摘要
The accurate understanding of optical properties of human tissues plays an important role in the optical diagnosis of early epithelial cancer. Many inverse models used to determine the optical properties of a tumor have assumed that the tumor was semi-infinite, which infers infinite width and length but finite thickness. However, this simplified assumption could lead to large errors for small tumor, especially at the early stages. We used a modified Monte Carlo code, which is able to simulate light transport in a layered tissue model with buried tumor-like targets, to investigate the validity of the semi-infinite tumor assumption in two common epithelial tissue models: a squamous cell carcinoma (SCC) tissue model and a basal cell carcinoma (BCC) tissue model. The SCC tissue model consisted of three layers, i.e. the top epithelium, the middle tumor and the bottom stroma. The BCC tissue model also consisted of three layers, i.e. the top epidermis, the middle tumor and the bottom dermis. Diffuse reflectance was simulated for two common fiber-optic probes. In one probe, both source and detector fibers were perpendicular to the tissue surface; while in the other, both fibers were tilted at 45 degrees relative to the normal axis of the tissue surface. It was demonstrated that the validity of the semi-infinite tumor model depends on both the fiber-optic probe configuration and the tumor dimensions. Two look-up tables, which relate the validity of the semi-infinite tumor model to the tumor width in terms of the source-detector separation, were derived to guide the selection of appropriate tumor models and fiber optic probe configuration for the optical diagnosis of early epithelial cancers. (C) 2011 Optical Society of America
引用
收藏
页码:17799 / 17812
页数:14
相关论文
共 27 条
  • [21] Verification of a two-layer inverse Monte Carlo absorption model using multiple source-detector separation diffuse reflectance spectroscopy
    Sharma, Manu
    Hennessy, Ricky
    Markey, Mia K.
    Tunnell, James W.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 40 - 53
  • [22] A hybrid method for fast Monte Carlo simulation of diffuse reflectance from a multi-layered tissue model with tumor-like heterogeneities
    Zhu, Caigang
    Liu, Quan
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXIII, 2012, 8221
  • [23] MONTE-CARLO STUDY OF ELECTRON-SPECTRA PRODUCED IN SEMI-INFINITE AND FINITE WATER PHANTOMS IRRADIATED BY PHOTONS OF ENERGIES UP TO 2 MEV
    PANDEY, LN
    RUSTGI, ML
    LONG, SAT
    HEALTH PHYSICS, 1987, 53 (02): : 163 - 174
  • [24] Semi-infinite mixed spin-1/2 and spin-5/2 Blume–Capel model by renormalization group theory and Monte Carlo simulation
    A. El Antari
    N. Hachem
    A. Al-Rajhi
    M. Madani
    M. El Bouziani
    The European Physical Journal Plus, 135
  • [25] Semi-infinite mixed spin-1/2 and spin-5/2 Blume-Capel model by renormalization group theory and Monte Carlo simulation
    El Antari, A.
    Hachem, N.
    Al-Rajhi, A.
    Madani, M.
    El Bouziani, M.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2020, 135 (06):
  • [26] Non-contact optical spectroscopy for tumor-sensitive diffuse reflectance and fluorescence measurements on murine subcutaneous tissue models: Monte Carlo modeling and experimental validations
    Hasan, Md Zahid
    Saha, Pranto Soumik
    Korfhage, Madison O.
    Zhu, Caigang
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (10) : 5418 - 5439
  • [27] Monte Carlo lookup table-based inverse model for extracting optical properties from tissue-simulating phantoms using diffuse reflectance spectroscopy
    Hennessy, Ricky
    Lim, Sam L.
    Markey, Mia K.
    Tunnell, James W.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (03)