Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies

被引:2
作者
Liu, Wenlei [1 ]
Rong, Junyan [1 ]
Gao, Peng [1 ]
Liao, Qimei [1 ]
Lu, HongBing [1 ]
机构
[1] Fourth Mil Med Univ, Dept Biomed Engn, Xian 710032, Shaanxi, Peoples R China
来源
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING | 2016年 / 9783卷
关键词
Scatter; Beam hardening; low-dose CT; cone-beam CT; Sparse-view; ART; CS; COMPUTED-TOMOGRAPHY; GENERAL FRAMEWORK; RECONSTRUCTION;
D O I
10.1117/12.2217424
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray scatter poses a significant limitation to image quality in cone-beam CT (CBCT), as well as beam hardening, resulting in image artifacts, contrast reduction, and lack of CT number accuracy. Meanwhile the x-ray radiation dose is also non-ignorable. Considerable scatter or beam hardening correction methods have been developed, independently, and rarely combined with low-dose CT reconstruction. In this paper, we combine scatter suppression with beam hardening correction for sparse-view CT reconstruction to improve CT image quality and reduce CT radiation. Firstly, scatter was measured, estimated, and removed using measurement-based methods, assuming that signal in the lead blocker shadow is only attributable to x-ray scatter. Secondly, beam hardening was modeled by estimating an equivalent attenuation coefficient at the effective energy, which was integrated into the forward projector of the algebraic reconstruction technique (ART). Finally, the compressed sensing (CS) iterative reconstruction is carried out for sparse-view CT reconstruction to reduce the CT radiation. Preliminary Monte Carlo simulated experiments indicate that with only about 25% of conventional dose, our method reduces the magnitude of cupping artifact by a factor of 6.1, increases the contrast by a factor of 1.4 and the CNR by a factor of 15. The proposed method could provide good reconstructed image from a few view projections, with effective suppression of artifacts caused by scatter and beam hardening, as well as reducing the radiation dose. With this proposed framework and modeling, it may provide a new way for low-dose CT imaging.
引用
收藏
页数:8
相关论文
共 50 条
[41]   Local filtration based scatter correction for cone-beam CT using primary modulation [J].
Zhu, Lei .
MEDICAL PHYSICS, 2016, 43 (11) :6199-6209
[42]   Influence of Data Completion on Scatter Artifact Correction for Truncated Cone-Beam CT Data [J].
Waltrich, Nadine ;
Sawall, Stefan ;
Maier, Joscha ;
Kuntz, Jan ;
Stannigel, Kai ;
Lindenberg, Kai ;
Kachelriess, Marc .
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
[43]   Single-scan scatter correction for cone-beam CT using a stationary beam blocker: a preliminary study [J].
Niu, Tianye ;
Zhu, Lei .
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
[44]   X-ray scatter correction for dedicated cone beam breast CT using a forward-projection model [J].
Shi, Linxi ;
Vedantham, Srinivasan ;
Karellas, Andrew ;
Zhu, Lei .
MEDICAL PHYSICS, 2017, 44 (06) :2312-2320
[45]   Scatter correction for cone-beam computed tomography using moving blocker strips [J].
Wang, Jing ;
Mao, Weihua ;
Solberg, Timothy .
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
[46]   Physical phantom studies of helical cone-beam CT with exact reconstruction [J].
Tan, Jun ;
Li, H. Harold ;
Klein, Eric ;
Li, Hua ;
Parikh, Parag ;
Yang, Deshan .
MEDICAL PHYSICS, 2012, 39 (08) :4695-4704
[47]   Evaluation of an a priori scatter correction algorithm for cone-beam computed tomography based range and dose calculations in proton therapy [J].
Andersen, Andreas Gravgaard ;
Park, Yang-Kyun ;
Elstrom, Ulrik Vindelev ;
Petersen, Jorgen Breede Baltzer ;
Sharp, Gregory C. ;
Winey, Brian ;
Dong, Lei ;
Muren, Ludvig Paul .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 16 :89-94
[48]   Adaptive scatter kernel deconvolution modeling for cone-beam CT scatter correction via deep reinforcement learning [J].
Piao, Zun ;
Deng, Wenxin ;
Huang, Shuang ;
Lin, Guoqin ;
Qin, Peishan ;
Li, Xu ;
Wu, Wangjiang ;
Qi, Mengke ;
Zhou, Linghong ;
Li, Bin ;
Ma, Jianhui ;
Xu, Yuan .
MEDICAL PHYSICS, 2024, 51 (02) :1163-1177
[49]   MC SIMULATION FOR ESTIMATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kV X-RAY TUBE [J].
Miceli, A. ;
Thierry, R. ;
Flisch, A. ;
Sennhauser, U. ;
Casali, F. .
EUROPEAN NDT DAYS IN PRAGUE 2007: NDT IN PROGRESS, PROCEEDINGS, 2007, :111-120
[50]   Development of a beam stop array system with dual scan mode for scatter correction of cone-beam CT [J].
So Hyun Ahn ;
Jinho Choi ;
Kyu Chan Lee ;
Siyong Kim ;
Rena Lee .
Journal of the Korean Physical Society, 2014, 64 :1220-1229