Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies

被引:2
|
作者
Liu, Wenlei [1 ]
Rong, Junyan [1 ]
Gao, Peng [1 ]
Liao, Qimei [1 ]
Lu, HongBing [1 ]
机构
[1] Fourth Mil Med Univ, Dept Biomed Engn, Xian 710032, Shaanxi, Peoples R China
来源
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING | 2016年 / 9783卷
关键词
Scatter; Beam hardening; low-dose CT; cone-beam CT; Sparse-view; ART; CS; COMPUTED-TOMOGRAPHY; GENERAL FRAMEWORK; RECONSTRUCTION;
D O I
10.1117/12.2217424
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray scatter poses a significant limitation to image quality in cone-beam CT (CBCT), as well as beam hardening, resulting in image artifacts, contrast reduction, and lack of CT number accuracy. Meanwhile the x-ray radiation dose is also non-ignorable. Considerable scatter or beam hardening correction methods have been developed, independently, and rarely combined with low-dose CT reconstruction. In this paper, we combine scatter suppression with beam hardening correction for sparse-view CT reconstruction to improve CT image quality and reduce CT radiation. Firstly, scatter was measured, estimated, and removed using measurement-based methods, assuming that signal in the lead blocker shadow is only attributable to x-ray scatter. Secondly, beam hardening was modeled by estimating an equivalent attenuation coefficient at the effective energy, which was integrated into the forward projector of the algebraic reconstruction technique (ART). Finally, the compressed sensing (CS) iterative reconstruction is carried out for sparse-view CT reconstruction to reduce the CT radiation. Preliminary Monte Carlo simulated experiments indicate that with only about 25% of conventional dose, our method reduces the magnitude of cupping artifact by a factor of 6.1, increases the contrast by a factor of 1.4 and the CNR by a factor of 15. The proposed method could provide good reconstructed image from a few view projections, with effective suppression of artifacts caused by scatter and beam hardening, as well as reducing the radiation dose. With this proposed framework and modeling, it may provide a new way for low-dose CT imaging.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] X-ray scatter correction algorithm for 450 KeV cone-beam CT system
    Dept. of Engineering Physics, Tsinghua University, Beijing 100084, China
    Hedianzixue Yu Tance Jishue, 2006, 6 (908-911):
  • [2] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202
  • [3] EXPERIMENTAL SCATTER CORRECTION METHODS IN INDUSTRIAL X-RAY CONE-BEAM CT
    Schoerner, K.
    Goldammer, M.
    Stephan, J.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B, 2011, 1335 : 485 - 492
  • [4] Simulating low-dose cone-beam CT: a phantom study
    Ferrero, Andrea
    Fetterly, Ken
    Yu, Lifeng
    Schueler, Beth
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [5] Algorithm for X-ray Scatter, Beam-Hardening, and Beam Profile Correction in Diagnostic (Kilovoltage) and Treatment (Megavoltage) Cone Beam CT
    Maltz, Jonathan S.
    Gangadharan, Bijumon
    Bose, Supratik
    Hristov, Dimitre H.
    Faddegon, Bruce A.
    Paidi, Ajay
    Bani-Hashemi, Ali R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) : 1791 - 1810
  • [6] Low-Dose and Scatter-Free Cone-Beam CT Imaging Using a Stationary Beam Blocker in a Single Scan: Phantom Studies
    Dong, Xue
    Petrongolo, Michael
    Niu, Tianye
    Zhu, Lei
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [7] X-ray scatter correction for cone-beam CT using moving blocker array
    Zhu, L
    Strobel, N
    Fahrig, R
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 251 - 258
  • [8] Evaluation of scatter mitigation strategies for X-ray cone-beam CT
    Lasio, G.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2288 - 2289
  • [9] Simulation of x-ray images from the planning CT for online correction of scatter in cone-beam CT
    Rit, S.
    Romero, E.
    Oliva, M. Vila
    Brousmiche, S.
    Sarrut, D.
    Letang, J. M.
    Freud, N.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S115 - S115
  • [10] Improved scatter compensation method for low-dose cone-beam CT in SPECT/CT
    Wang, Jiong
    Wiegert, Jens
    Hansis, Eberhard
    Bredno, Joer
    Sowards-Emmerd, David
    Shao, Lingxiong
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53