共 35 条
Two Cannulated Screws Provide Sufficient Biomechanical Strength for Prophylactic Fixation in Adult Patients With an Aggressive Benign Femoral Neck Lesion
被引:5
作者:
Fu, Guangtao
[1
]
Zhong, Guoqing
[1
,2
]
Yang, Zehong
[3
]
Cheng, Shi
[1
]
Ma, Limin
[1
]
Zhang, Yu
[1
]
机构:
[1] Guangdong Acad Med Sci, Guangdong Prov Peoples Hosp, Dept Orthoped, Guangzhou, Peoples R China
[2] Shantou Univ Med Coll, Shantou, Peoples R China
[3] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Dept Radiol, Guangzhou, Peoples R China
关键词:
femoral neck;
benign lesion;
cannulated screw;
prophylactic fixation;
biomechanical analysis;
FINITE-ELEMENT;
PATHOLOGICAL FRACTURES;
CEMENT AUGMENTATION;
CORTICAL BONE;
FEMUR;
HEAD;
D O I:
10.3389/fbioe.2022.891338
中图分类号:
Q81 [生物工程学(生物技术)];
Q93 [微生物学];
学科分类号:
071005 ;
0836 ;
090102 ;
100705 ;
摘要:
Background: Two cannulated screws were proposed for prophylactic fixation in adult patients with an aggressive benign femoral neck lesion in recent literature. However, the biomechanical properties of this intervention have not yet been investigated.Methods: After the evaluation of the heterogeneity of bone mineral density and geometry via quantitative computed tomography, 24 embalmed adult human cadaver femurs were randomized into the control, inferior half of the anterior cortical (25%) bone defect, entire anterior cortical (50%) bone defect, and the 50% bone defect and two cannulated screw group. Biomechanical analysis was conducted to compare the stiffness and failure load among the four groups when mimicking a one-legged stance. A CT-based finite element analysis (FEA) was performed to mimic the cortical and cancellous bone defect and the implantation of two cannulated screws of the four groups. Measurements of the maximal displacement and von Mises stress were conducted with the longitudinal load force and boundary conditions being established for a one-leg-standing status.Results: We noted a significant improvement in the failure load after the insertion of two 6.5 mm cannulated screws in femurs with 50% bone defect (+95%, p = 0.048), and no significant difference was found between the screw group and the intact femur. Similar trends were also found in the measurements of stiffness (+23%, p > 0.05) via biomechanical testing and the von Mises stresses (-71%, p = 0.043) by FEA when comparing the screw group and the 50% bone defect group.Conclusion: Our findings suggest that two cannulated screws provided sufficient biomechanical strength for prophylactic fixation in adult patients with an aggressive benign femoral neck lesion even when the entire anterior cortical bone is involved.