Three dimensional volume quantification of aortic valve calcification using multislice computed tomography

被引:62
作者
Morgan-Hughes, GJ [1 ]
Owens, PE [1 ]
Roobottom, CA [1 ]
Marshall, AJ [1 ]
机构
[1] Plymouth NHS Trust, Plymouth PL6 8DH, Devon, England
关键词
D O I
10.1136/heart.89.10.1191
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To assess a new multislice computed tomography (CT) technique for three dimensional quantification of aortic valve calcification volume (3D AVCV) and to study the relation between stenosis and calcification of the aortic valve. Methods: 50 patients with echocardiographic calcification of the aortic valve underwent two separate ECG triggered multislice CT for quantification of 3D AVCV. The agreement between the two 3D AVCV scores was assessed and 3D AVCV was compared with echocardiographic markers of severity of aortic stenosis. Results: Overall the level of agreement between the two 3D AVCV scores was excellent (median interscan variability 7.9% (interquartile range 10.1); correlation coefficient, r=0.99; repeatability coefficient 237.8 mm3 (limits of agreement -393 to 559 mm(3))). However, the magnitude of the 3D AVCV did influence the interscan variability. The 3D AVCV correlated closely with the maximal predicted transvalvar gradient (r(2)=0.77) and aortic valve area (r(2)=0.73). Conclusions: Multislice CT provides a technique for quantifying 3D AVCV that has good reproducibility. There is a close non-linear relation between echocardiographic parameters of severity of valve stenosis and 3D AVCV scores.
引用
收藏
页码:1191 / 1194
页数:4
相关论文
共 21 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[3]   Association of cholesterol levels, hydroxymethylglutaryl coenzyme-A reductase inhibitor treatment, and progression of aortic stenosis in the community [J].
Bellamy, MF ;
Pellikka, PA ;
Klarich, KW ;
Tajik, AJ ;
Enriquez-Sarano, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (10) :1723-1730
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Reproducibility of electron-beam CT measures of aortic valve calcification [J].
Budoff, MJ ;
Mao, SS ;
Takasu, J ;
Shavelle, DM ;
Zhao, XQ ;
O'Brien, KD .
ACADEMIC RADIOLOGY, 2002, 9 (10) :1122-1127
[6]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[7]   Correlation of degree of aortic valve stenosis by Doppler echocardiogram to quantity of calcium in the valve by electron beam tomography [J].
Kaden, JJ ;
Freyer, S ;
Weisser, G ;
Willingstorger, W ;
Bilbal, A ;
Pfleger, S ;
Süselbeck, T ;
Haase, KK ;
Dempfle, CE ;
Borggrefe, M .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (05) :554-+
[8]  
Kizer JR, 2001, J HEART VALVE DIS, V10, P361
[9]   Determination of coronary calcium with Multi-slice Spiral computed tomography: a comparative study with electron-beam CT [J].
Knez, A ;
Becker, C ;
Becker, A ;
Leber, A ;
White, C ;
Reiser, M ;
Steinbeck, G .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (04) :295-303
[10]   Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT [J].
Kopp, AF ;
Ohnesorge, B ;
Becker, C ;
Schröder, S ;
Heuschmid, M ;
Küttner, A ;
Kuzo, R ;
Claussen, CD .
RADIOLOGY, 2002, 225 (01) :113-119