Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies

被引:2
|
作者
Liu, Wenlei [1 ]
Rong, Junyan [1 ]
Gao, Peng [1 ]
Liao, Qimei [1 ]
Lu, HongBing [1 ]
机构
[1] Fourth Mil Med Univ, Dept Biomed Engn, Xian 710032, Shaanxi, Peoples R China
来源
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING | 2016年 / 9783卷
关键词
Scatter; Beam hardening; low-dose CT; cone-beam CT; Sparse-view; ART; CS; COMPUTED-TOMOGRAPHY; GENERAL FRAMEWORK; RECONSTRUCTION;
D O I
10.1117/12.2217424
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray scatter poses a significant limitation to image quality in cone-beam CT (CBCT), as well as beam hardening, resulting in image artifacts, contrast reduction, and lack of CT number accuracy. Meanwhile the x-ray radiation dose is also non-ignorable. Considerable scatter or beam hardening correction methods have been developed, independently, and rarely combined with low-dose CT reconstruction. In this paper, we combine scatter suppression with beam hardening correction for sparse-view CT reconstruction to improve CT image quality and reduce CT radiation. Firstly, scatter was measured, estimated, and removed using measurement-based methods, assuming that signal in the lead blocker shadow is only attributable to x-ray scatter. Secondly, beam hardening was modeled by estimating an equivalent attenuation coefficient at the effective energy, which was integrated into the forward projector of the algebraic reconstruction technique (ART). Finally, the compressed sensing (CS) iterative reconstruction is carried out for sparse-view CT reconstruction to reduce the CT radiation. Preliminary Monte Carlo simulated experiments indicate that with only about 25% of conventional dose, our method reduces the magnitude of cupping artifact by a factor of 6.1, increases the contrast by a factor of 1.4 and the CNR by a factor of 15. The proposed method could provide good reconstructed image from a few view projections, with effective suppression of artifacts caused by scatter and beam hardening, as well as reducing the radiation dose. With this proposed framework and modeling, it may provide a new way for low-dose CT imaging.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] A direct, empirical method for x-ray scatter correction in digital radiography and cone-beam CT
    Siewerdsen, J
    Bakhtiar, B
    Moseley, D
    Richard, S
    Keller, H
    Daly, M
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2092 - 2093
  • [12] Recent Development of Low-dose X-ray Cone-beam Computed Tomography
    Wang, Jing
    Liang, Zhengrong
    Lu, Hongbing
    Xing, Lei
    CURRENT MEDICAL IMAGING, 2010, 6 (02) : 72 - 81
  • [13] Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array
    Hattori, Haruki
    Yatagawa, Tatsuya
    Ohtake, Yutaka
    Suzuki, Hiromasa
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (03)
  • [14] A beam stop based correction procedure for high spatial frequency scatter in industrial cone-beam X-ray CT
    Peterzol, A.
    Letang, J. M.
    Babot, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (18): : 4042 - 4054
  • [15] X-ray Cone-Beam Breast Computed Tomography: phantom studies
    Russo, P.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4076 - 4083
  • [16] X-ray Cone-Beam Breast Computed Tomography: Phantom Studies
    Russo, Paolo
    Mettivier, Giovanni
    Lauria, Adele
    Montesi, Maria Cristina
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 160 - 172
  • [17] X-ray scatter suppression algorithm for cone beam volume CT
    Ning, RL
    Tang, XY
    Conover, DL
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 774 - 781
  • [18] Correction of scatter in megavoltage cone-beam CT
    Spies, L
    Ebert, M
    Groh, BA
    Hesse, BM
    Bortfeld, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03): : 821 - 833
  • [19] A new method for x-ray scatter correction:: first assessment on a cone-beam CT experimental setup
    Rinkel, J.
    Gerfault, L.
    Esteve, F.
    Dinten, J-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4633 - 4652
  • [20] A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT
    Siewerdsen, JH
    Daly, MJ
    Bakhtiar, B
    Moseley, DJ
    Richard, S
    Keller, H
    Jaffray, DA
    MEDICAL PHYSICS, 2006, 33 (01) : 187 - 197