Optimal image sampling schedule: A new effective way to reduce dynamic image storage space and functional image processing time

被引:38
作者
Li, XJ
Feng, DG
Chen, KW
机构
[1] UNIV SYDNEY,BASSER DEPT COMP SCI,SYDNEY,NSW 2006,AUSTRALIA
[2] GOOD SAMARITAN REG MED CTR,PET CTR,PHOENIX,AZ 85006
[3] UNIV ARIZONA,DEPT RADIOL,TUCSON,AZ 85721
基金
澳大利亚研究理事会;
关键词
D O I
10.1109/42.538948
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper, an optimal image sampling schedule for tracer dynamic studies with positron emission tomography (PET) is proposed. This schedule incorporates the characteristics of PET measurement and uses a new cost function and the D-optimal criterion. A detailed case study of the estimation of the local cerebral metabolic rate of glucose (LCMRGLc) using the tracer fluorodeoxyglucose (FDG) and the four-parameter FDG model is presented. As the sampling schedule designed requires only four dynamic images, the storage space and data processing time are greatly reduced, while the precision of the parameter estimates is almost the same as that achieved with a commonly used schedule. The effects of intersubject and intrasubject parameter variations on parameter estimation with the use of this optimal sampling schedule are investigated by computer simulation. The simulation results show that the estimation of parameters is sufficiently robust with respect to these intersubject and intrasubject variations. The optimal sampling schedule is quite suitable therefore for PET regional parameter estimation, as well as for image-wide parameter estimation, for different subjects.
引用
收藏
页码:710 / 719
页数:10
相关论文
共 31 条
[1]   STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY [J].
ALPERT, NM ;
ERIKSSON, L ;
CHANG, JY ;
BERGSTROM, M ;
LITTON, JE ;
CORREIA, JA ;
BOHM, C ;
ACKERMAN, RH ;
TAVERAS, JM .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) :28-34
[2]   THE EFFECTS OF MEASUREMENT ERRORS IN THE PLASMA RADIOACTIVITY CURVE ON PARAMETER-ESTIMATION IN POSITRON EMISSION TOMOGRAPHY [J].
CHEN, K ;
HUANG, SC ;
YU, DC .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09) :1183-1200
[3]   NEW ESTIMATION METHODS THAT DIRECTLY USE THE TIME ACCUMULATED COUNTS IN THE INPUT FUNCTION IN QUANTITATIVE DYNAMIC PET STUDIES [J].
CHEN, KW ;
HUANG, SC ;
FENG, DG .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) :2073-2090
[4]   OPTIMAL-DESIGN OF SAMPLING SCHEDULES FOR STUDYING GLUCOSE KINETICS WITH TRACERS [J].
COBELLI, C ;
RUGGERI, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (03) :E444-E450
[5]   A REDUCED SAMPLING SCHEDULE FOR ESTIMATING THE PARAMETERS OF THE GLUCOSE MINIMAL MODEL FROM A LABELED IVGTT [J].
COBELLI, C ;
RUGGERI, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (10) :1023-1029
[6]   OPTIMAL-DESIGN OF MULTIOUTPUT SAMPLING SCHEDULES - SOFTWARE AND APPLICATIONS TO ENDOCRINE METABOLIC AND PHARMACOKINETIC MODELS [J].
COBELLI, C ;
RUGGERI, A ;
DISTEFANO, JJ ;
LANDAW, EM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (04) :249-256
[7]   INCORPORATING PRIOR PARAMETER UNCERTAINTY IN THE DESIGN OF SAMPLING SCHEDULES FOR PHARMACOKINETIC PARAMETER-ESTIMATION EXPERIMENTS [J].
DARGENIO, DZ .
MATHEMATICAL BIOSCIENCES, 1990, 99 (01) :105-118
[8]   OPTIMAL SAMPLING TIMES FOR PHARMACOKINETIC EXPERIMENTS [J].
DARGENIO, DZ .
JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1981, 9 (06) :739-756
[9]   EXPERIMENTAL-DESIGN OPTIMIZATION - THEORY AND APPLICATION TO ESTIMATION OF RECEPTOR MODEL PARAMETERS USING DYNAMIC POSITRON EMISSION TOMOGRAPHY [J].
DELFORGE, J ;
SYROTA, A ;
MAZOYER, BM .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (04) :419-435
[10]  
DiStefano III J., 1984, PATHOPHYSIOLOGY PLAS, P15