A Comparison of Monopolar and Bipolar EEG Recordings for SSVEP Detection

被引:20
作者
Diez, Pablo F.
Mut, Vicente
Laciar, Eric
Avila, Enrique
机构
来源
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2010年
关键词
D O I
10.1109/IEMBS.2010.5627451
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a comparative study over the detection of Steady-State Visual Evoked Potential (SSVEP) with monopolar or bipolar electroencephalographic (EEG) recordings in a Brain-Computer Interface experiment. Five subjects participated in this study. They were stimulated with four flickering lights at 13, 14, 15 and 16 Hz and the EEG was measured simultaneously with two bipolar channels (O-1-P-3 and O-2-P-4) and with six monopolar channels at O-1, O-2, P-3, P-4, T-5 and T-6 referenced to F-Z. The EEG was processed by means of spectral analysis and the estimation of power at each stimulation frequency and its harmonics. In average, the monopolar recordings present accuracy in classification of 74.5% against an 80.1% for bipolar recordings. It was found that bipolar recording are better than monopolar recordings for detection of SSVEP.
引用
收藏
页码:5803 / 5806
页数:4
相关论文
共 10 条
[1]  
Allison B., IEEE T NEUR IN PRESS
[2]  
Cecotti H., 2010, IEEE T NEUR IN PRESS
[3]  
Fehmi L G, 1989, Int J Psychosom, V36, P23
[4]  
Friman O., 2007, IEEE T BIOMED ENG, V54
[5]  
Friman O., 2007, P 3 INT IEEE EMBS C
[6]  
Gao X, 2003, IEEE T NEURAL SYST R, V11
[7]  
Lin Z., 2006, IEEE T BIOMED ENG, V53
[8]  
Maggi L., 2006, P 28 IEEE EMBS ANN I
[9]   Control of an electrical prosthesis with an SSVEP-based BCI [J].
Mueller-Putz, Gernot R. ;
Pfurtscheller, Gert .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (01) :361-364
[10]   Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives [J].
Vialatte, Francois-Benoit ;
Maurice, Monique ;
Dauwels, Justin ;
Cichocki, Andrzej .
PROGRESS IN NEUROBIOLOGY, 2010, 90 (04) :418-438