Influence of ground granulated blast furnace slag on early-age cracking potential of internally cured high performance concrete

被引:59
作者
Shen, Dejian [1 ]
Jiao, Yang [1 ]
Kang, Jiacheng [1 ]
Feng, Zhizhuo [1 ]
Shen, Yongqiang [1 ]
机构
[1] Hohai Univ, Coll Civil & Transportat Engn, 1 Xikang Rd, Nanjing 210098, Peoples R China
基金
中国国家自然科学基金;
关键词
High performance concrete; Ground granulated blast furnace slag; Stress rate; Internal curing; Early age; Cracking potential parameter; Super absorbent polymer; SUPER ABSORBENT POLYMERS; HIGH-STRENGTH CONCRETE; RESTRAINED SHRINKAGE CRACKING; RESIDUAL-STRESS DEVELOPMENT; FIBER-REINFORCED CONCRETE; CEMENT-BASED MATERIALS; TENSILE CREEP; MECHANICAL-PROPERTIES; AUTOGENOUS SHRINKAGE; DRYING SHRINKAGE;
D O I
10.1016/j.conbuildmat.2019.117083
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High performance concrete (HPC) with low water-to-binder (w/b) ratio has been used widely in the actual project. However, high autogenous shrinkage induced by the low w/b ratio would cause the residual tensile stress in HPC when the shrinkage is restrained. The cracking may occur in HPC if the residual tensile stress exceeds the developing tensile strength. Ground granulated blast furnace slag (GGBFS) has been used widely in the mixture of HPC as a kind of mineral admixture. The influence of GGBFS on the cracking potential of concrete has been studied. However, investigations on the influence of GGBFS on the early-age cracking potential of internally cured high performance concrete (ICC) with super absorbent polymers (SAPs) as an internal curing (IC) agent by using the ring test are still lacking. Investigations on the early-age cracking potential of ICC with different GGBFS contents (0%, 20%, 35%, and 50%) by using the ring test were conducted in the present study. Results and corresponding analysis showed that: (1) the free shrinkage strain, residual tensile stress, stress relaxation, cracking potential parameter, and stress rate of ICC with SAPs decreased with the increase of GGBFS content; (2) the early-age cracking potential of ICC with SAPs based on the cracking potential parameter and stress rate decreased with the increase of GGBFS content. The results in the present study could be used to evaluate the influence of GGBFS on the early-age cracking potential of ICC with SAPs. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 80 条
  • [1] Aashto S., 1996, AASHTO Designation, P34
  • [2] Early age shrinkage cracking of restrained metakaolin-slag-palm oil fuel ash binder geopolymer mortars
    Aboshia, Ali Mohamed Ali
    Rahmat, Riza Atiq
    Zain, Muhammad Fauzi Mohd
    Ismail, Amiruddin
    [J]. JOURNAL OF SUSTAINABLE CEMENT-BASED MATERIALS, 2018, 7 (05) : 271 - 295
  • [3] Altoubat SA, 2001, ACI MATER J, V98, P323
  • [4] Restrained shrinkage behavior of Self-Compacting Concrete containing ground-granulated blast-furnace slag
    Altoubat, Salah
    Badran, Deena
    Junaid, M. Talha
    Leblouba, Moussa
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 129 : 98 - 105
  • [5] Shrinkage cracking properties of slag concretes with one-day curing
    Aly, T.
    Sanjayan, J. G.
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2008, 60 (01) : 41 - 48
  • [6] [Anonymous], 2013, THESIS
  • [7] [Anonymous], 2018, CL581C1581M18A ASTM
  • [8] [Anonymous], 2000, 1235023 BS EN
  • [9] Wet and dry cured compressive strength of concrete containing ground granulated blast-furnace slag
    Atis, Cengiz Duran
    Bilim, Cahit
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (08) : 3060 - 3065
  • [10] Barrett T. J., 2012, Proceedings of the 2012 Structures Congress. Structures Congress 2012, P699, DOI 10.1061/9780784412367.063