Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice

被引:10
作者
Nezafat, Maryam [1 ,2 ,3 ]
Ramos, Isabel T. [1 ]
Henningsson, Markus [1 ]
Pratti, Andrea [1 ]
Basha, Tamer [4 ]
Botnar, Rene M. [1 ,5 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
[2] Beth Israel Deaconess Med Ctr, Dept Med, Boston, MA 02215 USA
[3] Harvard Med Sch, Boston, MA 02115 USA
[4] Cairo Univ, Biomed Engn Dept, Giza, Egypt
[5] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
来源
PLOS ONE | 2017年 / 12卷 / 11期
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
ACUTE MYOCARDIAL-INFARCTION; LATE GADOLINIUM ENHANCEMENT; MOUSE MYOCARDIUM; MOLLI; MRI; QUANTIFICATION; HEART; T1; OPTIMIZATION; SASHA;
D O I
10.1371/journal.pone.0187621
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Object To develop and evaluate a 2D modified Look-Locker (MOLLI) for high-resolution T-1 mapping in mice using a 3T MRI scanner. Materials and methods To allow high-resolution T-1 mapping in mice at high heart rates a multi-shot ECG-triggered 2D MOLLI sequence was developed. In the proposed T-1 mapping sequence the optimal number of sampling points and pause cardiac cycles following an initial adiabatic inversion pulse was investigated in a phantom. Seven native control and eight mice, 3 days post myocardial infarction (MI) after administration of gadolinium were scanned. Two experienced readers graded the visual T-1 map quality. Results In T-1 phantoms, there were no significant differences (<0.4% error) between 12, 15 and 20 pause cardiac cycles (p = 0.1, 0.2 and 0.6 respectively) for 8 acquisition cardiac cycles for 600bpm in comparison to the conventional inversion recovery spin echo T-1 mapping sequence for short T-1's (< 600 ms). Subsequently, all in-vivo scans were performed with 8 data acquisitions and 12 pause cardiac cycles to minimize scan time. The mean native T-1 value of myocardium in control animal was 820.5 +/- 52 ms. The post-contrast T-1 measured 3 days after MI in scar was 264 +/- 59 ms and in healthy myocardium was 512 +/- 62 ms. The Bland-Altman analysis revealed mean difference of only -1.06% of infarct size percentage between T-1 maps and LGE. Conclusions A multi-shot 2D MOLLI sequence has been presented that allows reliable measurement of high spatial resolution T-1 maps in mice for heart rates up to 600bpm.
引用
收藏
页数:13
相关论文
共 24 条
  • [1] Advanced methods for quantification of infarct size in mice using three-dimensional high-field late gadolinium enhancement MRI
    Bohl, Steffen
    Lygate, Craig A.
    Barnes, Hannah
    Medway, Debra
    Stork, Lee-Anne
    Schulz-Menger, Jeanette
    Neubauer, Stefan
    Schneider, Jurgen E.
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2009, 296 (04): : H1200 - H1208
  • [2] Three-dimensional T1 mapping of the mouse heart using variable flip angle steady-state MR imaging
    Coolen, Bram F.
    Geelen, Tessa
    Paulis, Leonie E. M.
    Nauerth, Arno
    Nicolay, Klaas
    Strijkers, Gustav J.
    [J]. NMR IN BIOMEDICINE, 2011, 24 (02) : 154 - 162
  • [3] MR in mouse models of cardiac disease
    Epstein, Frederick H.
    [J]. NMR IN BIOMEDICINE, 2007, 20 (03) : 238 - 255
  • [4] Optimization of the ultrafast Look-Locker echo-planar imaging T1 mapping sequence
    Freeman, AJ
    Gowland, PA
    Mansfield, P
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (07) : 765 - 772
  • [5] SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING
    HAASE, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) : 77 - 89
  • [6] Rapid multislice T1 mapping of mouse myocardium: Application to quantification of manganese uptake in -Dystrobrevin knockout mice
    Jiang, Kai
    Li, Wen
    Li, Wei
    Jiao, Sen
    Castel, Laurie
    Van Wagoner, David R.
    Yu, Xin
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) : 1370 - 1379
  • [7] Adiabatic Inversion Pulses for Myocardial T1 Mapping
    Kellman, Peter
    Herzka, Daniel A.
    Hansen, Michael Schacht
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1428 - 1434
  • [8] Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI method
    Kellman, Peter
    Herzka, Daniel A.
    Arai, Andrew E.
    Hansen, Michael Schacht
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [9] Rapid T1 Mapping of Mouse Myocardium With Saturation Recovery Look-Locker Method
    Li, Wen
    Griswold, Mark
    Yu, Xin
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (05) : 1296 - 1303
  • [10] Detection and quantification of magnetically labeled cells by cellular MRI
    Liu, Wei
    Frank, Joseph A.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (02) : 258 - 264