Fire resistance of loadbearing steel-stud walls protected with gypsum board: A review

被引:40
作者
Alfawakhiri, F [1 ]
Sultan, MA
MacKinnon, DH
机构
[1] Canadian Steel Construct Council, Toronto, ON, Canada
[2] Natl Res Council Canada, Ottawa, ON, Canada
关键词
fire resistance; loadbearing wall; cold-formed steel; stud; gypsum board;
D O I
10.1023/A:1015401029995
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
With the increased use of cold-formed lightweight steel framing (LSF), there is growing demand for the proper assessment of its performance in building fires. In partnership with the North American steel industry, the National Research Council of Canada (NRC) is conducting an experimental and analytical study on the fire resistance of loadbearing cold-formed steel-framed wall and floor assemblies. As part of this collaboration, this literature survey summarizes the information available on topics related to the fire resistance of loadbearing cold-formed steel stud walls clad with gypsum board. The current practice of establishing their fire-resistance rating, based on full-scale furnace tests, is assessed. Previous experimental and analytical studies on the subject and on the thermal and mechanical properties of the constituent materials-steel, gypsum board, and insulation-at elevated temperatures are also discussed. Future research needs are identified in the context of recent performance-based fire safety engineering concepts.
引用
收藏
页码:308 / 335
页数:28
相关论文
共 44 条
[1]  
ALEXANDER B, 1982, PHT44 RILEM COMM
[2]  
*AM IR STEEL I, 1991, LOAD RES FACT DES SP
[3]  
*AM IR STEEL I, 1996, SPEC DES COLD FORM S
[4]  
Anderberg Y., 1983, PROPERTIES MAT HIGH
[5]  
[Anonymous], P 14 INT SPEC C COLD
[6]  
[Anonymous], 1997, C3697 ASTM
[7]  
[Anonymous], 199005 SP SWED NAT T
[8]  
[Anonymous], 1989, CANULCS101M89
[9]  
*ASTM, 1995, E11995A ASTM
[10]   The modelling of dehydration and stress analysis of gypsum plasterboards exposed to fire [J].
Axenenko, O ;
Thorpe, G .
COMPUTATIONAL MATERIALS SCIENCE, 1996, 6 (03) :281-294