A multicenter randomized comparison of paclitaxel-coated balloon with plain balloon angioplasty in patients with small vessel disease

被引:57
作者
Funatsu, Atsushi [1 ,10 ]
Nakamura, Shigeru [1 ]
Inoue, Naoto [2 ]
Nanto, Shinsuke [3 ]
Nakamura, Masato [4 ]
Iwabuchi, Masashi [5 ]
Ando, Kenji [5 ]
Asano, Ryuta [6 ]
Habara, Seiji [7 ]
Saito, Shigeru [8 ]
Kozuma, Ken [9 ]
Mitsudo, Kazuaki [7 ]
机构
[1] Kyoto Katsura Hosp, Kyoto, Japan
[2] Sendai Kousei Hosp, Sendai, Miyagi, Japan
[3] Osaka Univ, Grad Sch Med, Osaka, Japan
[4] Toho Univ, Ohashi Med Ctr, Tokyo, Japan
[5] Kokura Mem Hosp, Kitakyushu, Fukuoka, Japan
[6] Sakakibara Heart Inst, Tokyo, Japan
[7] Kurashiki Cent Hosp, Kurashiki, Okayama, Japan
[8] Shonan Kamakura Gen Hosp, Kamakura, Kanagawa, Japan
[9] Teikyo Univ Hosp, Tokyo, Japan
[10] 17 Yamada Hirao Cho,Nishikyo Ku, Kyoto 6158256, Japan
关键词
Paclitaxel-coated balloon; Small vessel disease; Native coronary artery; Balloon angioplasty; SMALL CORONARY-ARTERIES; DRUG-ELUTING BALLOON; LUMEN ENLARGEMENT; STENT RESTENOSIS; CATHETER; TRIAL; PLACEMENT; REGISTRY; LESIONS; BELLO;
D O I
10.1007/s00392-017-1126-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim We investigated the efficacy and safety of using paclitaxel-coated balloon (PCB) to treat small vessel disease. Methods and results In this multicenter, prospective, randomized controlled trial, one-hundred and thirty-five patients with native coronary lesions in small vessels were randomized into a PCB group and plain balloon angioplasty (POBA) group at a ratio of 2:1. There were no differences in target vessel failure (TVF) that was defined as cardiac death or target vessel-related myocardial infarction or target lesion revascularization (TLR), between the two groups (3.4 vs. 10.3%; P = 0.20), and TLR was slightly lower in the PCB group (2.3%) than that in the POBA group (10.3%) during 24 weeks follow-up. The late lumen loss (LLL) was significantly lower in the PCB group (0.01 +/- 0.31 vs. 0.32 +/- 0.34 mm; P < 0.01) and late lumen enlargement (LLE) was more frequently observed in the PCB group (48 vs. 15%; P < 0.01) by angiographic follow-up after 24 weeks. There were no cases of death, myocardial infarction, thrombosis and reocclusion in either group. Conclusions This study was not able to demonstrate superiority of PCB compared with POBA.
引用
收藏
页码:824 / 832
页数:9
相关论文
共 24 条
[1]   Effect of Drug-Coated Balloons in Native Coronary Artery Disease Left With a Dissection [J].
Cortese, Bernardo ;
Orrego, Pedro Silva ;
Agostoni, Pierfrancesco ;
Buccheri, Dario ;
Piraino, Davide ;
Andolina, Giuseppe ;
Seregni, Romano Giuseppe .
JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (15) :2003-2009
[2]   Stent placement to prevent restenosis after angioplasty in small coronary arteries [J].
Doucet, S ;
Schalij, MJ ;
Vrolix, MCM ;
Hilton, D ;
Chenu, P ;
de Bruyne, B ;
Udayachalerm, W ;
Seth, A ;
Bilodeau, L ;
Reiber, JHC ;
Harel, F ;
Lespérance, J .
CIRCULATION, 2001, 104 (17) :2029-2033
[3]   One-Year Outcome of Small-Vessel Disease Treated with Sirolimus-Eluting Stents: A Subgroup Analysis of the e-SELECT Registry [J].
