Electrocatalytic determination of Reduced Glutathione using rutin as a mediator at acetylene black spiked carbon paste electrode

被引:41
作者
Huang, Ying [1 ]
Yan, Huijie [1 ]
Tong, Yuejin [1 ]
机构
[1] Fujian Normal Univ, Coll Chem & Chem Engn, Fuzhou 350007, Fujian, Peoples R China
关键词
Glutathione; Rutin; Acetylene black; Electrocatalytic oxidation; HEMOLYZED ERYTHROCYTE; THIOLS; CYSTEINE; CYSTEINYLGLYCINE; ELECTROPHORESIS; HOMOCYSTEINE; DISULFIDES; LIQUID; PLASMA; SENSOR;
D O I
10.1016/j.jelechem.2014.12.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrocatalytic oxidation of glutathione based on rutin,as a mediator was studied at acetylene black (AB) modified carbon paste electrode (CPE). The results of cyclic voltammetric experiments showed that rutin could catalyze oxidation of GSH in PBS (pH 7.0) and the oxidation current was greatly increased by using AB-CPE compared to the nonmodified CPE. The kinetic parameters such as catalytic rate constant and diffusion coefficient were obtained using double potential step chronoamperometry. Under the optimum conditions, the electrocatalytic oxidation peak current was linear to the glutatbione concentration range from 0.5 mu M to 3.5 mu M and 2.5 mu M to 25 mu M with the detection limit of 0.080 mu M (S/N = 3) by differential normal pulse voltammetry (DNPV). The proposed method has been applied to the determination of glutathione in pharmaceutical sample with satisfactory results. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 34 条
[1]   Electroanalytical exploitation of nitroso phenyl modified carbon-thiol interactions: Application to the low voltage determination of thiols [J].
Abiman, Poobalasingam ;
Wildgoose, Gregory G. ;
Compton, Richard G. .
ELECTROANALYSIS, 2007, 19 (04) :437-444
[2]   THE USE OF H-1 SPIN-ECHO NMR AND HPLC TO CONFIRM DOXORUBICIN INDUCED DEPLETION OF GLUTATHIONE IN THE INTACT HELA-CELL [J].
ALKABBAN, M ;
WATSON, ID ;
STEWART, MJ ;
REGLINSKI, J ;
SMITH, WE ;
SUCKLING, CJ .
BRITISH JOURNAL OF CANCER, 1988, 57 (06) :553-558
[3]  
BARD A.J., 1982, ELECTROCHEMICAL METH
[4]   Blood oxidative stress in amyotrophic lateral sclerosis [J].
Bonnefont-Rousselot, D ;
Lacomblez, L ;
Jaudon, MC ;
Lepage, S ;
Salachas, F ;
Bensimon, G ;
Bizard, C ;
Doppler, V ;
Delattre, J ;
Meininger, V .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2000, 178 (01) :57-62
[5]   Determination of glutathione in hemolysed erythrocyte with amperometric sensor based on TTF-TCNQ [J].
Calvo-Marzal, Percy ;
Chumbimuni-Torres, Karin Y. ;
Hoehr, Nelci Fenalti ;
Kubota, Lauro T. .
CLINICA CHIMICA ACTA, 2006, 371 (1-2) :152-158
[6]   The antioxidant glutathione peroxidase family and spermatozoa: A complex story [J].
Drevet, Joel R. .
MOLECULAR AND CELLULAR ENDOCRINOLOGY, 2006, 250 (1-2) :70-79
[7]   Determination of glutathione in hemolysed erythrocyte by flow injection analysis with chemiluminescence detection [J].
Ensafi, A. A. ;
Khayamian, T. ;
Hasanpour, F. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (01) :140-144
[8]  
Galus Z., 1976, Fundamentals of Electrochemical Analysis
[9]   Fully automated method for simultaneous determination of total cysteine, cysteinylglycine, glutathione and homocysteine in plasma by HPLC with UV absorbance detection [J].
Glowacki, Rafal ;
Bald, Edward .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (28) :3400-3404
[10]   Analysis of glutathione in rat airway surface liquid by capillary zone electrophoresis with conductivity detection [J].
Govindaraju, K ;
Govindaraju, V ;
Eidelman, DH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02) :369-376