Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies

被引:2
|
作者
Liu, Wenlei [1 ]
Rong, Junyan [1 ]
Gao, Peng [1 ]
Liao, Qimei [1 ]
Lu, HongBing [1 ]
机构
[1] Fourth Mil Med Univ, Dept Biomed Engn, Xian 710032, Shaanxi, Peoples R China
来源
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING | 2016年 / 9783卷
关键词
Scatter; Beam hardening; low-dose CT; cone-beam CT; Sparse-view; ART; CS; COMPUTED-TOMOGRAPHY; GENERAL FRAMEWORK; RECONSTRUCTION;
D O I
10.1117/12.2217424
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray scatter poses a significant limitation to image quality in cone-beam CT (CBCT), as well as beam hardening, resulting in image artifacts, contrast reduction, and lack of CT number accuracy. Meanwhile the x-ray radiation dose is also non-ignorable. Considerable scatter or beam hardening correction methods have been developed, independently, and rarely combined with low-dose CT reconstruction. In this paper, we combine scatter suppression with beam hardening correction for sparse-view CT reconstruction to improve CT image quality and reduce CT radiation. Firstly, scatter was measured, estimated, and removed using measurement-based methods, assuming that signal in the lead blocker shadow is only attributable to x-ray scatter. Secondly, beam hardening was modeled by estimating an equivalent attenuation coefficient at the effective energy, which was integrated into the forward projector of the algebraic reconstruction technique (ART). Finally, the compressed sensing (CS) iterative reconstruction is carried out for sparse-view CT reconstruction to reduce the CT radiation. Preliminary Monte Carlo simulated experiments indicate that with only about 25% of conventional dose, our method reduces the magnitude of cupping artifact by a factor of 6.1, increases the contrast by a factor of 1.4 and the CNR by a factor of 15. The proposed method could provide good reconstructed image from a few view projections, with effective suppression of artifacts caused by scatter and beam hardening, as well as reducing the radiation dose. With this proposed framework and modeling, it may provide a new way for low-dose CT imaging.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Low-dose and Scatter-free Cone-beam CT imaging: a preliminary study
    Dong, Xue
    Jia, Xun
    Niu, Tianye
    Zhu, Lei
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [22] Reduction in x-ray scatter and radiation dose for volume-of-interest (VOI) cone-beam breast CT-a phantom study
    Lai, Chao-Jen
    Chen, Lingyun
    Zhang, Huojun
    Liu, Xinming
    Zhong, Yuncheng
    Shen, Youtao
    Han, Tao
    Ge, Shuaiping
    Yi, Ying
    Wang, Tianpeng
    Yang, Wei T.
    Whitman, Gary J.
    Shaw, Chris C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21): : 6691 - 6709
  • [23] Comparison between beam-stop and beam-hole array scatter correction techniques for industrial X-ray cone-beam CT
    Schoerner, K.
    Goldammer, M.
    Stephan, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (03): : 292 - 299
  • [24] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [25] Overview of X-ray Scatter in Cone-beam Computed Tomography and Its Correction Methods
    Niu, Tianye
    Zhu, Lei
    CURRENT MEDICAL IMAGING REVIEWS, 2010, 6 (02) : 82 - 89
  • [26] Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner
    Kwan, ALC
    Boone, JM
    Shah, N
    MEDICAL PHYSICS, 2005, 32 (09) : 2967 - 2975
  • [27] Scatter Correction for Cone-Beam CT in Radiation Therapy
    Zhu, L.
    Xing, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [28] Library-Based X-Ray Scatter Correction for Dedicated Cone-Beam Breast CT: Clinical Validation
    Shi, L.
    Vedantham, S.
    Karellas, A.
    Zhu, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3819 - 3819
  • [29] Correction of veiling glare and scatter in cone-beam CT
    Baba, R
    Ueda, K
    Takagi, H
    RADIOLOGY, 1999, 213P : 453 - 453
  • [30] A Hybrid Scatter Correction Method for Cone-Beam CT
    Zhang, Feng
    Yan, Bin
    Li, Jianxin
    Li, Lei
    Jia, Pengxiang
    Hu, Guoen
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 23 - 27