Comparison of learning curves and skill transfer between classical and robotic laparoscopy according to the viewing conditions:: implications for training

被引:95
作者
Blavier, Adelaide
Gaudissart, Quentin
Cadiere, Guy-Bernard
Anne-Sophie, Nyssen
机构
[1] Univ Liege, Natl Fund Sci Res, Cognit Ergon Lab, B-4000 Liege, Belgium
[2] CHU St Pierre, Dept Gastrointestinal Surg, B-1000 Brussels, Belgium
关键词
robotic surgery; depth perception; movement freedom; learning curves; laparoscopy; training;
D O I
10.1016/j.amjsurg.2006.10.014
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The purpose of this study was to evaluate the perceptual (2-dimensional [2D] vs. 3-dimensional [3D] view) and instrumental (classical vs. robotic) impacts of new robotic system on learning curves. Methods: Forty medical students without any surgical experience were randomized into 4 groups (classical laparoscopy with 3D-direct view or with 2D-indirect view, robotic system in 3D or in 2D) and repeated a laparoscopic task 6 times. After these 6 repetitions, they performed 2 trials with the same technique but in the other viewing condition (perceptive switch). Finally, subjects performed the last 3 trials with the technique they never used (technical switch). Subjects evaluated their performance answering a questionnaire (impressions of mastery, familiarity, satisfaction, self-confidence, and difficulty). Results: Our study showed better performance and improvement in 3D view than in 2D view whatever the instrumental aspect. Participants reported less mastery, familiarity, and self-confidence and more difficulty in classical laparoscopy with 2D-indirect view than in the other conditions. Conclusions: Robotic Surgery improves surgical performance and learning, particularly by 3D view advantage. However, perceptive and technical switches emphasize the need to adapt and pursue training also with traditional technology to prevent risks in conversion procedure. (c) 2007 Excerpta Medica Inc. All rights reserved.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 28 条
[1]   Can virtual reality be used to measure and train surgical skills? [J].
Arnold, P ;
Farrell, MJ .
ERGONOMICS, 2002, 45 (05) :362-379
[2]  
BIRKETT DH, 1994, SURG ENDOSC-ULTRAS, V8, P1448
[3]  
BRIDGES M, 1989, AM J SURG, V210, P118
[4]  
CADIERE GB, 1999, ENCY MED CHIRURG
[5]   Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery [J].
Chan, ACW ;
Chung, SCS ;
Yim, APC ;
Lau, JYW ;
Ng, EKW ;
Li, AKC .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (05) :438-440
[6]   COMPARISON OF DIRECT VISION AND ELECTRONIC 2-DIMENSIONAL AND 3-DIMENSIONAL DISPLAY SYSTEMS ON SURGICAL TASK EFFICIENCY IN ENDOSCOPIC SURGERY [J].
CROSTHWAITE, G ;
CHUNG, T ;
DUNKLEY, P ;
SHIMI, S ;
CUSCHIERI, A .
BRITISH JOURNAL OF SURGERY, 1995, 82 (06) :849-851
[7]   Development of a model for training and evaluation of laparoscopic skills [J].
Derossis, AM ;
Fried, GM ;
Abrahamowicz, M ;
Sigman, HH ;
Barkun, JS ;
Meakins, JL .
AMERICAN JOURNAL OF SURGERY, 1998, 175 (06) :482-487
[8]   Visual integration of data and basic motor skills under laparoscopy - Influence of 2-D and 3-D video-camera systems [J].
Dion, YM ;
Gaillard, F .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (10) :995-1000
[9]   Cumulative sum failure analysis of the learning curve with endovascular abdominal aortic aneurysm repair [J].
Forbes, TL ;
DeRose, G ;
Kribs, SW ;
Harris, KA .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (01) :102-108
[10]   Fundamental principles of validation, and reliability: rigorous science for the assessment of surgical education and training [J].
Gallagher, AG ;
Ritter, EM ;
Satava, RM .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (10) :1525-1529