Hollow-fiber liquid-liquid-solid micro-extraction of lead in soft drinks and determination by graphite furnace atomic absorption spectrometry

被引:24
作者
Carletto, Jeferson S. [1 ]
Carasek, Eduardo [1 ]
Welz, Bernhard [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
Polypropylene microporous membrane; Micro-extraction; Lead determination; GF AAS; Multivariate designs; CLOUD POINT EXTRACTION; ENVIRONMENTAL-SAMPLES; MEMBRANE EXTRACTION; WATER SAMPLES; PRECONCENTRATION; CADMIUM;
D O I
10.1016/j.talanta.2011.03.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel hollow-fiber liquid-liquid-solid micro-extraction technique based on simultaneous liquid-liquid micro-extraction and solid phase micro-extraction using a polypropylene microporous membrane has been developed. The applicability of the proposed procedure was evaluated by extraction of Pb(II) from aqueous solutions and soft drinks. The parameters affecting the extraction efficiency were optimized using multivariate methodology, and the analytical features were established. Under optimized conditions, Pb(II) was concentrated for 20min on three microporous membrane hollow fibers of 6mm of length each, placed into 20mL of sample containing 60 mu L of toluene and ammonium O,O-diethyl dithiophosphate. The fibers were introduced directly into the graphite furnace as a solid sample, and the analyte was thermally desorbed from the fiber and atomized using ruthenium as a permanent modifier. A detection limit of 7ngL(-1) Pb was obtained for soft drink samples and good repeatability was found for all samples. The enrichment factor varied between 22 and 66, depending if only one or all three hollow fibers were used for the determination of lead. The results suggest that the proposed procedure represents a simple and low-cost micro-extraction alternative rendering adequate limits of quantification for the determination of Pb(II) in soft drink samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:989 / 994
页数:6
相关论文
共 21 条
  • [1] Temperature-controlled ionic liquid-liquid-phase microextraction for the pre-concentration of lead from environmental samples prior to flame atomic absorption spectrometry
    Bai, Huahua
    Zhou, Qingxiang
    Xie, Guohong
    Xiao, Junping
    [J]. TALANTA, 2010, 80 (05) : 1638 - 1642
  • [2] Simple hollow fiber renewal liquid membrane extraction method for pre-concentration of Cd(II) in environmental samples and detection by Flame Atomic Absorption Spectrometry
    Carletto, Jeferson Schneider
    Luciano, Raquel Medeiros
    Bedendo, Gizelle Cristina
    Carasek, Eduardo
    [J]. ANALYTICA CHIMICA ACTA, 2009, 638 (01) : 45 - 50
  • [3] Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction
    Chen, JR
    Xiao, SM
    Wu, XH
    Fang, KM
    Liu, WH
    [J]. TALANTA, 2005, 67 (05) : 992 - 996
  • [4] Noble metals as permanent chemical modifiers for the determination of mercury in environmental reference materials using solid sampling graphite furnace atomic absorption spectrometry and calibration against aqueous standards
    da Silva, AF
    Welz, B
    Curtius, AJ
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) : 2031 - 2045
  • [5] Preconcentration and determination of trace amounts of lead (III) as thenoyltrifluoroacetone complex with dibenzo-18-crown-6 by synergistic extraction and atomic absorption spectrometry
    Hossain, KZ
    Honjo, T
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (05): : 451 - 454
  • [6] Determination of cadmium and lead in cetacean Dolphinidae tissue from the coast of Bahia state in Brazil by GFAAS
    Korn, Maria Gracas A.
    dos Santos, Gabriel Luiz
    Rosa, Suzana M.
    Teixeira, Leonardo S. G.
    de Oliveira, Pedro V.
    [J]. MICROCHEMICAL JOURNAL, 2010, 96 (01) : 12 - 16
  • [7] Determination of trace lead in water samples by graphite furnace atomic absorption spectrometry after preconcentration with nanometer titanium dioxide immobilized on silica gel
    Liu, Rui
    Liang, Pei
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (01) : 166 - 171
  • [8] Isolation and preconcentration of Cd(II) from environmental samples using polypropylene porous membrane in a hollow fiber renewal liquid membrane extraction procedure and determination by FAAS
    Luciano, Raquel Medeiros
    Bedendo, Gizelle Cristina
    Carletto, Jeferson Schneider
    Carasek, Eduardo
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 177 (1-3) : 567 - 572
  • [9] Manahan S.E., 1994, Environmental Chemistry, V6th
  • [10] Ultra-trace determination of lead in water and food samples by using ionic liquid-based single drop microextraction-electrothermal atomic absorption spectrometry
    Manzoori, Jamshid L.
    Amjadi, Mohammad
    Abulhassani, Jafar
    [J]. ANALYTICA CHIMICA ACTA, 2009, 644 (1-2) : 48 - 52