NONRIGID REGISTRATION WITH DIFFERENTIAL BIAS CORRECTION USING NORMALISED MUTUAL INFORMATION

被引:3
作者
Modat, Marc [1 ]
Ridgway, Gerard R. [2 ]
Hawkes, David J. [1 ]
Fox, Nick C. [2 ]
Ourselin, Sebastien [1 ,2 ]
机构
[1] UCL, Ctr Med Image Comp, London WC1E 6BT, England
[2] UCL, Dementia Res Ctr, London WC1E 6BT, England
来源
2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO | 2010年
关键词
RF inhomogeneity; MRI intensity nonuniformity; Differential Bias Correction; Registration; Normalised Mutual Information; FREE-FORM DEFORMATIONS; INTENSITY INHOMOGENEITY; IMAGE REGISTRATION; BRAIN MRI; DEMENTIA; ACCURATE;
D O I
10.1109/ISBI.2010.5490337
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intensity inhomogeneity is an important phenomenon affecting magnetic resonance imaging, which can greatly affect computational image analysis. Bias correction algorithms are commonly used, but are imperfect, leaving residual inhomogeneity that will usually differ in serial images of the same subject. This differential bias can have a detrimental effect on further processing, such as registration and quanti cation of small longitudinal changes. We embed a differential bias field model within a non-rigid registration framework. The spatial transformation and DBC parameters are optimised concurrently using the normalised mutual information as a metric. We show significant reductions in registration error with the proposed framework.
引用
收藏
页码:356 / 359
页数:4
相关论文
共 17 条
[1]  
Andersson J LR., 2008, Fourteenth Annu Meet Organ Hum Brain Mapping, P496
[2]   Cerebral atrophy measurements using Jacobian integration: Comparison with the boundary shift integral [J].
Boyes, Richard G. ;
Rueckert, Daniel ;
Aljabar, Paul ;
Whitwell, Jennifer ;
Schott, Jonathan M. ;
Hill, Derek L. G. ;
Fox, Nicholas C. .
NEUROIMAGE, 2006, 32 (01) :159-169
[3]  
Cohen MS, 2000, HUM BRAIN MAPP, V10, P204, DOI 10.1002/1097-0193(200008)10:4<204::AID-HBM60>3.0.CO
[4]  
2-2
[5]   The boundary shift integral: An accurate and robust measure of cerebral volume changes from registered repeat MRI [J].
Freeborough, PA ;
Fox, NC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) :623-629
[6]   Correction of differential intensity inhomogeneity in longitudinal MR images [J].
Lewis, EB ;
Fox, NC .
NEUROIMAGE, 2004, 23 (01) :75-83
[7]   Nonrigid Image Registration Using Conditional Mutual Information [J].
Loeckx, Dirk ;
Slagmolen, Pieter ;
Maes, Frederik ;
Vandermeulen, Dirk ;
Suetens, Paul .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) :19-29
[8]   PET-CT image registration in the chest using free-form deformations [J].
Mattes, D ;
Haynor, DR ;
Vesselle, H ;
Lewellen, TK ;
Eubank, W .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (01) :120-128
[9]  
MODAT M, 2009, COMPUT METH IN PRESS
[10]   Nonrigid registration using free-form deformations: Application to breast MR images [J].
Rueckert, D ;
Sonoda, LI ;
Hayes, C ;
Hill, DLG ;
Leach, MO ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (08) :712-721