Gao, Runlin ;
Abizaid, Alexandre ;
Banning, Adrian ;
Bartorelli, Antonio L. ;
Zavik, Vladimird ;
Ellis, Stephen ;
Jeong, Myung Ho ;
Legrand, Victor ;
Spaulding, Christian ;
Urban, Philip .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2013, 26 (02) :163-172
[4]   A multicenter randomized comparison of paclitaxel-coated balloon catheter with conventional balloon angioplasty in patients with bare-metal stent restenosis and drug-eluting stent restenosis [J].
Habara, Seiji ;
Iwabuchi, Masashi ;
Inoue, Naoto ;
Nakamura, Shigeru ;
Asano, Ryuta ;
Nanto, Shinsuke ;
Hayashi, Yasuhiko ;
Shiode, Nobuo ;
Saito, Shigeru ;
Ikari, Yuji ;
Kimura, Takeshi ;
Hosokawa, Joji ;
Nakamura, Masato ;
Kotani, Jun-ichi ;
Kozuma, Ken ;
Mitsudo, Kazuaki .
AMERICAN HEART JOURNAL, 2013, 166 (03) :527-+
[5]   Effectiveness of Paclitaxel-Eluting Balloon Catheter in Patients With Sirolimus-Eluting Stent Restenosis [J].
Habara, Seiji ;
Mitsudo, Kazuaki ;
Kadota, Kazushige ;
Goto, Tsuyoshi ;
Fujii, Satoki ;
Yamamoto, Hiroyuki ;
Katoh, Harumi ;
Oka, Naoki ;
Fuku, Yasushi ;
Hosogi, Shingo ;
Hirono, Akitoshi ;
Maruo, Takeshi ;
Tanaka, Hiroyuki ;
Shigemoto, Yoshikazu ;
Hasegawa, Daiji ;
Tasaka, Hiroshi ;
Kusunose, Mana ;
Otsuru, Suguru ;
Okamoto, Yoji ;
Saito, Naoki ;
Tsujimoto, Yuki ;
Eguchi, Haruki ;
Miyake, Koshi ;
Yoshino, Mitsuru .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (02) :149-154
[6]   Performance of Everolimus-Eluting versus Paclitaxel-Eluting Coronary Stents in Small Vessels: Results from the SPIRIT III and SPIRIT IV Clinical Trials [J].
Ito, Hiroki ;
Hermiller, James B. ;
Yaqub, Manejeh ;
Newman, William ;
Sood, Poornima ;
Wang, John C. ;
Cannon, Louis ;
Maddux, James E. ;
Sudhir, Krishnankutty ;
Stone, Gregg W. .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2011, 24 (06) :505-513
[7]  
Kastrati A, 2000, CIRCULATION, V102, P2593
[8]   Local paclitaxel induces late lumen enlargement in coronary arteries after balloon angioplasty [J].
Kleber, Franz X. ;
Schulz, Antonia ;
Waliszewski, Matthias ;
Hauschild, Telse ;
Boehm, Michael ;
Dietz, Ulrich ;
Cremers, Bodo ;
Scheller, Bruno ;
Clever, Yvonne P. .
CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (03) :217-225
[9]   Drug-coated balloons for treatment of coronary artery disease: updated recommendations from a consensus group [J].
Kleber, Franz X. ;
Rittger, Harald ;
Bonaventura, Klaus ;
Zeymer, Uwe ;
Woehrle, Jochen ;
Jeger, Raban ;
Levenson, Benny ;
Moebius-Winkler, Sven ;
Bruch, Leonhard ;
Fischer, Dieter ;
Hengstenberg, Christian ;
Poerner, Tudor ;
Mathey, Detlef ;
Scheller, Bruno .
CLINICAL RESEARCH IN CARDIOLOGY, 2013, 102 (11) :785-797
[10]   Stent placement compared with balloon angioplasty for small coronary arteries -: In-hospital and 6-month clinical and angiographic results [J].
Koning, R ;
Eltchaninoff, H ;
Commeau, P ;
Khalife, K ;
Gilard, M ;
Lipiecki, J ;
Coste, P ;
Bedossa, M ;
Lefèvre, T ;
Brunel, P ;
Morice, MC ;
Maillard, L ;
Guyon, P ;
Puel, J ;
Cribier, A .
CIRCULATION, 2001, 104 (14) :1604-1608