Two Cannulated Screws Provide Sufficient Biomechanical Strength for Prophylactic Fixation in Adult Patients With an Aggressive Benign Femoral Neck Lesion

被引:5
作者
Fu, Guangtao [1 ]
Zhong, Guoqing [1 ,2 ]
Yang, Zehong [3 ]
Cheng, Shi [1 ]
Ma, Limin [1 ]
Zhang, Yu [1 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Prov Peoples Hosp, Dept Orthoped, Guangzhou, Peoples R China
[2] Shantou Univ Med Coll, Shantou, Peoples R China
[3] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Dept Radiol, Guangzhou, Peoples R China
关键词
femoral neck; benign lesion; cannulated screw; prophylactic fixation; biomechanical analysis; FINITE-ELEMENT; PATHOLOGICAL FRACTURES; CEMENT AUGMENTATION; CORTICAL BONE; FEMUR; HEAD;
D O I
10.3389/fbioe.2022.891338
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: Two cannulated screws were proposed for prophylactic fixation in adult patients with an aggressive benign femoral neck lesion in recent literature. However, the biomechanical properties of this intervention have not yet been investigated.Methods: After the evaluation of the heterogeneity of bone mineral density and geometry via quantitative computed tomography, 24 embalmed adult human cadaver femurs were randomized into the control, inferior half of the anterior cortical (25%) bone defect, entire anterior cortical (50%) bone defect, and the 50% bone defect and two cannulated screw group. Biomechanical analysis was conducted to compare the stiffness and failure load among the four groups when mimicking a one-legged stance. A CT-based finite element analysis (FEA) was performed to mimic the cortical and cancellous bone defect and the implantation of two cannulated screws of the four groups. Measurements of the maximal displacement and von Mises stress were conducted with the longitudinal load force and boundary conditions being established for a one-leg-standing status.Results: We noted a significant improvement in the failure load after the insertion of two 6.5 mm cannulated screws in femurs with 50% bone defect (+95%, p = 0.048), and no significant difference was found between the screw group and the intact femur. Similar trends were also found in the measurements of stiffness (+23%, p > 0.05) via biomechanical testing and the von Mises stresses (-71%, p = 0.043) by FEA when comparing the screw group and the 50% bone defect group.Conclusion: Our findings suggest that two cannulated screws provided sufficient biomechanical strength for prophylactic fixation in adult patients with an aggressive benign femoral neck lesion even when the entire anterior cortical bone is involved.
引用
收藏
页数:9
相关论文
共 35 条
[11]   Large femoral-neck cysts in association with femoroacetabular impingement - A report of three cases [J].
Guenther, Klaus-Peter ;
Hartmann, Albrecht ;
Aikele, Peter ;
Aust, Daniela ;
Ziegler, Joerg .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) :863-870
[12]   Comparative study of multiple cancellous screws versus sliding hip screws in femoral neck fractures of young adults [J].
Gupta, Mayank ;
Arya, Rajendra Kumar ;
Kumar, Satish ;
Jain, Vijay Kumar ;
Sinha, Skand ;
Naik, Ananta Kumar .
CHINESE JOURNAL OF TRAUMATOLOGY, 2016, 19 (04) :209-212
[13]   Is the Cranial and Posterior Screw of the "Inverted Triangle" Configuration for Femoral Neck Fractures Safe? [J].
Hoffmann, Jacob C. ;
Kellam, James ;
Kumaravel, Manickam ;
Clark, Kurt ;
Routt, Milton L. Chip ;
Gary, Joshua L. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (07) :331-334
[14]   Impending fractures in giant cell tumours of the distal femur: incidence and outcome [J].
Jeys, LM ;
Suneja, R ;
Chami, G ;
Grimer, RJ ;
Carter, SR ;
Tillman, RM .
INTERNATIONAL ORTHOPAEDICS, 2006, 30 (02) :135-138
[15]   Biomechanical comparison of five cannulated screw fixation strategies for young vertical femoral neck fractures [J].
Jiang, Dajun ;
Zhan, Shi ;
Wang, Lei ;
Shi, Lewis L. ;
Ling, Ming ;
Hu, Hai ;
Jia, Weitao .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (08) :1669-1680
[16]   Importance of asymmetry and anisotropy in predicting cortical bone response and fracture using human body model femur in three-point bending and axial rotation [J].
Khor, F. ;
Cronin, D. S. ;
Watson, B. ;
Gierczycka, D. ;
Malcolm, S. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 87 :213-229
[17]   Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble? [J].
Krastman, Patrick ;
van den Bent, Rob P. ;
Krijnen, Pieta ;
Schipper, Inger B. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (05) :297-303
[18]   Lateral Cortical Thickening and Bone Heterogeneity of the Subtrochanteric Femur Measured With Quantitative CT as Indicators for Early Detection of Atypical Femoral Fractures in Long-Term Bisphosphonate Users [J].
Lee, Seung Hyun ;
Lee, Young Han ;
Suh, Jin-Suck .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (04) :867-873
[19]   Rib fractures under anterior-posterior dynamic loads: Experimental and finite-element study [J].
Li, Zuoping ;
Kindig, Matthew W. ;
Kerrigan, Jason R. ;
Untaroiu, Costin D. ;
Subit, Damien ;
Crandall, Jeff R. ;
Kent, Richard W. .
JOURNAL OF BIOMECHANICS, 2010, 43 (02) :228-234
[20]   Comparison of Femoral Morphology and Bone Mineral Density between Femoral Neck Fractures and Trochanteric Fractures [J].
Maeda, Yuki ;
Sugano, Nobuhiko ;
Saito, Masanobu ;
Yonenobu, Kazuo .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (03) :884-889