Alveolar pressure monitoring:: an evaluation in a lung model and in patients with acute lung injury

被引:20
作者
Sondergaard, S [1 ]
Kárason, S
Wiklund, J
Lundin, S
Stenqvist, O
机构
[1] Sahlgrens Univ Hosp, Dept Anaesthesia & Intens Care, Gothenburg, Sweden
[2] Landspitali Univ Hosp, Dept Anaesthesia & Intens Care, Reykjavik, Iceland
[3] Sahlgrens Univ Hosp, Dept Biomed Engn, Gothenburg, Sweden
关键词
respiratory mechanics; alveolar pressure; dynostatic algorithm;
D O I
10.1007/s00134-003-1730-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives We evaluated an algorithm for continuous on-line monitoring of alveolar pressure over time in a lung model with lower and upper inflection points and variable resistance ratios and in patients with acute lung injury. The algorithm is based on "static" pressure/volume curves obtained from tracheal pressure measurements under dynamic conditions. Design and setting: Experimental and clinical evaluation of algorithm in a university hospital laboratory and intensive care unit. Patients: Ten patients undergoing postoperative respiratory therapy (feasibility of tracheal measurement) and ten patients with acute lung injury undergoing ventilator treatment (evaluation of algorithm). Measurements and results: Direct tracheal pressure measurements with a catheter inserted through the endotracheal tube. Comparison of measured alveolar and the dynostatic alveolar pressure vs. time in a lung model with changes in five ventilatory parameters. Examples of clinical monitoring are reported. In the model there was excellent agreement between alveolar pressures obtained by the algorithm, the dynostatic alveolar pressure, and measured alveolar pressure at all ventilator settings. For inspiratory/expiratory resistance ratios between 1:2.1-2.1:1, the dynostatic alveolar pressure was within +/-1.5 cm H2O of measured alveolar pressure. In patients the technique for direct tracheal pressure measurement using a catheter inserted through the endotracheal tube functioned satisfactorily with intermittent air flushes for cleansing. Conclusions: Using a thin tracheal pressure catheter inserted through the endotracheal tube alveolar pressure allows continuous bedside monitoring with ease and precision using the dynostatic algorithm. The method is unaffected by tube and connector geometry or by secretions.
引用
收藏
页码:955 / 962
页数:8
相关论文
共 38 条
[1]   LUNG, CHEST-WALL, AND TOTAL RESPIRATORY SYSTEM RESISTANCES AND ELASTANCES IN THE NORMAL RANGE OF BREATHING [J].
BARNAS, GM ;
CAMPBELL, DN ;
MACKENZIE, CF ;
MENDHAM, JE ;
FAHY, BG ;
RUNCIE, CJ ;
MENDHAM, GE .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (01) :110-113
[2]   DEPENDENCIES OF RESPIRATORY SYSTEM RESISTANCE AND ELASTANCE ON AMPLITUDE AND FREQUENCY IN THE NORMAL RANGE OF BREATHING [J].
BARNAS, GM ;
MILLS, PJ ;
MACKENZIE, CF ;
ASHBY, M ;
SEXTON, WL ;
IMLE, PC ;
WILSON, PD .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (02) :240-244
[3]   COMPARISON OF SOME METHODS FOR MEASURING TOTAL RESPIRATORY RESISTANCE [J].
BERGMAN, NA ;
WALTEMATH, CL .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 36 (01) :131-134
[4]  
BERTSCHMANN V, 1990, INTENSIVMED, V27, P42
[5]   Respiratory mechanics in patients ventilated for critical lung disease [J].
Beydon, L ;
Svantesson, C ;
Brauer, K ;
Lemaire, F ;
Jonson, B .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (02) :262-273
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Tidal volume reduction for prevention of ventilator-induced lung injury in acute respiratory distress syndrome [J].
Brochard, L ;
Roudot-Thoraval, F ;
Roupie, E ;
Delclaux, C ;
Chastre, J ;
Fernandez-Mondéjar, E ;
Clémenti, E ;
Mancebo, J ;
Factor, P ;
Matamis, D ;
Ranieri, M ;
Blanch, L ;
Rodi, G ;
Mentec, H ;
Dreyfuss, D ;
Ferrer, M ;
Brun-Buisson, C ;
Tobin, M ;
Lemaire, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (06) :1831-1838
[8]  
Brochard L., 1998, PRINCIPLES PRACTICE, P597
[9]   Prospective, randomized, controlled clinical trial comparing traditional versus reduced tidal volume ventilation in acute respiratory distress syndrome patients [J].
Brower, RG ;
Shanholtz, CB ;
Fessler, HE ;
Shade, DM ;
White, P ;
Wiener, CM ;
Teeter, JG ;
Dodd-o, JM ;
Almog, Y ;
Piantadosi, S .
CRITICAL CARE MEDICINE, 1999, 27 (08) :1492-1498
[10]   Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. [J].
Brower, RG ;
Matthay, MA ;
Morris, A ;
Schoenfeld, D ;
Thompson, BT ;
Wheeler, A ;
Wiedemann, HP ;
Arroliga, AC ;
Fisher, CJ ;
Komara, JJ ;
Perez-Trepichio, P ;
Parsons, PE ;
Wolkin, R ;
Welsh, C ;
Fulkerson, WJ ;
MacIntyre, N ;
Mallatratt, L ;
Sebastian, M ;
McConnell, R ;
Wilcox, C ;
Govert, J ;
Thompson, D ;
Clemmer, T ;
Davis, R ;
Orme, J ;
Weaver, L ;
Grissom, C ;
Eskelson, M ;
Young, M ;
Gooder, V ;
McBride, K ;
Lawton, C ;
d'Hulst, J ;
Peerless, JR ;
Smith, C ;
Brownlee, J ;
Pluss, W ;
Kallet, R ;
Luce, JM ;
Gottlieb, J ;
Elmer, M ;
Girod, A ;
Park, P ;
Daniel, B ;
Gropper, M ;
Abraham, E ;
Piedalue, F ;
Glodowski, J ;
Lockrem, J ;
McIntyre, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) :1301-1308