Validation of two accelerated 4D flow MRI sequences at 3 T: a phantom study

被引:15
作者
Ebel, Sebastian [1 ]
Huebner, Lisa [1 ]
Koehler, Benjamin [2 ]
Kropf, Siegfried [3 ]
Preim, Bernhard [2 ]
Jung, Bernd [4 ]
Grothoff, Matthias [1 ]
Gutberlet, Matthias [1 ]
机构
[1] Univ Leipzig, Dept Diagnost & Intervent Radiol, Heart Ctr, Leipzig Strumpellstr 39, D-04289 Leipzig, Germany
[2] Univ Magdeburg, Dept Simulat & Graph, Magdeburg, Germany
[3] Univ Magdeburg, Inst Biometr & Med Informat, Magdeburg, Germany
[4] Univ Bern, Dept Diagnost Intervent & Paediat Radiol, Bern, Switzerland
关键词
Four-dimensional (4D) flow; Magnetic resonance imaging; Reproducibility of results; Phantoms (imaging); Pulsatile flow; PHASE-CONTRAST FLOW; BLOOD-FLOW; PC-MRI; WHOLE-HEART; IN-VITRO; TIME; QUANTIFICATION; STRATEGIES; VESSELS; NOISE;
D O I
10.1186/s41747-019-0089-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Four-dimensional (4D) flow magnetic resonance imaging (MRI) sequences with advanced parallel imaging have the potential to reduce scan time with equivalent image quality and accuracy compared with standard two-dimensional (2D) flow MRI. We compared 4D flow to standard 2D flow sequences using a constant and pulsatile flow phantom at 3 T. Methods Two accelerated 4D flow sequences (GRAPPA2 and k-t-GRAPPA5) were evaluated regarding the concordance of flow volumes, flow velocities, and reproducibility as well as dependency on measuring plane and velocity encoding (V-enc). The calculated flow volumes and peak velocities of the phantom were used as reference standard. Flow analysis was performed using the custom-made software "Bloodline". Results No significant differences in flow volume were found between the 2D, both 4D flow MRI sequences, and the pump reference (p = 0.994) or flow velocities (p = 0.998) in continuous and pulsatile flow. An excellent correlation (R = 0.99-1.0) with a reference standard and excellent reproducibility of measurements (R = 0.99) was achieved for all sequences. A V-enc overestimated by up to two times had no impact on flow measurements. However, misaligned measuring planes led to an increasing underestimation of flow volume and mean velocity in 2D flow accuracy, while both 4D flow measurements were not affected. Scan time was significantly shorter for k-t-GRAPPA5 (1:54 +/- 0:01 min, mean +/- standard deviation) compared to GRAPPA2 (3:56 +/- 0:02 min) (p = 0.002). Conclusions Both 4D flow sequences demonstrated equal agreement with 2D flow measurements, without impact of V-enc overestimation and plane misalignment. The highly accelerated k-t-GRAPPA5 sequence yielded results similar to those of GRAPPA2.
引用
收藏
页数:12
相关论文
共 33 条
  • [1] Analysis of noise in phase contrast MR imaging
    Andersen, AH
    Kirsch, JE
    [J]. MEDICAL PHYSICS, 1996, 23 (06) : 857 - 869
  • [2] ON-LINE VOLUME FLOW-RATE AND VELOCITY PROFILE MEASUREMENT FOR BLOOD IN MICROVESSELS
    BAKER, M
    WAYLAND, H
    [J]. MICROVASCULAR RESEARCH, 1974, 7 (01) : 131 - 143
  • [3] Bock J., 2007, Proceeding of International Society for Magnetic Resonance in Medicine, P3138
  • [4] In Vivo Noninvasive 4D Pressure Difference Mapping in the Human Aorta: Phantom Comparison and Application in Healthy Volunteers and Patients
    Bock, Jelena
    Frydrychowicz, Alex
    Lorenz, Ramona
    Hirtler, Daniel
    Barker, Alex J.
    Johnson, Kevin M.
    Arnold, Raoul
    Burkhardt, Hans
    Hennig, Juergen
    Markl, Michael
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (04) : 1079 - 1088
  • [5] BLOOD-FLOW MEASUREMENT USING VARIABLE VELOCITY ENCODING IN THE RR INTERVAL
    BUONOCORE, MH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) : 790 - 795
  • [6] 4D flow cardiovascular magnetic resonance consensus statement
    Dyverfeldt, Petter
    Bissell, Malenka
    Barker, Alex J.
    Bolger, Ann F.
    Carlhall, Carl-Johan
    Ebbers, Tino
    Francios, Christopher J.
    Frydrychowicz, Alex
    Geiger, Julia
    Giese, Daniel
    Hope, Michael D.
    Kilner, Philip J.
    Kozerke, Sebastian
    Myerson, Saul
    Neubauer, Stefan
    Wieben, Oliver
    Markl, Michael
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [7] MAGNETIC-RESONANCE-IMAGING OF BLOOD-FLOW WITH A PHASE SUBTRACTION TECHNIQUE - INVITRO AND INVIVO VALIDATION
    EVANS, AJ
    IWAI, F
    GRIST, TA
    SOSTMAN, HD
    HEDLUND, LW
    SPRITZER, CE
    NEGROVILAR, R
    BEAM, CA
    PELC, NJ
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (02) : 109 - 115
  • [8] Comparison of fast acquisition strategies in whole-heart four-dimensional flow cardiac MR: Two-center, 1.5 Tesla, phantom and in vivo validation study
    Garg, Pankaj
    Westenberg, Jos J. M.
    van den Boogaard, Pieter J.
    Swoboda, Peter P.
    Aziz, Rahoz
    Foley, James R. J.
    Fent, Graham J.
    Tyl, F. G. J.
    Coratella, L.
    ElBaz, Mohammed S. M.
    van der Geest, R. J.
    Higgins, David M.
    Greenwood, John P.
    Plein, Sven
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (01) : 272 - 281
  • [9] Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
    Gatehouse, PD
    Keegan, J
    Crowe, LA
    Masood, S
    Mohiaddin, RH
    Kreitner, KF
    Firmin, DN
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (10) : 2172 - 2184
  • [10] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210