Performance analysis of a novel augmented desalination and cooling system using modified vapor compression refrigeration integrated with humidification-dehumidification desalination

被引:36
作者
Anand, B. [1 ]
Murugavelh, S. [1 ]
机构
[1] Vellore Inst Technol, CO2 Res & Green Technol Ctr, Vellore, Tamil Nadu, India
关键词
Desalination; Cooling; Vapor compression refrigeration; Urban heat island mitigation; Humidification-dehumidification; COMBINED 2-STAGE DESALINATION; HEAT-PUMP; EXERGY ANALYSIS; ENERGY; WATER; CONSUMPTION; RECOVERY; ISLAND; CITY;
D O I
10.1016/j.jclepro.2020.120224
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Waste heat rejection to ambient from air conditioning systems is one of the major causes of urban heat island effect. Increased urbanization and living standards leads to increased water demand. In this work, a new design of vapor compression refrigeration system integrated with humidification-dehumidification desalination is proposed without changing the actual size of vapor compression refrigeration system. The present system consists of a compressor, an evaporative condenser, an expansion device, an evaporator and a suction fan. Water to be desalinated is sprayed over the evaporative condenser. The evaporative condenser and the evaporator are also acting as humidifier and dehumidifier of humidification-dehumidification desalination. In order to recover waste heat rejected to ambient, cooling of evaporative condenser using indoor air and subsequent condensation of hot humid air in evaporator is proposed in this work. The proposed system performance such as desalination yield, cooling output, coefficient of performance, gained output ratio, energy utilization factor are analysed for various ambient temperature and relative humidity. The maximum desalination yield and cooling output are 7.35 LPH and 1.89 kW respectively. The highest system coefficient of performance, gained output ratio and energy utilization factor are 2.16, 6.11 and 8.27 respectively at ambient temperature of 20 degrees C and 30% RH. The annual average desalination and cooling output are 25.884 m(3)/year and 4.26 MWh/year respectively. The exergy efficiency of the proposed system is 39.34%. The unit cost of desalination is estimated to be $0.0096/L. (C) 2020 Published by Elsevier Ltd.
引用
收藏
页数:13
相关论文
共 40 条
[1]   A review on exergy analysis of vapor compression refrigeration system [J].
Ahamed, J. U. ;
Saidur, R. ;
Masjuki, H. H. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1593-1600
[2]   Air-conditioning condensate recovery and applications-Current developments and challenges ahead [J].
Algarni, Salem ;
Saleel, C. A. ;
Mujeebu, M. Abdul .
SUSTAINABLE CITIES AND SOCIETY, 2018, 37 :263-274
[3]   Analysis of solar desalination system using heat pump [J].
Amin, Zakaria Mohd ;
Hawlader, M. N. A. .
RENEWABLE ENERGY, 2015, 74 :116-123
[4]   A hybrid system for power, desalination, and cooling using concentrated photovoltaic/thermal collector [J].
Anand, B. ;
Murugavelh, S. .
ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (01) :1416-1436
[5]   Performance analysis of combined two stage desalination and cooling plant with different solar collectors [J].
Anand, B. ;
Shankar, R. ;
Srinivas, T. ;
Murugavelh, S. .
DESALINATION AND WATER TREATMENT, 2019, 156 :136-147
[6]  
Bahman A., 2014, INT REFR AIR COND C
[7]  
Bejan A., 2016, ADV ENG THERMODYNAMI, DOI [10.1002/9781119245964.ch5, DOI 10.1002/9781119245964.CH5]
[8]   Thermal Performance Simulation of a Heat Pump Assisted Solar Desalination System for Kazakhstan Climatic Conditions [J].
Belyayev, Yerzhan ;
Mohanraj, Murugesan ;
Jayaraj, Simon ;
Kaltayev, Aidarkhan .
HEAT TRANSFER ENGINEERING, 2019, 40 (12) :1060-1072
[9]   Hot Water Making Potential Using of a Conventional Air-Conditioner as an Air-Water Heat Pump [J].
Chaiwongsa, Praitoon ;
Duangthongsuk, Weerapun .
2ND INTERNATIONAL SCIENCE, SOCIAL SCIENCE, ENGINEERING AND ENERGY CONFERENCE 2010 (I-SEEC 2010), 2011, 8 :165-170
[10]   Augmented desalination with cooling integration [J].
Chiranjeevi, C. ;
Srinivas, T. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 80 :106-119