A Novel Fault Detection and Fault Location Method for VSC-HVDC Links Based on Gap Frequency Spectrum Analysis

被引:8
|
作者
Yang, Qingqing [1 ]
Le Blond, Simon [2 ]
Cornelusse, Bertrand [3 ]
Vanderbemden, Philippe [3 ]
Li, Jianwei [3 ]
机构
[1] Beijing Elect Power Co State Grid, Beijing Elect Power Res Inst, Beijing, Peoples R China
[2] Univ Bath, Bath BA2 6ER, Avon, England
[3] Univ Liege, B-4000 Liege, Belgium
关键词
Fault current signal; fault detection; fault location transmission line; VSC-HVDC system; ENERGY-STORAGE SYSTEM; DESIGN;
D O I
10.1016/j.egypro.2017.12.625
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a one-end gap-based fault location method for VSC-HVDC transmission line using the fault current signal. Using the post-fault current time series, the frequency spectrum is generated for measuring the gaps between the contiguous peak frequencies. This method is able to locate the fault by analyzing the single-end fault current, which guarantees a faster response than using two-end data. The new gap-based approach is able to give accurate fault detection using any appropriate range of post fault signal. Furthermore, the proposed method is fault resistance independent. A two-terminal VSC-HVDC system is modeled in PSCAD/EMTDC. The algorithm is verified by studying different cases of different fault resistances in various fault locations. The result shows that the proposed method gives an accurate and reliable fault location detection along DC transmission line. In addition, the proposed algorithm can be potentially used in other HVDC systems. (C) 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the 9th International Conference on Applied Energy.
引用
收藏
页码:2243 / 2249
页数:7
相关论文
共 50 条
  • [1] Research on VSC-HVDC fault location method based on compressed sensing
    Yu, Hua'nan
    Ma, Congcong
    Wang, He
    Liu, Weilin
    Du, Yao
    Bai, Xiaofei
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (03): : 158 - 166
  • [2] A fault-location method for VSC-HVDC transmission lines based on natural frequency of current
    Song Guobing
    Chu Xu
    Cai Xinlei
    Gao Shuping
    Ran Mengbing
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 63 : 347 - 352
  • [3] Fault Location in VSC-HVDC Transmission Lines Based on WEMTR
    Zhang X.
    Tai N.
    Zheng X.
    Huang W.
    Sun K.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (03): : 589 - 598
  • [4] An intelligent algorithm for fault location on VSC-HVDC system
    Hao, Yongqi
    Wang, Qian
    Li, Yanan
    Song, Wenfeng
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 94 : 116 - 123
  • [5] Wavelet-based EMTR method for fault location of VSC-HVDC transmission lines
    Zhang, Xipeng
    Tai, Nengling
    Zheng, Xiaodong
    Huang, Wentao
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 961 - 966
  • [6] Single-End Based Fault Location Method for VSC-HVDC Transmission Systems
    Elgamasy, Mahmoud M.
    Izzularab, Mohamed A.
    Zhang, Xiao-Ping
    IEEE ACCESS, 2022, 10 : 43129 - 43142
  • [7] Stacked Auto-Encoder Based Fault Location in VSC-HVDC
    Luo, Guomin
    Yao, Changyuan
    Liu, Yinglin
    Tan, Yingjie
    He, Jinghan
    Wang, Kai
    IEEE ACCESS, 2018, 6 : 33216 - 33224
  • [8] VSC-HVDC transmission line fault location based on transient characteristics
    Zhang, Yanxia
    BIo, Anlu
    Wang, Jian
    Zhang, Fuhe
    Lu, Jingyi
    ARCHIVES OF ELECTRICAL ENGINEERING, 2021, 70 (02) : 381 - 398
  • [9] A novel fault detection method for VSC-HVDC transmission system of offshore wind farm
    Niaki, S. H. Ashrafi
    Karegar, H. Kazemi
    Monfared, M. Ghalei
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 73 : 475 - 483
  • [10] Analysis of Fault Characteristics of Converter in VSC-HVDC
    Sun, Xiaoyun
    Gao, Xin
    Ji, Shengchang
    Song, Ying
    2016 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2016, : 457 - 462