Microfluidics at the crossroad with point-of-care diagnostics

被引:46
作者
Linder, Vincent
机构
[1] Claros Diagnostics, Inc., Woburn
关键词
D O I
10.1039/b706347d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microfluidic devices have been long advertised as a key candidate to revolutionize point-of-care (POC) diagnostics. Recent advances in this field have addressed some of the most important issues, which limited the deployment of microfluidic devices outside of clinical laboratories. This contribution discusses important technical and economic constraints that microfluidic products must overcome to be adopted by healthcare systems. Two sets of technologies are described which comply with the constraints of the POC environment. As such, these technologies illustrate a possible route for the development of microfluidic devices, which could fulfil the needs of clinicians for disease staging and monitoring.
引用
收藏
页码:1186 / 1192
页数:7
相关论文
共 13 条
[1]  
BURGESS DCH, 2006, NATURE S, V1, P1
[2]   Lab-on-a-chip devices for global health: Past studies and future opportunities [J].
Chin, Curtis D. ;
Linder, Vincent ;
Sia, Samuel K. .
LAB ON A CHIP, 2007, 7 (01) :41-57
[3]  
*COMM CLAR DIAGN I, 2004, DIAGNOSTIC INSTRUMEN
[4]   Reagent-loaded cartridges for valveless and automated fluid delivery in microfluidic devices [J].
Linder, V ;
Sia, SK ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2005, 77 (01) :64-71
[5]   Lab on a CD [J].
Madou, Marc ;
Zoval, Jim ;
Jia, Guangyao ;
Kido, Horacio ;
Kim, Jitae ;
Kim, Nahui .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2006, 8 :601-628
[6]   PLANAR CHIPS TECHNOLOGY FOR MINIATURIZATION AND INTEGRATION OF SEPARATION TECHNIQUES INTO MONITORING SYSTEMS - CAPILLARY ELECTROPHORESIS ON A CHIP [J].
MANZ, A ;
HARRISON, DJ ;
VERPOORTE, EMJ ;
FETTINGER, JC ;
PAULUS, A ;
LUDI, H ;
WIDMER, HM .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :253-258
[7]   From micro- to nanofabrication with soft materials [J].
Quake, SR ;
Scherer, A .
SCIENCE, 2000, 290 (5496) :1536-1540
[8]   Microfluidic technologies in clinical diagnostics [J].
Schulte, TH ;
Bardell, RL ;
Weigl, BH .
CLINICA CHIMICA ACTA, 2002, 321 (1-2) :1-10
[9]   An integrated approach to a portable and low-cost immunoassay for resource-poor settings [J].
Sia, SK ;
Linder, V ;
Parviz, BA ;
Siegel, A ;
Whitesides, GM .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (04) :498-502
[10]   Micro total analysis systems. Recent developments [J].
Vilkner, T ;
Janasek, D ;
Manz, A .
ANALYTICAL CHEMISTRY, 2004, 76 (12) :3373-3385