shot Echo-planar Imaging [J].
Yamamoto, Hirotaka ;
Iima, Mami ;
Kishimoto, Yo ;
Kishimoto, Ayami Ohno ;
Koyasu, Sho ;
Yamamoto, Akira ;
Kawai, Yoshitaka ;
Yoshizawa, Akira ;
Omori, Koichi .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2023, 22 (01) :79-85
[33]   Feasibility Study of 3-T DWI of the Prostate: Readout-Segmented Versus Single-Shot Echo-Planar Imaging [J].
Li, Liang ;
Wang, Liang ;
Deng, Ming ;
Liu, Hui ;
Cai, Jie ;
Sah, Vivek Kumar ;
Liu, Jihong .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) :70-76
[34]   Evaluation of Malignant Breast Lesions Using High-resolution Readout-segmented Diffusion-weighted Echo-planar Imaging: Comparison with Pathology [J].
Kishimoto, Ayami Ohno ;
Kataoka, Masako ;
Iima, Mami ;
Honda, Maya ;
Miyake, Kanae Kawai ;
Ohashi, Akane ;
Ota, Rie ;
Kataoka, Tatsuki ;
Sakurai, Takaki ;
Toi, Masakazu ;
Togashi, Kaori .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (02) :204-215
[35]   Efficacy of a Nonrigid Image-registration Method in Comparison to Readout-segmented Echo-planar Imaging for Correcting Distortion in Diffusion-weighted Imaging [J].
Kobata, Takuya ;
Yamasaki, Tatsuya ;
Katayama, Hiroki ;
Ogawa, Kazuo .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (02) :216-221
[36]   Thyroid-Associated Orbitopathy: Evaluating Microstructural Changes of Extraocular Muscles and Optic Nerves Using Readout-Segmented Echo-Planar Imaging-Based Diffusion Tensor Imaging [J].
Chen, Huan-Huan ;
Hu, Hao ;
Chen, Wen ;
Cui, Dai ;
Xu, Xiao-Quan ;
Wu, Fei-Yun ;
Yang, Tao .
KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (03) :332-340
[37]   Readout-segmented echo-planar diffusion-weighted imaging improves geometric performance for image-guided radiation therapy of pelvic tumors [J].
Foltz, Warren D. ;
Porter, David A. ;
Simeonov, Anna ;
Aleong, Amanda ;
Jaffray, David ;
Chung, Peter ;
Han, Kathy ;
Menard, Cynthia .
RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) :525-531
[38]   Improve the image quality of orbital 3 T diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging [J].
Xu, Xiao-Quan ;
Liu, Jun ;
Hu, Hao ;
Su, Guo-Yi ;
Zhang, Yu-Dong ;
Shi, Hai-Bin ;
Wu, Fei-Yun .
CLINICAL IMAGING, 2016, 40 (04) :793-796
[39]   Application value of simultaneous multislice readout-segmented echo-planar imaging for diffusion-weighted MRI in differentiation of rectal cancer grade [J].
Zhou, Mi ;
Huang, Hongyun ;
Li, Hang ;
Yan, Guihua ;
Tang, Baijie ;
Chen, Meining ;
Wang, Yuting .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (04) :621-629
[40]   Application value of simultaneous multislice readout-segmented echo-planar imaging for diffusion-weighted MRI in differentiation of rectal cancer grade [J].
Mi Zhou ;
Hongyun Huang ;
Hang Li ;
Guihua Yan ;
Baijie Tang ;
Meining Chen ;
Yuting Wang .
Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 :621-629